V V V V V N1 NPT1/8 V V V V V V F1 G1/8 V V V V V V 02 Rc1/4 V V N2 NPT1/4 V V F2 G1/4 V V C4*1 4 V V V V C6 6 V V V V V V C8 8 V V N7 1/4" V V V V Straight valve Piping entry direction Rated flow range 1 2 5 10 25 50 100 200 Nil None Straight V V V V V V V V S Yes Straight V V V V V V L None Rear ported V V V V V V V V W Yes Rear ported V V V V V V Symbol Flow adjustment Rear
Number of switches Electrical values: According to switch type, check connection diagram from Section 12.11 2-wire, DC voltage proximity switches: I02 P+F NJ2-12GK-SN Ui: 16 V, Ii: 52 mA 2 I09 P+F NCB2-12GM35-N0 Ui: 16 V, Ii: 52 mA 2 I56 IFM IFC2002-ARKG/UP U: 10-36 V DC, Imax: 150 mA 2 I41 P+F NJ4-12GK-SN Ui: 16 V, Ii: 52 mA 4 3-wire, DC voltage proximity switches: I45 P+F NJ3-18GK-S1N Ui
Set in units of 1% No setting required (same value as pushing force) Pushing speed Speed during pushing operation V V Set in units of 1 mm/s Set in units of 1 mm/s Moving force Force during positioning operation V V Set to 100% Set to (Different values for each actuator) % Area output Conditions for area output signal to turn ON V V Set in units of 0.01 mm Set in units of 0.01 mm No setting
conduit 3-wire (NPN) Solid state auto switch G39C G39 2-wire K39C K39 12 V M9NW V V V v v G59W V V v v 3-wire (NPN) 5 V, 12 V IC circuit Diagnostic indication (2-color indication) Relay, PLC Yes 3-wire (PNP) M9PW V V V v v G5PW V V v v 2-wire 12 V M9BW V V V v v 24 V K59W V V v v Grommet 3-wire (NPN) 5 V, 12 V M9NA** v v V v v 3-wire (PNP) M9PA** v v V v v Water resistant (2
Pulse train signal specifications (Open collector input and differential input are common) 5 s or more 24 V 21.6 V to 26.4 V 5 V 4.75 V to 5.25 V PP3s or less 5 s or more 3s or less 16 s or more 28 - 7.4 Parallel I/O signals (Pulse Input Type) (1) Input side (Pulse input type) Function Description Common terminal for the input signal power supply.
50 MLU 50 40 30 50 40 30 40 ML1C 20 20 [Example] D10 10 5 4 3 5 4 3 -X 202 2 1 100 200 300 400 500 1000 1 100 200 300 400 500 1000 Data Maximum speed: V (mm/s) Maximum speed: V (mm/s) Graph (7) Graph (4) 0.5 MPa P 0.5 MPa P 1000 1000 100 80 500 400 300 500 400 300 63 100 100 80 50 40 80 200 200 63 63 100 100 Load weight: m (kg) Load weight: m (kg) 50 50 50 40 30 50 40 30 40 40 20
(3) 0.4 MPa P < 0.5 MPa 0.4 MPa P < 0.5 MPa 1000 1000 CLQ 100 500 400 300 500 400 300 80 MLGP 100 63 200 200 50 40 80 RLQ Load weight: m (kg) Load weight: m (kg) 100 100 63 50 MLU 50 40 30 50 40 30 40 ML1C 20 20 [Example] D10 10 5 4 3 5 4 3 -X 202 2 1 100 200 300 400 500 1000 1 100 200 300 400 500 1000 Data Maximum speed: V (mm/s) Maximum speed: V (mm/s) Graph (7) Graph (4) 0.5 MPa P
200 Maximum speed V [mm/s] Maximum speed V [mm/s] Graph n Graph c 0.4 MPa P < 0.5 MPa 0.4 MPa P < 0.5 MPa 1000 1000 80 80 100 100 63 63 50 50 40 40 80 80 100 100 100 100 63 63 50 50 Load mass m [kg] Load mass m [kg] 32 32 [Example] 50 50 40 40 32 32 10 10 1 100 500 1000 1 100 500 1000 400 300 200 400 300 200 Maximum speed V [mm/s] Maximum speed V [mm/s] Graph m Graph v 0.5 MPa P 0.5 MPa
Solid state switch Reed switch Yes 5 V A96V A96 Grommet A90V A93V M9NV M9PV M9BV F9NWV F9PWV F9BWV A90 A93 M9N M9P M9B F9NW F9PW F9BW F9BA 100 V 5 V, 12 V 12 V IC circuit Relay, PLC No 2-wire 24 V Yes 3-wire (NPN) 3-wire (PNP) 2-wire 3-wire (NPN) 3-wire (PNP) 24 V 5 V, 12 V IC circuit Grommet 12 V Relay, PLC Yes IC circuit Diagnostic indication (2-color display) 5 V, 12 V Grommet 12 V 2-wire
When auto switches are used, through hole mounting is not available. 4-M3 x 0.5 (Thread for mounting attachment) Adjusting needle for finger speed M5 x 0.8 (Finger closing port) M5 x 0.8 (Finger closing port) 12-8-4 5 Angular Style Air Gripper Standard Type Series MHC2 Double Acting: Size 10, 16, 20, 25 MHC2-20 2-M5 x 0.8 thread depth 8 (Mounting thread) MHZ MHF 4-M5 x 0.8 thread depth 10
When auto switches are used, through hole mounting is not available. 4-M3 x 0.5 (Thread for mounting attachment) Adjusting needle for finger speed M5 x 0.8 (Finger closing port) M5 x 0.8 (Finger closing port) 12-8-4 5 Angular Style Air Gripper Standard Type Series MHC2 Double Acting: Size 10, 16, 20, 25 MHC2-20 2-M5 x 0.8 thread depth 8 (Mounting thread) MHZ MHF 4-M5 x 0.8 thread depth 10
500 400 300 500 400 300 80 80 63 63 100 100 MLGP 200 200 50 50 40 40 80 80 100 100 RLQ 63 63 50 50 Load weight: m (kg) Load weight: m (kg) 32 32 50 40 30 50 40 30 MLU 40 40 32 32 20 20 ML1C [Example] 10 10 D5 4 3 5 4 3 -X 2 2 201 100 200 300 400 500 1000 1 100 200 300 400 500 1000 Data Maximum speed: V (mm/s) Maximum speed: V (mm/s) Graph (7) Graph (4) 0.5 MPa P 0.5 MPa P 1000 1000 100
5 4 3 5 4 3 MNB 2 2 1 100 200 300 400 500 1000 1 100 200 300 400 500 1000 CNA Maximum speed: V (mm/s) Maximum speed: V (mm/s) CNS Graph (6) Graph (3) 0.4 MPa P < 0.5 MPa 0.4 MPa P < 0.5 MPa CLS 1000 1000 100 100 CLQ 500 400 300 500 400 300 80 80 63 63 100 100 MLGP 200 200 50 50 40 40 80 80 100 100 RLQ 63 63 50 50 Load weight: m (kg) Load weight: m (kg) 32 32 50 40 30 50 40 30 MLU 40 40
V Ps + 0.1 293 S = 12.1 log10 () (6) t P + 0.1 T S : Effective area [mm2] V : Air tank capacity [L] t : Discharging time [s] Ps : Pressure inside air tank before discharging [MPa] P : Residual pressure inside air tank after discharging [MPa] T : Temperature inside air tank before discharging [K] Power supply Pressure switch Thermometer Pressure control equipment Control circuit Solenoid
Center trunnion: CS2WT z+ 1 '2 stroke Width across ilats KA 2, P G -! P IRe ,NPT , G) ...,.,l\ With rod boot Width across flats KA , I J I ~ G M ~1<;lL, 1~ '-~ {~ ~~j I" OJ > -~ I ~ ~ rI< I AL ~ ~ " I 0 c ~ c .s.!! ~ H S + Stroke Ji.'.
Voltage Symbol Voltage Applicable size 3E 4E 6E 8E 11E 15E1 Refrigerant R407C (HFC) IDF D 10 Single-phase 100 VAC (50 Hz) 100/110 VAC (60 Hz) V V V V V V 20 Single-phase 200 VAC (50 Hz) 200/220 VAC (60 Hz) V V V V V V 23 Single-phase 230 VAC (50 Hz) V V V V V V Refrigerant R134a (HFC) IDU E Options Symbol *1 Nil C G K L M R S T V Moderate pressure specification *2 With Chinese labels and
Cushion adjustment screw 4 x J GA Air release GA V V Width across flats G Width across flats G MM MM R (max.) d W W D d E E D M MA a a M MA F NA NA F K A A K C H + Stroke S + Stroke H B ZZ + 2 strokes (mm) Bore size (mm) B C A a d E D F G GA J K M MA MM NA P R S T V W H ZZ 0 0.018 0 0.021 0 0.021 0 0.021 0 0.025 0 0.025 0 0.025 0 0.062 0 0.062 0 0.074 0 0.074 0 0.074 0 0.074 0 0.087 40 17
i D l i O l e d o M s t e l t u o l i o f o r e b m u N k r a m e R 4 A V 4 s d n e h t o B 6 A V 6 s d n e h t o B Dimensions/Auto feed tank 0 1 A V 0 1 s d n e h t o B 6 1 A V 6 1 s d n e h t o B 4 B V 4 e d i s e n O 6 B V 6 e d i s e n O 8 B V 8 e d i s e n O s n o i t a c i f i c e p S h c t i w S t a o l F n o i t p i r c s e D 2 ~ 1 0 1 4 S I y t i c a p a C W 5 1 : C D , A V 5 1 :
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 100 500 400 300 200 100 100 500 400 300 200 100 CNA Maximum speed: V (mm/s) Maximum speed: V (mm/s) CNS Graph (6) Graph (3) 0.4 MPa ) P < 0.5 MPa 0.4 MPa ) P < 0.5 MPa CLS 4000 4000 250 CLQ 3000 3000 200 MLGP 2000 2000
mA) PNP: 1.5 V or less (at load current of 80 mA) Response time*5*7 0.25 s/0.5 s/1 s/2 s/5 s Output protection Short-circuit protection Output mode Select from hysteresis mode, window comparator mode, accumulated output mode, or accumulated pulse output mode.