SMC Corporation of America
Elite Part Number Search
Search Results "SS5YJ7-41-04-01"

Bore size (mm) 4, 6, 8, 10 Port size M3 x 0.5 6 8 or more Stroke (mm) AS121F-M3-23 AS121F-M3-04 AS131F-M3-23 AS131F-M3-04 Only applicable to the mounting position shown in Fig. (1) below.

Service Class Inst Attr ID Values ID ID Reset 01 h [Identity Object] 1 h 01 (Type1 reset) 37 No.EX-OMS0014-A < Properties tab > Network information including the GW unit MAC address and communication speed are displayed. 38 No.EX-OMS0014-A Specification Specifications Basic Specifications Item Specifications Power supply voltage range Power supply for input and control: 24 VDC 10% Power

Function Setting 24 Function selection mode 24 Default setting 24 F0 Units selection function 26 F1 Setting of OUT1 27 F2 Setting of OUT2 30 F3 Response time 30 F4 Display resolution 31 F5 Auto-preset function 32 F6 Fine adjustment of display value 34 F7 Power saving mode 35 F8 Security code 36 Special function setting 37 F90 Setting of all functions 37 F97 Copy function 39 F98 Check of output 41

Model Elbow type Straight type In-line type 12-REA25 10-AS2001F-06-X214 10-AS2201F-01-06-X214 10-AS2301F-01-06-X214 12-REA32 10-AS2001F-06-X214 10-AS2301F-02-06-X214 10-AS2201F-02-06-X214 6. Do not use the cylinder with its body fixed. Be sure to secure both head covers (or end covers in case of CY1R) before using the cylinder.

8 75 60 4 7 18 13 37 34 8 62 15.5 13 26 30 5 8 28 5 M8 x 1.25 15 24 M20 x 1.5 1/8 116 20 0 0.033 25 45 8 75 60 4 7 22 13 41 40 10 62 19.5 17 32 37 6 8 33.5 5.5 M10 x 1.25 15 30 M26 x 1.5 120 1/8 26 0 0.033 32 45 8 75 60 4 7 22 13 41 40 12 64 19.5 17 32 37 6 8 37.5 5.5 M10 x 1.25 15 34.5 M26 x 1.5 122 1/8 26 0 0.039 40 50 11 82 36 66 5 7 24 16 45 52 14 88 21 22 41 47.3 8 10 46.5 7 M14

20 33.5 5.5 M10 X 1.25 1to450 19.5 17 32 37 6 8 M26 X 1.5 120 40 10 15 30 62 22 13 41 7 4 60 25 75 8 45 26 34.5 37.5 5.5 M10 X 1.25 1to450 19.5 17 32 37 6 8 M26 X 1.5 122 40 12 15 64 22 13 41 7 4 60 32 75 8 45 26 21 47.3 7 M14 X 1.5 21.5 M32 X 2 42.5 46.5 1to500 22 41 8 10 154 52 14 88 24 16 45 7 5 66 40 36 82 11 50 32 With rod boot (mm) ZZ Symbol h l Stroke f e Bore 1 to 50 1 to 50 1

Mass (g) D-M9NW, D-M9NWV Auto Switch Internal Circuit D-M9NW(V) D-M9PW(V) D-M9BW(V) Auto switch model 8 8 7 0.5 DC (+) Brown 14 14 13 1 Lead wire length (m) 41 41 38 3 Main circuit of switch Main circuit of switch Main circuit of switch OUT Black 68 68 63 5 Dimensions (mm) DC () Blue M2.5 x 4l Slotted set screw D-M9 W D-M9PW, D-M9PWV Indicator light 2.6 DC (+) Brown 2.7 2.8 4 OUT Black 22

A A1 L1 MM RR1 U1 NZ L A1 MM U1 L1 E1 10 12 16 20 22 28 38 44 +0.048 0 5 6.4 8 10 18 22 28 32 0.2 0.4 0.1 0.3 0.2 0.4 0.2 0.4 0.3 0.5 0.3 0.5 0.3 0.5 0.3 0.5 +0.048 0 5 6.5 8 10 18 22 28 32 21.5 28 34 41 42 56 71 79 10 21.5 32 34 41 42 56 71 79 6 8 8.5 10.5 14 18 21 21 16 25 25 30 30 40 50 55 M5 X 0.8 M6 X 1 6.3 8.1 10.3 12.8 12 16 21 24 7 14 11.5 14 14 20 27 31 6 11 8.5 16

Width across flats of attachment 3/8 20.9 mm 1/2 23.9 mm 3/4 29.9 mm 1 41 mm 11/4 54 mm 11/2 54 mm After hand tightening the piping, apply a spanner of the correct size to the spanner flats on the product, and tighten it for 2 to 3 rotations. The tightening torque is shown in the table below.

.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 6H9 +0.030 7 (Hexagon socket head taper thread plug) 0 48 98 72 41 8 Operating port Rc 1/8 25 40 40 40 (Y) (Y) 10 Operating direction (B) 6H9 +0.030 depth 5.5 0 41 160 (Hexagon socket head taper thread plug) 10.5 Operating direction (B) (A) 9.5 11 24

Width across flats 13 Operating port Rc 1/8 (NPT 1/8, G 1/8) 8 x M5 x 0.8 thread depth 13 Note) A Operating direction 6H9 + 0.030 0 depth 5.5 (Insert) 7 (Hexagon socket head taper thread plug) 48 98 72 41 10 8 25 40 40 40 Y Y Operating port Rc 1/8 (NPT 1/8, G 1/8) 41 160 B Operating direction 6H9 + 0.030 0 depth 5.5 (Hexagon socket head taper thread plug) 10.5 Operating direction B A 9.5

to Order 200 VAC 230 VAC VVX2 4 1 A 02 Flat terminal Y 24 VDC Fluid 4 Medium vacuum Z Other voltages Coil size Base material /Port size/Base type How to Order Manifold Assembly (Example) Stations Base material Base type Individual port size Special thread Stations Symbol Symbol Size Symbol Symbol Enter the valve and blanking plate to be mounted under the manifold base part number. 02 03 04

Applicable bore size B (C) (D) d H NT-02 20 13 (15.0) 12.5 M8 x 1.25 5 NT-03 25, 32 17 (19.6) 16.5 M10 x 1.25 6 NT-04 40 22 (25.4) 21.0 M14 x 1.5 8 Part no.

Location X119US Non-Rotating Oversize Rod X130US Stainless Steel Piston Rod, Tie Rod, Tie Rod Nut, Cushion Valve Needle For special rod end modifications please see page 41.

Order them separately referring to Mounting Bolt for C(D)Q2B on pages 41 and 44. Auto switch Nil Without auto switch Refer to the below table for applicable auto switches.

piping Front protective cover ZS-35-01 Bottom piping -10No.PS-OMU0009-D Summary of Product parts Names of individual parts Operation light: Displays the switch operating condition.

Description Description Note 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 No.

L d m t l IY-G012 IY-J015 IY-G02 IY-G03 IY-G04 IY-G05 IY-G08 IY-G10 NTJ-015A NT-015A NT-02 NT-03 NT-04 NT-05 NT-08 NT-10 Type C 5 for axis M5 x 0.8 M6 x 1 M8 x 1.25 M10 x 1.25 M14 x 1.5 M18 x 1.5 M22 x 1.5 M26 x 1.5 4 5 5 6 8 11 13 16 8 10 13 17 22 27 32 41 9.2 11.5 15.0 19.6 25.4 31.2 37.0 47.3 5 5 8 10 10 14 18 22 14.6 16.6 21 25.6 41.6 50.6 64 72 4.8 4.8 7.6 9.6 9.6 13.4 17 21 10.2 12.2