Male thread Suitable screw torque (Nm) Hexagonal width (mm) Adjustable spanner nominal (mm) 1/4 4.5 M3 M5 10/32-UNF 100 1/6 8 150 7 to 9 14 1/8 200 12 to 14 17 1/4 200 22 to 24 21 3/8 200 28 to 30 24 1/2 1Nm=10.2kgf/cm Tightening torque for lock nuts Caution qSuitable screw torque for a hexagon lock nut is shown in the table below.
DIN terminal Terminal 1 2 + + Pilot Valve Assembly Specifications Grommet (G), Grommet terminal (E), Conduit terminal (T), DIN terminal (D) Electrical entry How to Change Passage State Enclosure Dusttight Lead wire color 100 VAC: Blue, 200 VAC: Red, 24 VDC: Red/Black AC (50/60 Hz) 100, 200, 24, 48, 110, 220, 240 Coil rated voltage (V) 24, 6, 12, 48, 100 DC Allowable voltage fluctuation
VS3135 A01-01 A01-02 A07-52 q Description Electrical entry VS3145 Solenoid cover Body 100 VAC 200 VAC Grommet A12-01 A12-02 A08-52 w e Spool/Sleeve 24 VDC A01-01-63 A01-02-63 A07-52-63 100 VAC 200 VAC Conduit terminal 24 VDC A12-01-63 A12-02-63 A08-52-63 Replacement Parts Material Part no. VS3135 XT019-6 XT013-13-2 XT010-15 Description VS3145 No.
Model VX21 VX22 VX23 2 mm 3 mm Orifice size Orifice size Solenoid Coil 4.5 mm Coil: Class B, Class H 6 mm 8 mm Rated Voltage 100 VAC, 200 VAC, 110 VAC, 220 VAC, 240 VAC, 230 VAC, 48 VAC, 24 VDC, 12 VDC 10 mm 1 2 1 4 3 8 , 1 2 Port size 1 8 1 4 , 1 4 3 8 , Normally Open (N.O.)
,() *() 6 33 () 20 m DC(-)() * ( ) -6No.PS-OMV0003CN-G () CE 0~50(5 ) (FKMHNBR) * 1015 10 1% 1959 LCD * -7No.PS-OMV0003CN-G ISE70 02 L2 M 3 Y K T ISE70 0~1MPa ISE71 0~1.6MPa 02 Rc1/4 N02 NPT1/4 F02 G1/4 2 A A B B :ISO1179-1 IO-Link/1+2 NPNorPNP 1 M12 5m M12 5m L2 S L 1 M SI2 1 2kPaMPa / A ZS-50-A M46 2 B ZS-50-B M46 2 ZS-31-B 5 m M12 ZS-31-C 5 m -8No.PS-OMV0003CN-G M12 4 24
to I08 50-60 Hz Measurement range 0-255 Input impedance >or = 800 kOhms Resolution 8 bits 10 000/256mV Pull-in votage at logic state 1 80V Conversion time 10ms Drop-out volt. at logic state 0 40V Input Voltage 0-10VDC Response time 50ms at 120VAC Input impedance 150 kOhms min.
76 46 66.5 101 66.5 68 99 VCB31 30 50 86 1/2 36.5 13.5 15 32 25 23 M5 8 24 80 46 71 101 71 68 104 22 45 90 1/4, 3/8 41 11 17 36 22.5 23 M5 8 26 84 48 74.5 103 74.5 70 107 VCB41 30 50 94 1/2 41 13.5 17 36 25 23 M5 8 26 88 48 78.5 103 78.5 70 111.5 35 60 102 3/4 41 17.5 17 36 30 28.2 M5 8 26 96 48 86.5 103 86.5 70 119 17-2-27
VN Solenoid valve option Nil Standard Rated voltage 1 2 3 4 5 6 7 8 9 100 VAC 50/60 Hz 200 VAC 50/60 Hz 110 VAC 50/60 Hz 220 VAC 50/60 Hz 24 VDC 12 VDC 240 VAC 50/60 Hz 48 VAC 50/60 Hz Other (Please contact SMC separately.) LVC Select an option mark in page 17-3-9 by Applicable Fluids Check List for special fluids outside of the standard.
Z S L, Z S Note ) PAX 1 1 4 1 2 PB AC Ordering example (Example) Series VXR21, Rc 3/4, 24 VDC, Conduit terminal (Part no.)
Solenoid Specifications 3 (R) 1 (P) 1 (R) 3 (P) Order Made P.2.1-15 13 24 SY1 A 13 24 SY1 Series Grommet (G), (H), L plug connector (L), M plug connector (M) Electrical entry Coil rated voltage (V) DC 24, 12, 6, 5, 3 AC 50/60Hz 100, 110, 200, 220 Allowable voltage 10 to +10% Power consumption (W) (1) DC 0.75W (With light: 0.8W) 0.5W (With light: 0.55W) 0.9 (With light: 1.0) 100V 110V [115V
Recommended Tightening Torque [Nm] Connection thread Pressure Control Equipment 1/2 3/8 1/4 1/8 Torque 28 to 30 22 to 24 12 to 14 7 to 9 2. Avoid excessive torsional moment or bending moment other than those caused by the equipments own weight as this can cause damage. Support external piping separately. 3.
Tightening Torque for Piping Size Wrench tightening angle Tightening torque 1 (25A) 10 to 15 50 to 100 Nm Procedure for installing the valve on the tank Connection thread Proper tightening torque [Nm] Rc1/4 12 to 14 Rc3/8 22 to 24 Rc1/2 28 to 30 Rc3/4 28 to 30 Rc1 36 to 38 Rc1 1/2 40 to 42 5.
Recommended Tightening Torque [Nm] Connection thread Pressure Control Equipment 1/2 3/8 1/4 1/8 Torque 28 to 30 22 to 24 12 to 14 7 to 9 2. Avoid excessive torsional moment or bending moment other than those caused by the equipments own weight as this can cause damage. Support external piping separately. 3.
Series 10-VQD1000 [Option] 4 Port Direct Operated Poppet Solenoid Valve How to Order Valve Clean series Valve option Nil Standard (2 W) V Vacuum (2 W) U For large flow (3.2 W) W For large flow, Vacuum (3.2 W) Energy saving type Rated voltage 5 24 VDC 6 12 VDC Body type 2 Body ported (Single unit) 3 Body ported (Manifold) 5 Base mounted 10 V Q D 1 1 5 1 U 5 L M5 Electrical entry
117 154 AA** 140 181 238 B 160 220 239 C 73 86 92 E 30 38 F 45.5 58.5 75.5 G 40 55 80 J 26 29.5 37.5 K 5 3.5 1.5 M 30 41 50 N 51 64 81 Q 24 35 40 U 5 7 7 V 33 45 50 W 34.5 41 AC21B AC31B AC41B * Without relief valve option ** With relief valve option 2 Series AC21~41 F.R.L.
valve with lamp and circuit of protection of surge voltage of 24 VDC 1.5 W (SMC) Connected load Either of the following conditions: Connection error between units has occurred.
Control and input 24 VDC Class2, 2 A Power supply 24 VDC Class2, 2 A Output Settings Diagnostic size set for the input Mode Content Caution 3 4 24 VDC, 1.5 W or less, DC General per output Output rating 0 OFF OFF Input data only (Default setting) 0 byte Intermediate reinforcing brace (EX600-ZMB1) When handling, assembling or replacing the units: Avoid touching any sharp metal parts of the
Apply a tool Width across flats of attachment Port size Width across flats 3/8 24 mm 1/2 28 mm 3/4 35 mm Turn the pipe 1 41 mm Ensure that the piping is tightened to the required torque. The tightening torque for connection threads is shown in the table below.
JMHZ2-16D mm 16 MPa 0.1~0.7 (oC) -10~60 (mm) 0.01 (c.p.m.) 120 32.7 (N) 43.5 (mm) 10 3 4M40.7 8 3.4 8 2 14 - 4-2.3 V114-5LU (oC) -1050( (ms) ON5 OFF4 Hz 20 / m/s2 150/30 V114-5LU L (L) (V) 24 -1010% (W) 0.4 [0.40.1] P .1367 LED 300 15 - 4-3.
INP 1 INP ON 0.50 -35- 6.3 0.1mm [Nm] mm LEF16 M4x0.7 1.5 6 LEF25 M5x0.8 3.0 8 LEF32 M6x1 5.2 9 LEFS40 M8x1.25 12.5 14 A A mm) mm LEF16 M3 3.5 20 LEF25 M4 4.5 24 LEF32 M5 5.5 30 LEFS40 M6 6.6 31 40mm 6.4 6 /1000km /500 -36- 1. 2. 3. 1. 2. a. b. c. d.