Series: 25A-PF3W5, Rated Flow Range: 04 (0.5 to 4 L/min), Flow Adjustment: S (w/Flow Adjustment Valve), Thread: N (NPT), Port Size: 03 (3/8), Output Specification/Temperature Sensor: 1 (Out 1 Flow Rate: Analog 1 to 5 V; Out 2 Temperature: None; Temperature Sensor: None), Lead Wire: w/Lead Wire and M8 Connector, 3 m, Unit Specification: G [Instantaneous Flow: L/min (gal/min); Temperature:
Rated Flow Range: 20 (2 to 16 L/min), Flow Adjustment Valve: None, Thread: N (NPT), Port Size: 03 (3/8), Output Specification: B (OUT1: PNP; OUT2: PNP), Temperature Sensor: T (Temperature Sensor), Lead Wire: N (w/o Lead Wire w/M8 Connector), Unit Specification: G (Instantaneous Flow Rate: Gal/min; Accumulated Flow: Gal; Temp: °C), Bracket: R (Bracket), Calibration Certificate: None, Made
Rated Flow Range: 20 (2 to 16 L/min), Flow Adjustment Valve: None, Thread: N (NPT), Port Size: 03 (3/8), Output Specification: E (OUT1: PNP; OUT2: Analog 1 to 5V), Temperature Sensor: T (Temperature Sensor), Lead Wire: Lead Wire w/M8 Connector, 3m, Unit Specification: G (Instantaneous Flow Rate: Gal/min; Accumulated Flow: Gal; Temp: °C), Bracket: R (Bracket), Calibration Certificate: None
Rated Flow Range: 20 (2 to 16 L/min), Flow Adjustment Valve: None, Thread: N (NPT), Port Size: 03 (3/8), Output Specification: E (OUT1: PNP; OUT2: Analog 1 to 5V), Temperature Sensor: T (Temperature Sensor), Lead Wire: Lead Wire w/M8 Connector, 3m, Unit Specification: G (Instantaneous Flow Rate: Gal/min; Accumulated Flow: Gal; Temp: °C), Bracket: R (Bracket), Calibration Certificate: None
Rated Flow Range: 04 (0.5 to 4L/min), Flow Adjustment Valve: S (Flow Adjustment Valve), Thread: N (NPT), Port Size: 03 (3/8), Output Specification: 2 (OUT1: Analog 4 to 20mA), Temperature Sensor: T (OUT2: Analog 1 to 5V, w/Temperature Sensor), Lead Wire: Lead Wire w/M8 Connector, 3m, Units on Label: G (Instantaneous Flow Rate: Gal/min; Accumulated Flow: Gal; Temp: °C), Bracket: R (Bracket
Series: 25A-PF3W5, Rated Flow Range: 0.5 to 4 L/min, Flow Adjustment: w/Flow Adjustment Valve, Thread: NPT, Port Size: 3/8, Output Specification/Temperature Sensor: Out 1 Flow Rate: Analog 1 to 5 V; Out 2 Temperature: None; Temperature Sensor: None, Lead Wire: w/Lead Wire and M8 Connector, 3 m, Unit Specification: G [Instantaneous Flow: L/min (gal/min); Temperature: °C/°F], Bracket: w/Bracket
Rated Flow Range: 0.5 to 4L/min, Flow Adjustment Valve: Flow Adjustment Valve, Thread: NPT, Port Size: 3/8, Output Specification: OUT1: Analog 4 to 20mA, Temperature Sensor: OUT2: Analog 1 to 5V, w/Temperature Sensor, Lead Wire: Lead Wire w/M8 Connector, 3m, Units on Label: Instantaneous Flow Rate: Gal/min; Accumulated Flow: Gal; Temp: °C, Bracket: Bracket, Calibration Certificate: None,
Rated Flow Range: 2 to 16 L/min, Flow Adjustment Valve: None, Thread: NPT, Port Size: 3/8, Output Specification: OUT1: PNP; OUT2: PNP, Temperature Sensor: Temperature Sensor, Lead Wire: w/o Lead Wire w/M8 Connector, Unit Specification: Instantaneous Flow Rate: Gal/min; Accumulated Flow: Gal; Temp: °C, Bracket: Bracket, Calibration Certificate: None, Made to Order: Piping Material Brass
Rated Flow Range: 2 to 16 L/min, Flow Adjustment Valve: None, Thread: NPT, Port Size: 3/8, Output Specification: OUT1: PNP; OUT2: Analog 1 to 5V, Temperature Sensor: Temperature Sensor, Lead Wire: Lead Wire w/M8 Connector, 3m, Unit Specification: Instantaneous Flow Rate: Gal/min; Accumulated Flow: Gal; Temp: °C, Bracket: Bracket, Calibration Certificate: None, Made to Order: EPDM Seal Material
Rated Flow Range: 2 to 16 L/min, Flow Adjustment Valve: None, Thread: NPT, Port Size: 3/8, Output Specification: OUT1: PNP; OUT2: Analog 1 to 5V, Temperature Sensor: Temperature Sensor, Lead Wire: Lead Wire w/M8 Connector, 3m, Unit Specification: Instantaneous Flow Rate: Gal/min; Accumulated Flow: Gal; Temp: °C, Bracket: Bracket, Calibration Certificate: None, Made to Order: Piping Material
Flow Switch Type: 5 (Remote Sensor Unit), Rated Flow Range: 04 (0.5~4L/min), Return Unit: None, Thread: N (NPT), Port Size: 03 (3/8), Flow Switch Output: 1T (Remote Sensor Unit; Out 1: Analog 1 to 5 V; Out 2: Flow Rate: None, Temp. Analog 1 to 5 V; Temperature Sensor: Yes)
Series PF3W digital flow switch is perfect for applications requiring a constantly monitored flow of cooling or cleaning water. The PF3W series has been improved both in design and operating performance over the PF2W flow switch. Depending on the selected model, the PF3W is up to 40% smaller in volume, offering improved piping space and flexibility. Designed to work with fluids up to 90ºC
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, IFW/PFW 3/8INCH NPT VERSION, INSTRUMENTATION, IFW/PFW FLOW SWITCH, EB, IFW/PFW 3/8INCH NPT VERSION, 0.4299 lb
Valve; w/Stop Valve), Supply/Return Port Size: 03 (3/8), Return Unit Flow Switch Output Specifications: 1T (Out 1: Analog 1 to 5 V; Out 2: Flow Rate: None; Temp.: Analog 1 to 5 V; Temperature Sensor: Yes)
Valve; w/Stop Valve), Supply/Return Port Size: 03 (3/8), Return Unit Flow Switch Output Specifications: 1T (Out 1: Analog 1 to 5 V; Out 2: Flow Rate: None; Temp.: Analog 1 to 5 V; Temperature Sensor: Yes)
Valve: None; Stop Valve: None, Supply/Return Port Size: 04 (1/2), Return Unit Flow Switch Output Specifications: 1T (Out 1: Analog 1 to 5 V; Out 2: Flow Rate: None; Temp.: Analog 1 to 5 V; Temperature Sensor: Yes)
MSU OTHER SIZE RATING. .41424 lb. 1T.