Norte Parque Industrial Valle Grande, Lampa Santiago, Chile TEL: 02-270-8600 FAX: 02-270-8601 SWEDEN SMC Pneumatics Sweden AB Ekhagsvgen 29-31, S-141 05 Huddinge, Sweden TEL: 08-603-07-00 FAX: 08-603-07-10 ARGENTINA SMC Argentina S.A.
[pulse] 10 [pulse] 0 0 10 [pulse] 10 [pulse] -10 [V] -10 [V] CW direction CW direction App. 20 APPENDIX Setting value Output item Description Setting value Output item Description 0A Feedback position (Note 1, 2, 3) (10 V/1 Mpulse) 0B Feedback position (Note 1, 2, 3) (10 V/10 Mpulse) CCW direction CCW direction 10 [V] 10 [V] 1 [Mpulse] 10 [Mpulse] 0 0 1 [Mpulse] 10 [Mpulse] -10 [V] -10 [V
Auto switch model Bore size (mm) Operating Range 100 20 25 32 40 50 63 80 D-C7/C80 D-C73C/C80C D-B5/B64 11 10 10 9 10 8 11 17 10 14 10 14 9 14 10 13 8 13 11 16 11 18 D-B59W D-M9, M9W D-M9A 6.5 6 5 4.5 4 4 Since this is a guideline including hysteresis, not meant to be guaranteed.
0.3 Encoder Cable (Note 3) ETFE SVP 70/0.08 (AWG#22 or equivalent)-3P Ban-gi-shi-16824 LE-CSE-RB LE-CSE-RA 2 to 10 AWG22 6 (3 pairs) 70/0.08 56 or less 1.2 7.1 0.3 LE-CSM-SA 2 to 10 AWG18 4 34/0.18 21.8 or less 1.71 62 0.3 HRZFEV-A(CL3) AWG18 4-cores LE-CSM-SB 2 to 10 Motor cable LE-CSM-RA 2 to 10 (Note 5) AWG19 or less 1.63 5.7 0.5 (Note 4) RMFES-A(CL3X) AWG19 4-cores LE-CSM-RB 2 to 10
Applicable model HRR012/018--10-T/MT*1 HRR012/018/024/030--20-T HRR012/018/024/030--20-MT1 Pump Rated flow (50/60 Hz)2, 3 L/min 7 (0.36 MPa)/10 (0.42 MPa) 10 (0.42 MPa)/14 (0.40 MPa) 10 (0.32 MPa)/14 (0.32 MPa) Maximum pump head (50/60 Hz) m 50 50 50 Output W 350 550 Circuit protector A 15 15 (10 A for standard) Recommended earth leakage breaker capacity A 15 Cooling capacity4 W The cooling
Norte Parque Industrial Valle Grande, Lampa Santiago, Chile TEL: 02-270-8600 FAX: 02-270-8601 SWEDEN SMC Pneumatics Sweden AB Ekhagsvgen 29-31, S-141 05 Huddinge, Sweden TEL: 08-603-07-00 FAX: 08-603-07-10 ARGENTINA SMC Argentina S.A.
Stations 02 Symbol Port size Applicable series 1/4 3/8 1/2 02 03 04 VPA300 VPA500 VPA700 2 stations 20 20 stations Manifold Option Description Part no.
Z type 24 VDC: 7% to +10% 12 VDC: 4% to +10% T type 24 VDC: 5% to +10% 12 VDC: 6% to +10% Serial wiring: EX180 Response Time Type of actuation Response time ms (at 0.5 MPa) SJ2000 SJ3000 2 position single 2 position double 3 position 4 position dual 3 port valve 16 or less 10 or less 34 or less 30 or less 16 or less 10 or less 22 or less 30 or less Gateway system Serial transmission system
(mm) Connection thread Rc T (M) Width across flat M Weight (g) Mounting hole L1 L2 Model H1 H2 KQB2E23-02 KQB2E04-01 KQB2E04-02 KQB2E06-01 KQB2E06-02 KQB2E06-03 KQB2E08-01 KQB2E08-02 KQB2E08-03 KQB2E10-02 KQB2E10-03 KQB2E12-03 KQB2E12-04 KQB2E16-03 KQB2E16-04 3.2 3.4 1/4 1/8 1/4 1/8 1/4 3/8 1/8 1/4 3/8 1/4 3/8 3/8 1/2 3/8 1/2 17 14 17 11 12 31 25.8 30.9 24.2 31.6 33 26.3 32.4 34 31.6 33.6
Bonnet Common IN Individual IN Common IN Individual IN Polyacetal 2 Regulator Regulator ARM2500-A-02 ARM2500-B-02 ARM3000-A-03 ARM3000-B-03 9 1 Replacement Parts End plate R 10 1 Description Material Part no. End plate L 11 1 No.
Blow Velocity Distribution (Supply Pressure: 0.3 MPa) qEnergy saving static neutralization nozzle IZN10E-01 wHigh flow rate nozzle IZN10E-02 0 0 100 100 Distance [mm] Distance [mm] 200 200 4 m/s 14 m/s 300 300 11 m/s 3 m/s 400 400 8 m/s 2 m/s 500 30 30 20 10 0 10 20 500 30 30 20 10 0 10 20 Distance (Horizontal) [mm] Distance (Horizontal) [mm] 8 IZN10E Series Flow Rate Characteristics qEnergy
15.2 40.4 35.4 15 18.5 11 R 1/4 17 34.4 29.4 55 18.5 46.5 28.2 19.7 10 ASD430F-02-10S 18.5 58 21 49.3 31 6 ASD530F-02-06S 12.8 74 17 48.3 25.2 20.3 8 ASD530F-02-08S 15.2 76 18.5 51.3 28.2 41.9 46.9 48.8 43.8 19.8 23 15.4 R 1/4 19 42.8 37.8 10 ASD530F-02-10S 18.5 80 21 54.1 32.6 23.1 12 ASD530F-02-12S 83 20.9 22 55.9 34.4 6 ASD530F-03-06S 74 17 12.8 48.3 25.2 20.3 8 ASD530F-03-08S 93 18.5
41.7 40.4 35.4 15.2 18.5 15 11 R(PT)1/4 17 34.4 29.4 18.5 55 28.2 46.5 19.7 10 ASD430F-02-10S 18.5 21 58 31 49.3 6 ASD530F-02-06S 12.8 17 74 25.2 48.3 20.3 8 ASD530F-02-08S 15.2 18.5 76 28.2 51.3 41.9 46.9 48.8 43.8 23 19.8 15.4 R(PT)1/4 19 42.8 37.8 10 ASD530F-02-10S 21 18.5 80 32.6 54.1 23.1 12 ASD530F-02-12S 22 20.9 83 34.4 55.9 6 ASD530F-03-06S 17 74 12.8 25.2 48.3 20.3 8 ASD530F-03-08S
CC-Link (P.77) 4.2 (P.18)4.3 PLC (P.18)PLC 10 - 8() ()() () 9 10. (P.32) PLC 14.
Please refer to 10. Memory map for details of each signal.
-5 Gasket DXT192-10-5 (Use caution to the orientation.)
Norte Parque Industrial Valle Grande, Lampa Santiago, Chile TEL: 02-270-8600 FAX: 02-270-8601 SWEDEN SMC Pneumatics Sweden AB Ekhagsvgen 29-31, S-141 05 Huddinge, Sweden TEL: 08-603-07-00 FAX: 08-603-07-10 ARGENTINA SMC Argentina S.A.
Inch size Metric size Port size 4 04 03 5/32 M5 M5 x 0.8 Thread type 6 06 07 1/4 U10/32 10-32 UNF 8 08 09 5/16 Metric thread (M5) 01 1/8 Nil 10 10 11 3/8 Unified thread (10-32 UNF) 02 1/4 12 12 13 1/2 R 03 3/8 N NPT 04 1/2 Check valve free flow direction Applicable Tubing O.D./Port Size Combinations From male thread to One-touch fitting A Metric size Inch size Applicable tubing O.D.
D-M9A D-M9V Qty. of auto switches mounted D-A9 D-M9 D-P3DW Note 1) 5 10(5) 15 (10) 15 (5) 1 pc. 10 15 5 10 10 15 (10) 15 (5) 2 pcs. 10 15 5 Note 1) 25 is only applicable for D-P3DW.