No.CG1*-OM0227-A / / CG1N-Z CG1A-Z CG1N-ZXC85 CG1N-ZX446 P2 1. P4 1-1. 2. P4 2-1. 2-2. 2-3. 2-4. 2-5. 2-6. 2-7. 2-8. 3. P18 3-1. 3-2. 3-3. 3-4. 4. (XC85,X446) P25 4-1. 4-2. PTFE 5. P26 6.
Doc. no.CA2*-OM0240Q PRODUCT NAME Air cylinder (Series compatible with secondary batteries) MODEL / Series / Product Number 25A- Contents Safety Instructions P2 1. Specifications P4 1-1. Specifications 2. Installation and Handling P4 2-1. Air supply 2-2. Design 2-3. Mounting and Installation 2-4. Environment 2-5. Speed control 2-6. Allowable kinetic energy 2-7. Air cushion 2-8.
Doc. no.CG1-OM0001G PRODUCT NAME STAINLESS STEEL CYLINDER MODEL / Series / Product Number C*G5*N**SR / V-* C*G5*A**SR / V-* Contents Safety Instructions P2 1. Specifications P6 1-1. Specifications 2. Installation and Handling P7 2-1. Air supply 2-2. Design 2-3. Mounting and Installation 2-4. Environment 2-5. Speed control 2-6. Cushion 2-7. Control of direction 2-8. Auto switches 3.
No.CG1*-OM0006N / / C*G5*N**SR/V-* C*G5*A**SR/V-* P2 P4 1. P6 1-1. 2. P7 2-1. 2-2. 2-3. 2-4. 2-5. 2-6. 2-7. 2-8. 3. P16 3-1. 3-2. 3-3. 3-4. 4. P24 5.
Compatible Power supply Nil Without cable drivers voltage [V] 25 32 40 S Standard cable Nil Without driver R Robotic cable A1 LECSA1-S 100 to 120 (Flexible cable) A2 LECSA2-S 200 to 230 Cable length[m] B2 LECSB2-T 200 to 240 Nil Without cable C2 LECSC2-T 200 to 230 2 2 S2 LECSS2-T 200 to 240 5 5 N2 LECSN2-T 200 to 240 A 10 E2 LECSN2-T-E 200 to 240 92 LECSN2-T-9 200 to 240 I/O cable length P2
C2 LECSC2T S2 LECSS2T N2 LECSN2T 92 LECSN2T-9 E2 LECSN2T-E P2 LECSN2T-P -4- 1.1.2 Specification LESYH*(D,R,L)*S2/S3 Motor type S2/S3 Model LESYH16*S2 LESYH25R/LS3 LESYH25DS3 Parallel In-line Stroke[mm] 50,100 50,100,150 50,100,150 Horizontal 8 12 12 Max. work load [kg] Vertical 6 12 10 20 10 20 Force [N] (Set value: 15 to 30%) *1 65 to 131 127 to 255 79 to 157 154 to 308 98 to 197 192 to
Doc. no.CV3*-OM0040-B PRODUCT NAME cylinder MODEL / Series / Product Number N Contents Safety Instructions P2 1. Specifications P4 1-1. Specifications 1-2. Power consumption 2. Installation and Handling P5 2-1. Air supply 2-2. Design 2-3. Mounting and Installation 2-4. Environment 2-5. Changing between rod extended when energized and rod retracted when energized 2-6.
Safety Instructions -P2 3. Safety InstructionsOutline -P8 4. Specifications -P8 5. Operation Principle -P9 6. Trouble shooting -P10 7. Disassembly / Assembly Procedure -P11 1 Safety Instructions These safety instructions are intended to prevent hazardous situations and/or equipment damage.
63No.EX-OMQ0016 EX600 setup (1)Click the EX600-SPN# icon in the [HW Config] screen. (2)The [Properties] screen will be displayed by double-clicking the [Interface] of the [Configuration table] window [Slot X1]. (3)Tick the box for [Prioritized startup] in the [General] tab. (4)Press the [OK] button. (2) (3) (4) (5)The [Properties] screen will be displayed by double-clicking the Slot1 P1 or P2
How to Calculate Flow Rate IP67 Enclosure Conversion with sonic conductance C: S=0.5XC Q : Air flow rate [dm3/min(ANR)] S : Effective area [mm2] P1 : Upstream pressure [MPa] P2 : Downstream pressure [MPa] t : Temperature [] Wiring connection for models conforming to IP67 should also have enclosures equivalent to or of stricter than IP67. 11 No.VQC1000V-OMM0002-B VQC1000/2000 series Specific
CM1 For flat ribbon cable: IDC connector CM2 For round cable (VCTF): Terminal block connector CM3 For IDC connector: Branch connector EX9-CP2 Power supply connector P2 Straight type (Attached the product.) P3 T-branch type : EX9-CP3 is not included with the product. Please order separately. -7No.EX-OMM0008-D Summary of Product parts EX120 series EX121 series EX122 series No.
. *1) (m) ACCEL Reverse acceleration switch (o) P2 16 reverse acceleration steps are available. *1) (n) Power supply connector Connect the power supply cable. (o) CN1 (p) CN2 Motor driving connector Connect motor connector of actuator cable. (q) CN3 Encoder connector Connect encoder connector of actuator cable.
Example S2S2 Standard cable (2m) + driver (LECSS22) P2 LECSN2-T9-P/PROFINET Absolute encoder 200V230V S2 Standard cable (2m) Nill Without cable/driver Applicable stroke table* Size Stroke[mm] 100 200 300 400 500 600 700 800 900 1000 Manfacturable stroke range 100 100 to 1000 *Please consult with SMC for non-standard strokes as they are produced as special orders. -11- 2.3 Construction
Doc. no.C96*-OM0001Q PRODUCT NAME Air cylinder MODEL / Series / Product Number Contents Safety Instructions P2 1. Specifications P4 1-1. Specifications 2. Installation and Handling P4 2-1. Air supply 2-2. Design 2-3. Mounting and Installation 2-4. Environment 2-5. Speed control 2-6. Allowable kinetic energy 2-7. Air cushion 2-8.
Contents Contents P1 Safety Instructions P2 Handling precautions P4 Wiring method and LED indication P6 System configuration P7 Communication specification P7 Setting of dipswitch P8 Pressure setting and output monitoring P10 Communication data P10 Maintenance and inspection P11 1 - E/P Regulator Safety Instructions These safety instructions are intended to prevent hazardous situations and
Contents Contents P1 Safety Instructions P2 Handling precautions P4 Wiring method and LED indication P6 Communication specification P7 Pressure setting method P7 Communication protocol P8 Maintenance and inspection P9 1 - E/P Regulator Safety Instructions These safety instructions are intended to prevent hazardous situations and/or equipment damage.
Contents Contents P1 Safety Instructions P2 Handling precautions P4 Wiring method and LED indication P6 System configuration P7 Communication specification P7 Setting of dipswitch P8 Pressure setting and output monitoring P9 Communication data allocation P10 Maintenance and inspection P11 1 - E/P Regulator Safety Instructions These safety instructions are intended to prevent hazardous situations
No.VQ1000V-OMM0002-B 10 - VQ1000/2000 series Specific Product Precautions 3 Be sure to read this before handling How to Calculate Flow Rate Conversion with sonic conductance C: S=5.0XC Q : Air flow rate [dm3/min(ANR)] S : Effective area [mm2] P1 : Upstream pressure [MPa] P2 : Downstream pressure [MPa] t : Temperature [] No.VQ1000V-OMM0002-B 11 - When the valve is failing, use this flow chart
Doc. no.CG1*-OM0065P-B PRODUCT NAME Air cylinder MODEL / Series / Product Number N N N Contents Safety Instructions P2 1. Specifications P4 1-1. Specifications 2. Installation and Handling P4 2-1. Air supply 2-2. Design 2-3. Mounting and Installation 2-4. Environment 2-5. Speed control 2-6. Allowable kinetic energy 2-7. Control of direction 2-8. Auto switches 3. Maintenance P19 3-1.
Doc. no.CA2*-OM0071P-B PRODUCT NAME Air cylinder MODEL / Series / Product Number / Contents Safety Instructions P2 1. Specifications P4 1-1. Specifications 2. Installation and Handling P4 2-1. Air supply 2-2. Design 2-3. Mounting and Installation 2-4. Environment 2-5. Speed control 2-6. Allowable kinetic energy 2-7. Air cushion 2-8.