SMC Corporation of America
Elite Part Number Search
Search Results "LEY16C-150-R1"

Type: Standard, Body Material: 304 Stainless Steel, Compatible Fluid: Water / Air, Thread Type: Threaded Type, Operating Environment Application: Standard, Operating Temperature Range(°C): -5~150, Operating Pressure Range(MPa): -0.1~1, Size of Body: 1/8, Pipe Connection Bore Dia.: R1/4, With or Without Check Valve: N

Type: Standard, Body Material: 304 Stainless Steel, Compatible Fluid: Water / Air, Thread Type: Threaded Type, Operating Environment Application: Standard, Operating Temperature Range(°C): -5~150, Operating Pressure Range(MPa): 0~1, Size of Body: 1/4, Pipe Connection Bore Dia.: R1/4, With or Without Check Valve: Y

Type: Standard, Body Material: 304 Stainless Steel, Compatible Fluid: Water / Air, Thread Type: Threaded Type, Operating Environment Application: Standard, Operating Temperature Range(°C): -5~150, Operating Pressure Range(MPa): 0~1, Size of Body: 1/4, Pipe Connection Bore Dia.: R1/4, With or Without Check Valve: N

Type: Standard, Body Material: 304 Stainless Steel, Compatible Fluid: Water / Air, Thread Type: Threaded Type, Operating Environment Application: Standard, Operating Temperature Range(°C): -5~150, Operating Pressure Range(MPa): 0~1, Size of Body: 1/4, Pipe Connection Bore Dia.: R1/2, With or Without Check Valve: Y

Type: Standard, Body Material: 304 Stainless Steel, Compatible Fluid: Water / Air, Thread Type: Threaded Type, Operating Environment Application: Standard, Operating Temperature Range(°C): -5~150, Operating Pressure Range(MPa): 0~1, Size of Body: 1/2, Pipe Connection Bore Dia.: R1/2, With or Without Check Valve: Y

Type: Standard, Body Material: 304 Stainless Steel, Compatible Fluid: Water / Air, Thread Type: Threaded Type, Operating Environment Application: Standard, Operating Temperature Range(°C): -5~150, Operating Pressure Range(MPa): 0~1, Size of Body: 1/2, Pipe Connection Bore Dia.: R1/2, With or Without Check Valve: N

Type: Standard, Body Material: 304 Stainless Steel, Compatible Fluid: Water / Air, Thread Type: Threaded Type, Operating Environment Application: Standard, Operating Temperature Range(°C): -5~150, Operating Pressure Range(MPa): 0~1, Size of Body: 3/4, Pipe Connection Bore Dia.: R1/2, With or Without Check Valve: Y

Type: Standard, Body Material: 304 Stainless Steel, Compatible Fluid: Water / Air, Thread Type: Threaded Type, Operating Environment Application: Standard, Operating Temperature Range(°C): -5~150, Operating Pressure Range(MPa): 0~1, Size of Body: 1, Pipe Connection Bore Dia.: R1, With or Without Check Valve: Y

IN IN Material 30 40 VDW30-CP7 VDW40-CP10 Stainless steel P7 quick fastener P10 quick fastener R1 L2 Ten pieces come in each set. Quick fastener clip OUT OUT 90 right direction Note) Cannot be reassembled in different combinations. IN Male quick fastener R2 ( Male quick fasteners are not included.)

less Power supply voltage effect 0.3% F.S. or less Enclosure IP65 Operating temperature range Operating: 10 to 60C, Stored: 20 to 70C (No condensation or freezing) Operating humidity range Operating/Stored: 35 to 85% RH (No condensation) Resistance Withstand voltage 250 VAC for 1 minute between live parts and case Insulation resistance 50 M between live parts and case (at 50 VDC) 10 to 150

Communication Plug Connector: T-branch, Controller Mounting: Screw, Size: 16, Motor Mounting Position: Top, Lead: Size 16: 2.5mm, Size 25: 3mm, Size 32/40: 4mm, Stroke, mm: 150

Series LECP6 controller has two available modes for the setting software and teaching box.  In the easy mode, the operation can be started by only setting the speed, position, etc.  Using the normal mode allows a further detailed setup.  A few of the main functions of the LECP6 controller are actuator control, specified force operation, separated power supply, and returning the actuator

The rod type electric actuator LEY series has various body sizes with thrust equivalent to 16, 25, and 32 bore size. Direct or bracket mountings are available in three directions or types. Thrust, speed and positioning * can be managed with the use of an optional controller. Possible applications include transfer, opening and shutting, pressing, pushing, and press-fitting.Selectable mounting

The rod type electric actuator LEY series has various body sizes with thrust equivalent to 16, 25, and 32 bore size. Direct or bracket mountings are available in three directions or types. Thrust, speed and positioning * can be managed with the use of an optional controller. Possible applications include transfer, opening and shutting, pressing, pushing, and press-fitting.Selectable mounting

Protocol: EtherNet/IPâ„¢, Mounting: Screw Mounting, Cable Connector: w/o Plug Connector, Actuator: LEY, Type: Rod Type, Body Size: 16, Bearing Type: None, Motor Mounting: Top Mounting Type, Lead: 16: 2.5mm; 25: 3mm; 32, 40: 4mm, Stroke: 150mm

Protocol: CC-Link, Mounting: Screw Mounting, Cable Connector: T-branch Type, Actuator: LEY, Type: Rod Type, Body Size: 16, Bearing Type: None, Motor Mounting: Top Mounting Type, Lead: 16: 2.5mm; 25: 3mm; 32, 40: 4mm, Stroke: 150mm

Size: 16, Motor Mounting Position: Top, Motor: Step Motor (Servo 24 VDC), Lead Screw: C (Size 16: 2.5mm, Size 25: 3mm, Size 32/40: 4mm), Stroke: 150mm, Motor Option: None, Rod End Thread: Female, Mounting: Both Ends Tapped (Standard), Actuator Cable: Without Cable, Actuator Cable Length: Without Cable, Controller Type - LEC, JXC: 6P (LECA6, PNP, Step Data Input Type), I/O Cable Length for

Size: 16, Motor Mounting Position: Top, Motor: Step Motor (Servo 24 VDC), Lead Screw: C (Size 16: 2.5mm, Size 25: 3mm, Size 32/40: 4mm), Stroke: 150mm, Motor Option: None, Rod End Thread: Female, Mounting: Both Ends Tapped (Standard), Actuator Cable: S (Standard Cable), Actuator Cable Length: 1 (1.5m), Controller Type - LEC, JXC: 6P (LECA6, PNP, Step Data Input Type), I/O Cable Length for

Size: 16, Motor Mounting Position: Top, Motor: Step Motor (Servo 24 VDC), Lead Screw: C (Size 16: 2.5mm, Size 25: 3mm, Size 32/40: 4mm), Stroke: 150mm, Motor Option: None, Rod End Thread: Female, Mounting: Both Ends Tapped (Standard), Actuator Cable: S (Standard Cable), Actuator Cable Length: 3 (3m)

Size: 16, Motor Mounting Position: Top, Motor: Step Motor (Servo 24 VDC), Lead Screw: C (Size 16: 2.5mm, Size 25: 3mm, Size 32/40: 4mm), Stroke: 150mm, Motor Option: None, Rod End Thread: Female, Mounting: Both Ends Tapped (Standard), Actuator Cable: S (Standard Cable), Actuator Cable Length: 5 (5m), Controller Type - LEC, JXC: 6P (LECA6, PNP, Step Data Input Type), I/O Cable Length for LEC