When the product is mounted using the bracket, fix with M5 screws (2 pcs.) or equivalent. The Bracket thickness is approx. 1.6 mm.
NN NN MM MM KK LL KK LL 2 x PA (Port for operating cylinder) J I J 2 x PA (Port for operating cylinder) F F F 76.5 91 110 H 73 88 106 J 40 46.5 55 K 46 58 68 M 13 15 19 N 16 15 19 O 18.5 19.5 21.5 F 93.5 107.5 130.5 H 73 88 106 I 76.5 91 110 J 40 46.5 55 K 46 58 68 M 30.9 32.4 41.5 N 16 15 19 Applicable cylinder ML2B25 ML2B32 ML2B40 Applicable cylinder ML2B25 ML2B32 ML2B40 KK 15 16 17.5
ports S.S. (430F) 28 M5 ports brass 29 M5 ports S.S.(303) EXAMPLE G 120 60 58 3 AF 16 P Lead Wire 120 Volt Line A.C. 60 Hertz 3-Way Normally Closed .6MM Inlet Manifold Mount with Manulal Overide 10-32 Sleeve Adapter Series 58 Valve .8MM Exhaust Orifice NOTE: L Marked Prior to numbers denots Low Watt * For 3 way valves, this digit will consist of two suffix letters.
ports S.S. (430F) 28 M5 ports brass 29 M5 ports S.S.(303) EXAMPLE G 120 60 58 3 AF 16 P Lead Wire 120 Volt Line A.C. 60 Hertz 3-Way Normally Closed .6MM Inlet Manifold Mount with Manulal Overide 10-32 Sleeve Adapter Series 58 Valve .8MM Exhaust Orifice NOTE: L Marked Prior to numbers denots Low Watt * For 3 way valves, this digit will consist of two suffix letters.
. * If the step motor and servo motors do not meet your specifications, also consider the AC servo specification (Page 46). 38 Model Selection LEF Series Step Motor (Servo/24 VDC) Servo Motor (24 VDC) Clean Room Specication For the LECPA, refer to page 40.
Step 3) Screw in the accessory unlocking bolt (hexagon socket headcap screw 32: M3 x 8l, 40: M4 x 8l, 50: M4 x 8l, 63: M5 x 10l). 1. Piping port position, switch rail position, and by-pass piping position can be selected by the part number. However, if there is an error in ordering and changes to the positions are required, please note the following. a.
R1/8, M5 x 0.8 NPT1/8, M5 x 0.8 Rc 1/8 Symbol NPT 1/8 4 One-touch fitting R1/8, M5 x 0.8 2 1 6 One-touch fitting 5/32" One-touch fitting NPT1/8, M5 x 0.8 1/4" One-touch fitting M5 x 0.8 female thread is cut inside the pipe.
L4 Note) Weight (g) 5 5.5 6.5 8.5 9.5 19 22 35 38 52 86 95 Model Applicable tubing O.D. d AS1002F-01 AS1002F-03 AS1002F-07 AS2002F-03 AS2002F-07 AS2052F-07 AS2052F-09 AS3002F-07 AS3002F-09 AS3002F-11 AS4002F-11 AS4002F-13 MIN.
PV SV 5.23 Communication Function HRSH Series 5-84 HRX-OM-Q026 Chapter 5 Display and Setting of Various Functions 46. Select a function with [] key or [] key, and press [SEL] to enter.
30 0.115 0.099 0.296 37.5 5 0.115 0.099 0.296 37.5 10 0.153 0.132 0.380 46 15 MXU16 12 0.153 0.132 0.380 46 20 0.190 0.165 0.464 50 25 0.190 0.165 0.464 52.5 30 4.
(Refer to the figure below.) 0.061 0.053 0.062 34 20 0.076 0.066 0.074 38.5 25 0.076 0.066 0.074 41 30 0.047 0.041 0.109 28.5 5 0.047 0.041 0.109 31 10 0.080 0.069 0.169 36 15 MXU10 9.5 0.080 0.069 0.169 38.5 20 0.103 0.089 0.212 44 25 0.103 0.089 0.212 46 30 0.115 0.099 0.296 37.5 5 0.115 0.099 0.296 37.5 10 0.153 0.132 0.380 46 15 MXU16 12 0.153 0.132 0.380 46 20 0.190 0.165 0.464 50 25
M50.8 NIL Without PD port (PV = PD) M5 M50.8 PVPD Note 2)Refer to model indication for single unit (4) for the combinations of supply valve and release valve selectable. 14 - Doc. no.
x 0.8 Hexagon socket head cap plug 2 x 2 x 4.3 through (5H7 hole pitch) 2 x 5H7 depth 6 +0.012 0 4 x M5 x 0.8 thread depth 10 2 x M5 x 0.8 Cylinder port 2 x M8 x 1.0 Adjusting bolt 3 x M5 x 0.8 thread depth 10 4 x 4.2 through Shock absorber Max.
x 0.8 Hexagon socket head cap plug 2 x 2 x 4.3 through (5H7 hole pitch) 2 x 5H7 depth 6 +0.012 0 4 x M5 x 0.8 thread depth 10 2 x M5 x 0.8 Cylinder port 2 x M8 x 1.0 Adjusting bolt 3 x M5 x 0.8 thread depth 10 4 x 4.2 through Shock absorber Max.
27.6 0.05 35 18.6 (34.6) 2 x M5 x 0.8 thread depth 8 (Mounting thread) 4 x M5 x 0.8 thread depth 10 (Mounting thread) Prepared hole dia. 4.3 through (Mounting hole) +0.030 0 depth 4 4H9 7.5 0.02 8 0 0.1 (58) 30 42 32 MHZ 16.8 0.02 MHF MHL 29 +0.052 0 depth 3 21H9 When closed 16.3 0 0.7 When open 26.3 +2.2 0.2 18 20 43.5 MHR 84.8 MHK 2 x M5 x 0.8 thread depth 10 (Mounting thread) MHS M5 x
(A, B port) C4: One-touch fitting for 4 M5: M5 thread 2(B) 2(B) 27.5 20 15 4(A) 4(A) 5 46 12.5 P=11 L plug connector (L) Dimensions n: Stations L n 20 237 229 19 226 218 17 204 196 15 182 174 13 160 152 11 138 130 9 116 108 7 94 86 6 83 75 18 215 207 5 72 64 16 193 185 4 61 53 14 171 163 3 50 42 12 149 141 L2 L1 2 39 31 10 127 119 8 105 97 637
C3: One-touch fitting ass'y for 3 2n-C3, C4, C6, M5 VQZ C3: One-touch fitting ass'y for 3 C4: One-touch fitting ass'y for 4 C4: One-touch fitting ass'y for 4 C6: One-touch fitting ass'y for 6 M5: M5 thread C6: One-touch fitting ass'y for 6 M5: M5 thread VQD 45.5 2.5 10.5 (5) 21.5 VZS Dimensions Equation L1=11n+20 n: Staion ( Max. 24 stations) 7.5 L n 1 31 50 60.5 2 42 62.5 73 3 53 75 85.5
HRX-OM-S004 Contents 8.4.1 HRS100-A-20/40/46. 8-12 8.4.2 HRS150-A-20/40/46. 8-12 8.4.3 HRS100-W-20/40/46. 8-13 8.4.4 HRS150-W-20/40/46. 8-13 8.5 Pump capacity . 8-14 8.5.1 HRS100/150-A/W-20/40/46. 8-14 8.6 Types of Hazard Labels (HRS--40/46-) . 8-15 8.6.1 Positions of danger warning label . 8-16 8.7 Standards . 8-17 8.8 Sample DoC. . 8-18 8.9 Daily Check Sheet . 8-19 Chapter 9 Product Warranty
KAU23-M5 38 9.6 15.5 34.5 9 M5 X 0.8 M6 X 1.0 2.2 2.2 10 38.5 3.4 2.9 11 3.2 9.6 1 8 KAU23-M6 KAU23-U01 11 39.5 KAU04-M5 4 M5 X 0.8 M6 X 1.0 2.2 2.2 KAU04-M6 10 11 16 10.4 36 10.4 40 4 1 8 KAU04-U01 4.2 4.2 11 1 4 KAU04-U02 42 16 14 42.5 KAU06-M5 M5 X 0.8 M6 X 1.0 39 2.2 2.2 12 KAU06-M6 43 13