) (7.5) (45.9) (48) 24 M4 x 0.7, thread depth 8 (F.G. terminal) Auto switch groove (1 row per side) 6.5 38.5 48 6 B D x 120 (= E) 10 120 F 3H9 (+0.025 0 ) depth 35 Motor mounting position: Right side parallel Motor mounting position: Left side parallel 106 4 106 48 5 3H9 (+0.025 0 ) depth 35 3H9 (+0.025 0 ) depth 35 8 46 46 47 47 H G *1 When mounting the actuator using the body mounting
Thread type and port size C D E Material Number of 1 set Male thread A side Female thread B side Mounting hole dia.: 10.5 IDF-AP604 NPT1 Rc1 1.97 (50) 1.06 (27) 1.81 (46) [inch (mm)] Brass 2 IDF-AP606 NPT1 1/2 Rc1 1/2 2.17 (55) 1.22 (31) 2.13 (54) Part no.
No.LFE*-OMY0008 / / / / / / / / LFE# SMC SMC SMC SMC 2 11 13 14 16 18 19 21 24 26 26 F1 OUT1 28 F2 OUT2 36 F3 40 F10 41 F20 45 F22 46 F30 47 F32 48 F33 50 F34 51 F80 52 F81 53 F82 54 F90 55 F98 56 F99 57 58 60 61 64 66 67 70 71 1 No.LFE*-OMY0008 (ISO/IEC) (JIS) 1 2 1) ISO 4414:Pneumatic fluid power -General rules relating to systems.
06 10 06 10 90 M6 x 1 Depth 7.5 39 50 0 77 74 59 175 128 3/4, 1 46 06 10 107 06 10 94 M6 x 1 Depth 7.5 39 50 0 77 74 59 175 128 3/4, 1 46 06 10 111 5 Soft Start-up Valve AV2000/3000/4000/5000 Modular F.R.L.
18 63 M18 x 1.5 35 32 20 46 18 80 M22 x 1.5 40 37 25 51 22 100 M26 x 1.5 40 37 30 52 26 30 Series CHQB Auto Switch Specifications Auto Switches: Proper Mounting Positions and Mounting Heights for Stroke End Detection 20 32 to 100 D-A7 D-A80 Approx.
+ Stroke AA + Stroke 60 Turntable angle detection switch 2-P E (mm) Bore size (mm) FB FC G GA GB GC H HA HB J K L MM ML NN NL OA B C DA FA Standard stroke (mm) 77 96.5 116 63 80 100 20 25 30 10 12 15 39 45.5 55.5 103 121.5 145 M10 M12 M14 162 202 240 16.5 14.5 18 13.5 15.5 19 16.5 19 23 78 91.5 111.5 15 15 20 12 18 25 16 22 25 49 56.5 66 M6 X 1.0 M8 X 1.25 M8 X 1.25 22 26 32 58 54 62 39 46
06 10 06 10 90 M6 x 1 Depth 7.5 39 50 0 77 74 59 175 128 3/4, 1 46 06 10 107 06 10 94 M6 x 1 Depth 7.5 39 50 0 77 74 59 175 128 3/4, 1 46 06 10 111 5 Soft Start-up Valve AV2000/3000/4000/5000 Modular F.R.L.
Dimensions L5 D4 Applicable tubing O.D. d H (Width across flats) A L4 D1 L3 D3 L1 M D2 T L2 [mm] Model T H D1 D2 D3 D4 L1 L2 L3 L4 L5 A M Weight [g] AS221F-G01-06W2D G1/8 12 13.2 14.2 14 7.2 23 31 17.6 39.2 1.2 34.7 17 26 AS221F-G01-08W2D 15.2 25.3 32.4 18.5 28 AS221F-G01-10W2D 18.5 32.1 39.2 21 30 AS221F-G02-06W2D G1/4 17 13.2 18.5 17 7.2 25.2 34.4 20.2 42.8 1.2 36.8 17 46 AS221F-G02-08W2D
Remote type sensor unit 3 A LFE 1 Integrated display type Rated flow range Made to Order (Refer to p. 17.)
20 15 4(A) 4(A) 5 46 12.5 P=11 L plug connector (L) Dimensions n: Stations L n 19 226 218 20 237 229 13 160 152 15 182 174 17 204 196 5 72 64 6 83 75 7 94 86 9 116 108 11 138 130 L2 L1 2 39 31 3 50 42 4 61 53 16 193 185 18 215 207 10 127 119 12 149 141 14 171 163 8 105 97 601
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 60
/See 2.1 Specification P .9 to 1 1 for LEFS / See 2.2 Specification P .12, 13 for LEFB 4) The pushing operation is performed Review the content of the step data. at the Positioning operation position 46 - No. Phenomenon Cause Countermeasure 5) The cable is not connected Confirm that the cable is connected correctly. /See 4.
-11-16 17 Rotary Gripper Series MRHQ Construction MHZ MHF MHL MHR MHK Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com MHS MHC MHT MHY MHW MRHQ Misc.
Finger Bolt interferes with speed controller 2.8-17 Series MHW2 Construction Closed r !0 !9 !8 !4 u !1 !3 y !2 e q t !6 w i o !7 !5 Open Component Parts Component Parts Description Material No.
TB 18 22 W 69 115 WA 32 46 WB 17 27 Y 2.5 3.5 Z 118 155 L 67 90 Model CYP15 CYP32 Note 1) These dimension drawings indicate the case of piping port position "Nil".
27 WA 32 46 W 69 115 TB 18 22 TA 13 17 T 23 29 R 45 79.5 QW 48 87 N 4.5 7.5 Q 105 138 M 6 8 PB 60 100 MM M4 x 0.7 M6 x 1 PA 25 50 LW 69 115 P M5 x 0.8 Rc 1/8 LD 5.6 8.6 Model CYP15 CYP32 Note 1) These dimension drawings indicate the case of piping port position "Nil".
27 WA 32 46 W 69 115 TB 18 22 TA 13 17 T 23 29 R 45 79.5 QW 48 87 N 4.5 7.5 Q 105 138 M 6 8 PB 60 100 MM M4 x 0.7 M6 x 1 PA 25 50 LW 69 115 P M5 x 0.8 Rc 1/8 LD 5.6 8.6 Model CYP15 CYP32 Note 1) These dimension drawings indicate the case of piping port position "Nil".
1 5 7 (40) 4.02 l102) 3.07 (78) 0.98 (25) 205 (52) 0 5 5 (14) 0 8 3 (21) Ml2x1.75 ( 1 1 ) \'17) lV22x1.5 (37) 4 5 7 ( 1 1 6 ) 2 7 9 (71) a m (204) 256 (65) 049 (r2 5) 3 1 5 (80) 8 3 9 1213) E 1 5 7 (40) l r 1 6 ) 3 6 2 (92) (30) 205 (52) 0 5 5 (14) 0 8 3 (21J Ml2x1.75 ( 1 1 ) o 6 7 <17) lV26x1.5 '| 57 (40) 4 9 6 (126) 243 \721 (21s) 2 5 6 (6s) 0 5 5 3 1 9 (81) L A 2 t.2241 "Min Stroke = 0
1in = 25.4mm Scale: 50% MRHQ20 A B 48 59 78 38.5 4-M6 x 1 Depth 10 0 0.074 54h9 26.3 opened + 2.2 0.2 8 0 0.1 M5 x 0.8 0 0.05 10 16.3 closed 0 0.7 4-M4 x 0.7 Finger closing port (mounting screw attachment ) 5 24.5 9 Max. 9.2 51 4-M6x1 Depth 9 (two on opposite side) M5 x 0.8 Finger opening port 3-R2.5 24 3.4 62 16.5 27 19 26 9 39 36 6.5 2-6.5 through 2-11 depth of counter bore 2.8 8 46
(Unit: N) Cylinder bore size (mm) Rod size (mm) Piston area (mm) Operating direction Operating pressure (MPa) 0.2 0.3 0.4 0.5 0.6 0.7 11 17 23 29 34 40 OUT 57 6 3 8 13 17 21 25 29 42 OUT IN 20 30 40 51 61 71 101 8 4 15 23 30 38 45 53 75 OUT IN 45 68 90 113 136 158 226 12 6 34 51 68 85 102 119 IN 170 80 121 161 201 241 281 OUT 402 16 8 60 91 121 151 181 211 IN 302 OUT 628 126 188 251 314 377