SMC Corporation of America
Elite Part Number Search
Search Results "SS3YJ3-42-18-N3T"

(For type 20, 41, 42 and 45) Pilot pressure range SS5YA Fill the same as SS5Y . 3 5 7 3 5 7 Pilot pressure MPa Specify the part numbers for valves and options together beneath the manifold base part number. (Example) SS5YA5-42-03-02 1 set (Type 42, 3 station manifold base part no.) SYA5140 1 set (Single air operated valve part no.) SYA5240 1 set (Double air operated valve part no.)

Connector pin numbers 2 1 (43.5) 4 3 A B Pin no. 1 2 3 4 Output specification Pin description DC(+) NC/Analog output DC() OUT A Pulse output only 42 62 52 Pulse output + Analog output 72 Flow direction 18 Series PF2W Dimensions: Remote Type Sensor Unit for Water PF2W511-(N)B 148 80 32 70 58 46 45 2-Port size 2 45 4-5.5 36 (43.5) A A B Output specification 63 Pulse output only 77 73 87 Pulse

Connector pin numbers 2 1 (43.5) 4 3 A B Pin no. 1 2 3 4 Output specification Pin description DC(+) NC/Analog output DC() OUT A Pulse output only 42 62 52 Pulse output + Analog output 72 Flow direction 18 Series PF2W Dimensions: Remote Type Sensor Unit for Water PF2W511-(N)B 148 80 32 70 58 46 45 2-Port size 2 45 4-5.5 36 (43.5) A A B Output specification 63 Pulse output only 77 73 87 Pulse

11-MXJ4 11-MXJ6 11-MXJ8 2 13 8 18 18 4.5 4.5 7 13 8 18 18 22 4.5 4.5 3.5 2.5 14 13 8 9 18 18 29 29 3.5 3.5 4.5 4.5 Auto Switch Mounting When using the solid state auto switch (D-M9), mount it in the illustrated direction.

Set the signal which is suitable for the external switch prepared by the customer. 2.5 Contact input signal HRS090 Series 2-18 HRX-OM-T004 Chapter 2 Contact input/output communication 2.6 Contact output signal There are three contact output signals.

Set the signal which is suitable for the external switch prepared by the customer. 2.5 Contact input signal HRSH Series 2-18 HRX-OM-R028 Chapter 2 Contact input/output communication 2.6 Contact output signal There are three contact output signals.

A,B),20(A,B),25(A)) (MXQ16(A,B),20(A,B),25(A)) 12 13 A 14 15 16 17 18 19 (MXQ6A,8A,12A, MXQ16(A,B),20(A,B),25(A)) 20 21 22 O 19 / 23 24 25 26 27 28 / 29 30 31 32 33 34 35 36 NBR 37 NBR 38 NBR 39 (MXQ6,8(C),12(C)) / 40 (MXQ6,MXQ8(C),MXQ12(C)) 41 NBR (MXQ6,MXQ8(C),MXQ12(C)) 42 (MXQ6,MXQ8(C),MXQ12(C)) 43 20 Revision history 4-14-1, Sotokanda,

HA H HB NT PP PS N A Z + Stroke W Square nut for body mounting J TW (mm) Model A EA EB H HA HB HC HG HP HT J LL LW M MM N REBHT25 REBHT32 125 28.5 79 63 46 46 61.5 19.5 58.5 35 M6 x 1.0 56 119 M6 x 1.0 10 20.5 30 90 75 52.5 57.5 72.5 25 69.5 43 M8 x 1.25 63.5 130 M8 x 1.25 12 23 132.5 Model NL NT PA PB PP PS S TW W XB Z REBHT25 REBHT32 18 9 65 108 18 51 209 110 136 9.5 250 22.5 12 66 115

Form w 1 Material e Buffer spec. r Buffer stroke t Vacuum inlet Flat Type with Groove A 3 30.5 11 1.2 11 04 6 37 14 14.5 10 47 18 20.5 J K Width across flats E 3 30.5 11 1.8 11 6 37 14 14.5 10 47 18 20.5 06 08 N S U F GN GS HS 7 15 55 36.5 1.2 10 20 62.5 44 06 08 15 55 36.5 1.8 20 62.5 44 04 JB K ZP3 T UM B5 C2 3 31.5 12 11 J K 10 6 38 15 14.5 10 48 19 20.5 JB K 15 56 37.5 10 20 63.5 45 10

16 34 312 MHKL2-25D 25 22 19 41 562 MHKL2-12S 90 12 9 11 9 20 105 Normally open Normally closed MHKL2-16S 16 17 14 14.6 28.6 165 MHKL2-20S 20 32 18 16 34 314 MHKL2-25S 25 53 22 19 41 565 MHKL2-12C 12 11 11 9 20 105 L1 MHKL2-16C 16 22 14 14.6 28.6 166 L2 MHKL2-20C 20 40 18 16 34 314 MHKL2-25C 25 63 22 19 41 565 Note) At the pressure of 0.5 MPa, when gripping point L is 20 mm.

A1 L1 MM RR1 NX NZ Material: Rolled steel +0.084 0 +0.084 0 +0.1 0 +0.1 0 +0.1 0 +0.1 0 +0.12 0 +0.3 +0.1 +0.3 +0.1 +0.3 +0.1 +0.3 +0.1 +0.3 +0.1 +0.3 +0.1 +0.3 +0.1 0.1 0.3 0.1 0.3 0.1 0.3 0.1 0.3 0.1 0.3 0.1 0.3 0.1 0.3 125 140 160 180 200 250 300 Y-12 Bore (mm) 32 25 64 Part No. 8 46 100 M30 X 1.5 27 42 C B H d D Y-14 125/140 160 180 200 250 300 NT-12 NT-16 NT-18 NT-20 NT-25 NT-30 36 28

15.2 18 5/16" AS2051F-09 AS3001F-10 32 35.6 40.6 9.8 71.6 18.5 10 21 42 33.3 38.3 7.4 59 13.2 17 1/4" AS3001F-07 AS3001F-12 33 36.8 41.8 11 76 20.9 12 22 19.8 46 34.1 39.1 8.2 64.4 15.2 18 5/16" AS3001F-09 AS4001F-10 36 43.6 51.1 18.5 10 21 82 11.3 26.5 53 35.3 40.3 9.5 70.8 17.9 21 3/8" AS3001F-11 AS4001F-12 40 44.6 52.1 20.9 12 22 97 43.5 51 10.3 76.9 17.9 21 3/8" AS4001F-11 26.5 106 44.9

16 34 312 MHKL2-25D 25 22 19 41 562 MHKL2-12S 90 12 9 11 9 20 105 Normally open Normally closed MHKL2-16S 16 17 14 14.6 28.6 165 MHKL2-20S 20 32 18 16 34 314 MHKL2-25S 25 53 22 19 41 565 MHKL2-12C 12 11 11 9 20 105 L1 MHKL2-16C 16 22 14 14.6 28.6 166 L2 MHKL2-20C 20 40 18 16 34 314 MHKL2-25C 25 63 22 19 41 565 Note) At the pressure of 0.5 MPa, when gripping point L is 20 mm.

16 34 312 Auto switch MHKL2-25D 25 22 19 41 562 MHKL2-12S 90 105 20 9 11 12 9 Normally open Normally closed MHKL2-16S 165 28.6 14.6 14 16 17 MHKL2-20S 314 34 16 18 20 32 MHKL2-25S 565 41 19 22 25 53 L1 Single acting MHKL2-12C 105 20 9 11 12 11 L2 MHKL2-16C 166 28.6 14.6 14 16 22 MHKL2-20C 314 34 16 18 20 40 MHKL2-25C 565 41 19 22 25 63 Note) At the pressure of 0.5MPa , when holding point

DMA-625 5 18-18 DMA-750 34-16 DMA-875 78-14 DMA-1000 1-14 DMA-1250 114-12 www.poweraire.com 1-800-526-7661 18 Section II: Cylinders High Temperature Operations Q: I have an application in a high temperature environment. What should I do to avoid complication? A: The control valve powering the cylinder should be mounted as far away from the heat as possible.

DMA-625 5 18-18 DMA-750 34-16 DMA-875 78-14 DMA-1000 1-14 DMA-1250 114-12 www.poweraire.com 1-800-526-7661 18 Section II: Cylinders High Temperature Operations Q: I have an application in a high temperature environment. What should I do to avoid complication? A: The control valve powering the cylinder should be mounted as far away from the heat as possible.

L* N x 4 N x 8 N x 12 N x 6 N x 12 N x 18 N x 8 N x 16 N x 10 N x 20 N x 12 N x 24 D 18 28 28 24 37 37 31 42 52 52 67 67 TCU0425-1N-X6 TCU0425-2N-X6 TCU0425-3-N-X6 TCU0604-1-N-X6 TCU0604-2-N-X6 TCU0604-3-N-X6 TCU0805-1-N-X6 TCU0805-2-N-X6 TCU1065-1-N-X6 TCU1065-2-N-X6 TCU1208 -1-N-X6 TCU1208 -2-N-X6 LX5.9 + 200 LX4.4 + 200 LX2.9 + 200 LX5.3 + 200 LX3.8 + 200 LX2.5 + 200 LX5.2 + 200 LX3 +

G Description 04 06 10 02 03 04 02 03 04 VY110 0 1VY120 0 1VY130 0 1VY140 0 1VY170 0 11 1 0 2 VY190 0 11 2 4 0 VY1D00-M5 VY1A0 0 1-M5 VY150 0 1VY1B0 0 1M 0 5 1 01 02 01 02 PPA B VEX9-32A VEX5-32A VEX7-32A VEX3-32A VEXA-18-2A VEX1-18-1A Bracket (With bolt, washer) AL F VEX1-18-2A VEXA-18-3A G27-10-R1-X207 G G46-10-01 G36-10-01 G27-10-01 Pressure gauge AN120-M5 AN120-M5 Pilot EXH port silencer

Refer to page 829-10. 8-29-17 18 Dual Rod Cylinder: With End Lock For Retraction Side Series CXS 6, 10, 15, 20, 25, 32 How to Order CXS M Y7BW 50 S R 10 Number of auto switches Nil S n 2 pcs. 1 pc. n pcs.

/Current) Enclosure IP40 IP40 Piping M5 female thread, R1/8, NPT1/8 Note Copy function, Auto-shift function CONTENTS 3-Screen Display High-Precision Digital Pressure Switch ZSE20(F)/ISE20 Series How to Order p. 9 Specifications p. 10 Set Pressure Range and Rated Pressure Range p. 17 Analog Output p. 17 IO-Link: Process Data p. 17 Functions p. 17 Internal Circuits and Wiring Examples p. 18