Flat finger [3] 4 x MM thread depth L Thread for mounting attachment K J A A D G B D B K J F C S W O (mm) Weight (g) F G Open Closed 2 2.5 3 4 L MM J K D C B Model A W MHZ2-10D3 1), 2) 11221122112211220 -0.05 0 -0.05 0 -0.05 0 -0.05 +0.5 +0.3 +0.5 +0.3 +0.5 +0.3 +0.5 +0.3 +0.025 0 +0.025 0 +0.025 0 +0.030 0 +2.2 0 +2.2 0 +2.3 0 +2.5 0 60 125 250 450 5 6 8 10 M2.5 x 0.45 M3 x 0.5 M4 x 0.7
Locations where the ambient humidity is outside the range of the humidity specification (refer to specifications). d. Locations where corrosive gas, flammable gas, seawater, water and steam are present. e. Locations where strong magnetic or electric fields are generated. f. Locations where direct vibration or impact is applied to the product. g.
For actuators with external stopper, the rotation end can be set within the ranges shown in the drawing by adjusting the stopper bolt. c l o r e c t k n w u o i s C e CRB2 CRBU2 CRB1 MSU B port A port C e l o s c i w k CRJ Basic type For 90 and 100 For 180 and 190 CRA1 Single flat Single flat CRQ2 MSQ MRQ D+10 0 B port A port B port A port +8 0 00 20t 1 0 t 9 fla la gle e f gl sin sin of
Basic type Front ported D-F9 Side ported With external stopper D-M9 11-6-3 4 Series CRJ Precautions Be sure to read before handling.
D 3 Set the test operation select switch to the Up Position, when performing the test operation mode by using set up software (MR ConfiguratorTM) E 2 F 1 0 (Note) This table indicates the status when the switch is set to "Down".
D The air in the cylinder initially opens the piston valve and the check valve and discharges rapidly through the switching valve. The fully opened piston valve closes as shown in Fig. D when the pressure in the cylinder is lower than the set pressure. Then the air passes through the check valve and becomes discharged (Fig. D).
B F Accumulated pulse output Brown 1 Load ON OFF OUT1 Main circuit Main circuit 4 Black Analog output White A 50 msec 2 + 24 VDC Load DOWN MODE SET U P 3 Blue C 2-G 60 Load is an analog input equipment such as a voltmeter, ammeter.
U D E SGC Bracket (Option) A B 15 SGH VNC 1(A) (Back side 2(B)) Main port T C Port size: refer to table below A B VNH VND VND Main port 1(A), 2(B) A B C D E F G M N P Q R S T U Model VCC VND20D-10A VND20D-15A VND30D-20A VND40D-25A 3 8 1 2 3 4 1 63 42 28 14 73.5 81.5 4 52 26 4.5 24.3 2.3 25 34 56 TQ 80 90 50 60 35 44 17.5 22 85 101 93 109 5 6 62 72 31 36 5.5 6.5 28.3 33.3 2.3 2.3 30 35 43
Connector type F: D-sub connector (25 pins) P: Flat ribbon cable (26 pins) SUP/EXH block mounting position Power supply terminals LOCK FREE LOCK FREE U side (2 to 10 stations) U D B M Specifications Symbol P P12 N N12 D side (2 to 10 stations) 24 VDC, Positive common Both sides (2 to 20 stations) 12 VDC, Positive common Special specifications 24 VDC, Negative common For special specifications
bracket) are included with the above parts. 3 Series VCB Direct Operated 2 Port for Heated Water Dimensions (mm) 1in = 25.4mm Grommet: G Conduit: C Q Approx. 300 F D Approx. 280 D Q F C G1/2 C R R E E B A H 2-P Port size 2-P A 2-M Thread depth N B H Port size 2-M Thread depth N L L K K Conduit terminal: T F (Q) 34 25 U R C G1/2 E B A H D 2-P Port size (S) 2-M Thread depth N L K (mm) Electrical
(ON when there is no problem) B5 White A5 Purple Error signal OUT (B contact) Wiring Circuit Shield IZF21/31 IZF21/31 Shield Green F . G. Ground the F.G. cable with a resistance of 100 or less Green F . G.
Supply Pressure: 0.5MPa (for both brake and driving purposes) d.
D indicates the maximum diameter.
D indicates the maximum diameter.
D-97.D-93A (|& @D D-93A il ! @ D-90 : lnch D-97 Caution. 1) The abovo dimensions may vary in areas whre magnetic Inlerlerence is present. 2) Fo. 14 stroke cylinder, only one aulo switch may be mounted eithgr on the rod end or the cap end. 3) There are two ways to mounl lhe auto swilches as shown in the above ligure.
Compression nut design resists side loading Nut Seal lock F Seal lock E B Tubing support C D A Tubing Taper surface Tube support resists crimping and deformation of tubing.
U, D)-SSL1 Y VQ2000/4000/5000 EX123 (U, D)-SSL2 Y IP53 or NEMA12 comes as optional.
Configuration One thermo-chiller for one master. 2 2 R D R D 3 3 S D S D 5 5 S G S G Master This product Do not connect any wire to other PIN numbers. Fig. 3-12 Connection of RS-232C 3.3 Installation HRR Series 3-20 HRX-OM-X071 Chapter 3 Transport and Setting Up 3.4 Piping Piping port size Connect piping firmly.
entry hole: G1/2 Manual override (Non-locking) 4 x 2-18 mouting hole (80F: 8 x 2-18) Model Applicable flange 65 80 H F E D C B A 1 4 1 4 405.5 441.5 VNC81 -65F VNC91 -80F 65 80 140 150 204 235 175 185 305.5 341.5 210 240 17-4-26 7 Series VNC Coolant Valve: Air Operated/External Pilot Solenoid Precautions Be sure to read before handling.