, 8, 10 4 6 8, 10 6 8 10, 12 10 12 Tubing O.D. 1/8", 5/32" 3/16", 1/4" 1/8" 5/32" 3/16", 1/4" 5/16" 1/4", 5/16" 3/8" 1/4" Inch size 5/32" 3/16" 5/16" 3/8" 3/8" 1/2" Flow rate (l/min (ANR)) 100 180 230 260 390 460 660 790 920 1580 1710 Controlled flow (Free flow) 1.5 2.7 3.5 4 6 7 10 12 14 24 26 Effective area (mm2) Note) Flow rate values are at a pressure of 0.5 MPa and a temperature of 20C

Magnetic field resistance 14.5 mT Power supply 10.8 to 26.4 DC (Power supply ripple: 1% or less) Current consumption 40 mA Foot Note 1) Flange Bore size (mm) Double clevis Resolution 0.1 mm/pulse 0.2 mm (at 20C) (1) Accuracy 12 20 32 40 50 63 CQ-L012 CQ-F012 CQ-D012 Output type Open collector (24 VDC, 40 mA) CQ-L020 CQ-F020 CQ-D020 Output signal A/B phase difference output CQ-L032 CQ-F032

(Coil temperature: 20C, at rated voltage, without surge suppressor) Note 2) Impact resistance: No malfunction occurred when it is tested with a drop tester in the axial direction and at the right angles to the main valve and armature in both energized and de-energized states every once for each condition.

. * Cannot be used for movable wiring Electrical Characteristics Connector manufacturers example Item Property Conductor resistance W/km, 20C 65 or less Fujitsu Limited Japan Aviation Electronics Industry, Ltd. J.S.T. Mfg. Co., Ltd. HIROSE ELECTRIC CO., LTD.

De-energized, Initial value) ZL1 Series ZL3/ZL6 Series With vacuum pressure detection port Supply Valve/Release Valve Specifications Model SYJ5m4 Port exhaust Response time (at 0.5 MPa)*1 25 ms or less Max. operating frequency 5 Hz Manual override Non-locking push type, Push-turn locking slotted type *1 Based on JIS B 8419: 2010 dynamic performance test (Standard type: Coil temperature 20C

FR one-touch fittings: Series KR-W2 Metal one-touch fittings: Series KQB2 Applicable fittings At 20C 0.8 MPa Max. operating pressure At 40C 0.65 MPa How to measure the minimum bending radius At 60C 0.5 MPa Burst pressure Refer to the burst pressure characteristics curve.

Refrigerant HFC134a JIS Symbol Auto drain AD38 AD37 AD48 Port size 3/8 1/2 3/4 (kg) Weight 16 18 23 28 17 22 27 Refrigerated air dryer Body panel: White 1 (Munsell 10Y8/0.5) Base: Gray 2 (Munsell 10Y5/0.5) Coating color Auto drain Applicable air compressor output (Guide) In the case of a screw type (kW) 0.75 1.5 2.2 3.7 5.5 7.5 11 Note 1) The data for l/min (ANR) is under the conditions of 20C

.: 4, 6, 8, 10, 12, Applicable fittings include: KQ, KJ, KF, KFG, and M/MS, Tubing colors include: black, white, red, blue, yellow green, Maximum operating pressure: 20C = 0.8 MPa and 60C = 0.4 MPa, TUBING, WEAR RESISTANT, CONNECTORS, TUZ WEAR RESISTANT TUBING, FX, TUZ 6MM, .86112 lb, ModelTubing O.D. (mm)Tubing I.D. (mm)--TUZ060464--

Standard condition (ANR) and normal condition (NOR) are defined as follows: Standard condition (ANR): 101.3kPa, 20C, 65%RH. Normal condition (NOR): 101.3kPa, 0C Press the or button in function selection mode to display [F 4]. Press the button.

Standard condition and normal condition are defined as follows: Standard condition: Displayed flow rate which is converted to volume at 20C, 101.3 kPa (absolute pressure). Normal condition: Displayed flow rate which is converted to volume at 0C, 101.3 kPa (absolute pressure).

Standard condition and normal condition are defined as follows: Standard condition: Displayed flow rate which is converted to volume at 20C, 101.3 kPa (absolute pressure). Normal condition: Displayed flow rate which is converted to volume at 0C, 101.3 kPa (absolute pressure).

Standard condition and normal condition are defined as follows: Standard condition: Displayed flow rate which is converted to volume at 20C, 101.3 kPa (absolute pressure). Normal condition: Displayed flow rate which is converted to volume at 0C, 101.3 kPa (absolute pressure).

Standard condition and normal condition are defined as follows: Standard condition: Displayed flow rate which is converted to volume at 20C, 101.3 kPa (absolute pressure). Normal condition: Displayed flow rate which is converted to volume at 0C, 101.3 kPa (absolute pressure).

SUS316L Stainless Steel Fitting Specifications Applicable tubing Nylon/Fluoro tubing Fluid Water/Chemical base paint, Ink, Cleaning solvent (Water, Butyl acetate), Air Max. operating pressure (at 20C) (MPa) 1.0 (C) Ambient and fluid temperature 0 to 60 Weight VCC12 (2 port) 37 g Valve VCC13 (3 port) 48 g For 2 port 29 g Blanking plug assembly For 3 port 45 g For 2 port (2 stations, one-piece

W (due to an increase in the heat generation of the pump) Note 1) -MT: Applicable to deionized water piping + High pressure pump Note 2) The capacity at the thermo-chiller outlet when the circulating fluid temperature is 20C. Note 3) Required minimum flow rate for cooling capacity or maintaining the temperature stability. Note 4) Cooling capacity will decrease as pump power increases.

W (due to an increase in the heat generation of the pump) Note 1) -MT: Applicable to deionized water piping + High pressure pump Note 2) The capacity at the thermo-chiller outlet when the circulating fluid temperature is 20C. Note 3) Required minimum flow rate for cooling capacity or maintaining the temperature stability. Note 4) Cooling capacity will decrease as pump power increases.

Installation environment and power supply are within specification range and stable. 6 The capacity at the thermo-chiller outlet when the circulating fluid temp. is 20C. 7 Fluid flow to maintain the cooling capacity and the temperature stability.

Installation environment and power supply are within specification range and stable. 6 The capacity at the thermo-chiller outlet when the circulating fluid temp. is 20C. 7 Fluid flow to maintain the cooling capacity and the temperature stability.

Heater operation, PID control Refrigerant type/Refrigerant charge R134a/0.14kg R134a/0.26kg Niose level (reference value) Note 7) 52dB (A) 55dB (A) Weight 26kg 37kg Applicable drain tube O.D. 10mm Coating colour Body panels:White 1 Base:Gray 2 IP Class IP2X Overvoltage Category Category / IEC60664-1 Pollution Degree Degree 2 Applicable directive CE Marking Note 1: ANR refers to conditions of 20C

the slave at the trunk end is connected in T branch, it is necessary to connect terminal resistance by the cable longer than length of stay branched from trunk so that the terminal resistance would be positioned the most far from master. 6-3 Cable for communication line Type Specification Vinyl code VCTF JIS C3306 2 cores, Nominal section 0.75mm2 (Signal line 2) Conductor resistance(at 20C