Lock: L (w/Lock), Mounting Surface: A (Same Side as Port), Guide Pin Diameter: 125 (12.5mm), Guide Pin Shape: R (Round Type), Clamp Arm Position: A (Same Side as Port), Clamping Height: L (Low Type), Auto Switch: W/out Auto Switch (Built-in Magnet), Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs.
Lock: W/out Lock, Mounting Surface: C (180° from Port Side), Guide Pin Diameter: 125 (12.5mm), Guide Pin Shape: R (Round Type), Clamp Arm Position: A (Same Side as Port), Clamping Height: L (Low Type), Auto Switch: M9P--Solid State, Gen. Purpose, 3 Wire PNP, Horizontal, Lead Wire or Prewired Connector: SAPC (0.5m Cord Length, M8-3 Pin Connector), Number: 2 pcs.
Lock: W/out Lock, Mounting Surface: C (180° from Port Side), Guide Pin Diameter: 125 (12.5mm), Guide Pin Shape: R (Round Type), Clamp Arm Position: A (Same Side as Port), Clamping Height: L (Low Type), Auto Switch: W/out Auto Switch (Built-in Magnet), Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs.
Main Body Peripheral Component: Main Body, Type: Sliders, Stroke(mm): 125, Max. Transportable Mass Range (Horizontal)(kg): 2.1 to 5.0, Max. Transportable Mass (Horizontal)(kg): 5, Max. Transportable Mass Range (Vertical)(kg): 0 to 2.0, Max.
Main Body Peripheral Component: Main Body, Type: Sliders, Stroke(mm): 125, Max. Transportable Mass Range (Horizontal)(kg): 2.1 to 5.0, Max. Transportable Mass (Horizontal)(kg): 5, Max. Transportable Mass Range (Vertical)(kg): 0 to 2.0, Max.
Main Body Peripheral Component: Main Body, Type: Sliders, Stroke(mm): 125, Max. Transportable Mass Range (Horizontal)(kg): 2.1 to 5.0, Max. Transportable Mass (Horizontal)(kg): 5, Max. Transportable Mass Range (Vertical)(kg): 2.1 to 5.0, Max.
Main Body Peripheral Component: Main Body, Type: Sliders, Stroke(mm): 125, Max. Transportable Mass Range (Horizontal)(kg): 2.1 to 5.0, Max. Transportable Mass (Horizontal)(kg): 5, Max. Transportable Mass Range (Vertical)(kg): 2.1 to 5.0, Max.
Main Body Peripheral Component: Main Body, Type: Sliders, Stroke(mm): 125, Max. Transportable Mass Range (Horizontal)(kg): 2.1 to 5.0, Max. Transportable Mass (Horizontal)(kg): 5, Max. Transportable Mass Range (Vertical)(kg): 2.1 to 5.0, Max.
, and center trunnion , With or without rod boot , Variety of switches and a variety of lead wire lengths, SLIDE BEARING R (MY1B50/63), ACTUATOR, 50MM MY1B PARTS, .00308 lb
. *** These units are not available for use in the United States or Canada *** 50/60 Hz operation ; Max. inlet air temperature: 140°F (60°C) ; Max. flow at rated conditions: 1,059 scfm (30m³/min (ANR) @50°F (10°C) PDP; Connections: R threads are standard on size 100, JIS flange on sizes 125/150
. *** These units are not available for use in the United States or Canada *** 50/60 Hz operation; Max. inlet air temperature: 140°F (60°C); Max. flow at rated conditions: 1,059 scfm 30m³/min (ANR) @50°F (10°C) PDP; Connections: R threads are standard on size 100, JIS flanges on sizes 125/150
. *** These units are not available for use in the United States or Canada *** EC Directive compliant with CE marking for use in Europe, Asia, and Oceania; 50 Hz operation; Max. inlet air temperature: 140°F (60°C); Max. flow at rated conditions: 788 scfm 1,340 m³/hr [ANR])@37°F (3°C) PDP; Connections: R threads are standard on sizes 100/125, DIN flange on size 150
. *** These units are not available for use in the United States or Canada *** 50/60 Hz operation ; Max. inlet air temperature: 140°F (60°C) ; Max. flow at rated conditions: 1,059 scfm (30m³/min (ANR) @50°F (10°C) PDP; Connections: R threads are standard on size 100, JIS flange on sizes 125/150
. *** These units are not available for use in the United States or Canada *** EC Directive compliant with CE marking for use in Europe, Asia, and Oceania; 50 Hz operation; Max. inlet air temperature: 140°F (60°C); Max. flow at rated conditions: 788 scfm 1,340 m³/hr [ANR])@37°F (3°C) PDP; Connections: R threads are standard on sizes 100/125, DIN flange on size 150
. *** These units are not available for use in the United States or Canada *** 50/60 Hz operation; Max. inlet air temperature: 140°F (60°C); Max. flow at rated conditions: 1,059 scfm 30m³/min (ANR) @50°F (10°C) PDP; Connections: R threads are standard on size 100, JIS flanges on sizes 125/150
Body material: 316SS ; Max operating pressure psig (MPa): 125 (0.9) ; Connections: compression, Rc, R, NPT ; Normally closed
Lock: L (With Lock), Guide Pin Diameter: 125 (12.5mm), Guide Pin Shape: R (Round Type), Clamp Arm Position: A (Same Direction as Port Side), Clamping Height: L (Low Type), Auto Switch: P3DWASC--Solid State, 2-color Indication, Magnetic Field Resis., 2 Wire, Number: 2 pcs. (or None in the Case of No Switch), Made to Order: X2321
Lock: L (With Lock), Guide Pin Diameter: 125 (12.5mm), Guide Pin Shape: R (Round Type), Clamp Arm Position: A (Same Direction as Port Side), Clamping Height: L (Low Type), Auto Switch: P3DWAZ--Solid State, 2-color Indication, Magnetic Field Resis., 2 Wire, Number: 2 pcs. (or None in the Case of No Switch), Made to Order: X2321
Lock: Without Lock, Guide Pin Diameter: 125 (12.5mm), Guide Pin Shape: R (Round Type), Clamp Arm Position: B (Opposite Direction of Port Side), Clamping Height: L (Low Type), Auto Switch: P3DWASE--Solid State, 2-color Indication, Magnetic Field Resis., 2 Wire, Number: 2 pcs. (or None in the Case of No Switch), Made to Order: X2321
. + N.C.), Applicable Cylinder Diameter(Ø): 125 or less, Pipe Port Type: [Rc (R)] Rc, Port Size: 1/8, Connecting Tube Diameter: -, Pressure Rating(MPa): 0.15~0.7, Driving Type: Pilot Type Spool, Pilot Air Supply: Internal, Seal Type: Soft Seal, Plumbing: Direct Plumbing, Coil specifications: Standard, Manual: Non-locking, push type, Indicator light / Surge voltage suppressor: With indicator