Actuation: 2 (Normally Open), Voltage: 5 (24 VDC), Electrical Entry: G (Grommet, Lead Wire Length 300 mm), Light/Surge Voltage Suppressor: R (w/Surge Voltage Suppressor, DC)
Actuation: 2 (Normally Open), Voltage: 5 (24 VDC), Electrical Entry: L (L Plug Connector, w/Lead Wire 300 mm)
Actuation: Normally Open, Voltage: 24 VDC, Electrical Entry: Grommet, Lead Wire Length 300 mm, Light/Surge Voltage Suppressor: w/Surge Voltage Suppressor, DC, Manual Override: -, Port Size: -
Actuation: Normally Open, Voltage: 24 VDC, Electrical Entry: L Plug Connector, w/Lead Wire 300 mm, Light/Surge Voltage Suppressor: -, Manual Override: -, Port Size: -
(Supply puressure : 0.3 to 0.5MPa) Facility water outlet port*1 Rc3/4 28 to 30Nm 1.0MPa and more Automatic fluid fill port Rc1/2 20 to 25Nm Automatic fluid -fill pressure : 0.2 to 0.5MPa Overflow port Rc1 36 to 38Nm ID25mm and more Length 5m and less Pump drain port Rc1/4 8 to 12Nm --1 : Water cooled type only.
Description Size 1 Particle filter (Accessory) filtration accuracy 5m 2 Valve 1 3 Flow meter Prepere a flow meter with an appropriate flow range. 4 Valve 1/2 Mounting of DI filter At delivery, "Temporary piping for DI filter" is connected. Install the DI filter (accessory) according to "7.4.2 Replacing the DI filter".
Description Size 1 Particle filter (Accessory) filtration accuracy 5m 2 Valve 1 3 Flow meter Prepere a flow meter with an appropriate flow range. 4 Valve 1/2 Mounting of the DI filter At delivery, "Temporary piping for DI filter" is connected. Install the DI filter (accessory) according to "7.4.2 Replacing the DI filter".
Table 3-3 Power supply cable and earth leakage breaker (Recommended) Earth leakage breaker *1 Terminal Cable Model Power supply block Recommended Sensitivity specifications Rated voltage screw crimp terminal of leakage *2 current diameter current (A) (mA) 380-415 VAC 4 x 5.5 mm2 50/60Hz 3 phase, (4 x AWG10) HRS200-A-46-S M5 R5.5-5 30 30 *Including 460-480 VAC 60Hz ground 3 phase *1.
Select an air filter with a filtration degree of 5m or finer. 3. Install an aftercooler, air dryer or drain catch before the filter and take appropriate measures. Compressed air that contains excessive foreign material may cause malfunction of valves and other pneumatic equipment.
A filtration degree of 5m or less should be selected. 3. Install an aftercooler, air dryer or drain catch before the filter and take appropriate measures. Compressed air that contains excessive foreign material may cause malfunction of valves and other pneumatic equipment.
A filtration degree of 5m or less should be selected. 3. Install an aftercooler, air dryer or drain catch before the filter and take appropriate measures. Compressed air that contains excessive foreign material may cause malfunction of valves and other pneumatic equipment.
M6x23 JMHZ2-16D D-M9N-5 M3X7 M-5ALHU-2 2 ASN2-M5-X937 M-5ALHU-2 3 V114-5LU KQ2S04-M5N 3x6 ISO9409-1 M4x25 M8 8 () 6x10 M6x10 5 - 3 3-1. 6 - 3-2. mm 16 MPa 0.1~0.7 (oC) -10~50 (mm) 0.01 (c.p.m.) 120 32.7 (N) 43.5 (mm) 10 (g) 430 M8 8 (www.smcworld.com)JMHZ2 Series P .15 M8 8 7 - 3-3. 2 1 F 8 - 3-4.
M3x7 0.59Nm 21 - 0.7mm 22 - 5-3 1. 2. 3. 4. 1.() 2. 5m 3. 4. 5 5-4. 1.
Torque Warning SGC200 M4 1.5Nm SGC300 M5 3.0Nm Cover SGC400, 500 M6 5.2Nm SGC600, 700 M8 12.5Nm Note) Tightening torque range shall be +/-10%. Body assembly Figure 1 Valve construction Figure 2 Head screw tightening procedure 4 SGC200-OMM0002-F SGC / SGH Series Coolant Valve / Precautions 2 Be sure to read this before handling. Selection Mounting 4.
Caution (1)For M3, M5, 10-32UNF Tightening method (10)Do not apply excessive force or shock to For M3 First, tighten it by hand, then give it an additional 1/6 turn to 1/4 turn with a hexagon wrench. Refer to Table below for reference. the body or fittings with an impact tool.
Select an air filter with a filtration size of 5m or smaller. 3. Take measures to ensure air quality, such as by installing an aftercooler, air dryer, or water separator. Compressed air that contains a large amount of drainage can cause malfunction of pneumatic equipment such as valves.
Solid sphere Position of rotational axis: Through the center of diameter 2 2 r I = m5 27 - Kinetic energy Table (9) shows the allowable kinetic energy of the rotary actuator. The end angular speed is obtained by: Table 9.
A filtration degree of 5m or less should be selected. 3. Install an aftercooler, air dryer or drain catch before the filter and take appropriate measures. Compressed air that contains excessive foreign material may cause malfunction of valves and other pneumatic equipment. Install an aftercooler, air dryer or drain catch before the filter and take appropriate measures. 4.
Bore size (mm) 32 40, 50, 63 80, 100 Thread size M2.5 X 0.45 X 25 l M3 X 0.5 X 30 l M5 X 0.8 X 40 l Pulling force 4.9N 10N 24.5N Stroke (mm) 2 3 3 e Release lock when mounting or adjusting the cylinder. If mounting is done with lock engaged, lock mechanism may be damaged. * Remove bolt under normal operations.
A80CN 1) Lead wire symbols 0.5m: 3m: L 5m: Z : N 2) This rotary cylinder is not an improved product in water resistant ability.