specification] Terminal block A D (159) 250 4-13 C Drain port Rc 1/4 278 450 65 [100VAC specification] Power cord Auto drain is packed together with air dryer.
Remarks Weight With lead wire and M12 connector LFE-1-A3 Lead wire length: 3 m Approx. 175 g LFE-1-D Tapping screw 3 x 10, 4 pcs. Approx. 45 g Bracket LFE-2-D Tapping screw 3 x 10, 4 pcs. Approx. 70 g LFE-3-D Tapping screw 3 x 10, 4 pcs.
30 40 13 XL-OMY0002 8 X L D 25 M9N A A ( X A N1 A ) 25 40 B A 50 63 80 C P11 160 100 FKM() P8 KF (NW) D K (DN) () A / A F G A J B K C L M M9N D-M9N M9P D-M9P / 560 M9B D-M9B A90 D-A90 H0 H4 H5 5150 100 A93 D-A93 120 M9// 25H4 14 XL-OMY0002 9. 200 2580 100 100,160 [] 1 1.5 1 XLD-25,XLD-40,XLD-50,XLD-63,XLD-80 200 XLD-100,XLD-160 100 : FKM 110 Pa <> 15 XL-OMY0002
Operation/ Shutdown 3.10.6 PID manual setting CH1 PID (control parameter) P Proportion band (050) i Integral time (051) d Derivative time (052) PID(proportion band / integral time / derivative time) is manually set. [ Setting range] P: 0.1 to 999.9 I: 0 to 3200 sec. D: 0.0 to 999.9 sec. PID values are automatically set by auto tuning.
Consult with SMC regarding water resistant types with the above model numbers. * Solid state auto switches marked with are produced upon receipt of order. ** Since D-A9and D-A9V cannot be mounted on 50, use of D-Z7 or D-Z80 is recommended. * Lead wire length symbols: 0.5 m Nil (Example) M9NW 1 m M (Example) M9NWM 3 m L (Example) M9NWL 5 m Z (Example) M9NWZ D* Since there are other applicable
D-A9V Solid state switches D-F9 D-F9V 2 color indication solid state D-F9W D-F9WV MXQ 6 MXQL 6 6 MXQ 8 MXQL 8 8 MXQ12 MXQL12 12 MXQ16 MXQL16 16 MXQ20 MXQL20 20 MXQ25 MXQL25 25 Function Options Adjuster Options With Buffer Mechanism With End lock Protects work pieces and tools, etc., by eliminating impact at the end of the extension stroke Buffer unit is auto switch capable Holds
[%F.S.] 2 1 0 OUT OUT OUT OUT 0 D 2D 3D 4D 5D IN IN IN IN 0 1 2 3 4 5 5 (5D) [] [] LFE13/8 inch 0.2 MPa LFE23/4 inch LFE31 inch (mm) D 5 D LFE1 11 55 LFE2 21 105 LFE3 27 135 68 No.LFE*-OMY0008 4.0 3.5 3.0 2.5 [%F.S.]
Option Part number Remarks Weight With lead wire and M12 connector LFE-1-A3 Lead wire length: 3 m Approx. 175 g LFE-1-D Tapping screw 3 x 10, 4 pcs. Approx. 45 g Bracket LFE-2-D Tapping screw 3 x 10, 4 pcs. Approx. 70 g LFE-3-D Tapping screw 3 x 10, 4 pcs.
Type T: 4.5 to 7 mm Type E: 2.3 to 2.8 mm Type D: 6 to 8 mm Applicable crimp terminal Type E/T: 1.25-3, 1.25-3S 1.25Y-3N, 1.25Y-3S Round or Y shaped crimped terminals can be not used for type D.
VQ VKF Surge voltage suppressor mounting part (For G) VQZ VZ VS VFN Surge voltage suppressor Electrical entry G Grommet, 300 mm lead wire H Grommet, 600 mm lead wire C Conduit JIS Symbol T Conduit terminal D DIN terminal Rated voltage 50 60 1 2 3 100 VAC, Hz 200 VAC, Hz 110 VAC, Hz 220 VAC, Hz 50 60 50 60 4 50 60 5 6 24 VDC 12 VDC 7 240 VAC, Hz 50 60 9 Other Option Manifold Accessory
Fluid Table (1) Rated Voltage-Electrical Entry-Electrical Option Standard specifications Option (1) Made to Order (2) Water (standard) Turbine oil High temperature water (D, E) Air X500B Vacuum (up to 1.3 x 10 2 Pa) X500B For pure water X500 G C Class B D, T Class H G, C T S Note) S L, Z L, Z S Note) Surge voltage suppressor is attached in the middle of lead wire.
IR : Combination not available : Available only with NPT thread : Combination available : Varies depending on the model Accessory/Optional Specifications Combinations VEX Applicable micro mist separator Optional specifications Accessory Symbol Combination AFD20 B C D 2 6 8 C J R Z W AFD30 to 40 AMR Accessory/Optional specifications B C D Accessory Optional specifications With bracket ITV
JOG operation positioning operation programmed operation DO forced (Note 4) 0 0. b output single-step feed (Note 4) Test operation mode # #. d (Note 1) Motor-less operation # #.
(3 positions) Controller detail General 3 positions 5 positions General A 1 2 5 7 State of indicator light D B C E 8 3 4 6 Switch No.
Enter in order starting from the first station on the D side.
Add the symbol at the beginning of part numbers for solenoid valves, etc. to be mounted, and enter these together in order from the D side.
(Atlanta) 1440 Lakes Parkway, Suite 600 Lawrenceville, GA 30043 Tel: (770) 624-1940 FAX: (770) 624-1943 16850 W. Victor Road New Berlin. Wl 53151 Tel: (414) 827-0080 FAX: (414) 827-OO92 5377 Glen Alden Drive Richmond, VA 23231 Tel: (804) 222-2762 FAX: (80a) 222-5221 SMC Pneumatics Inc.
For the D-P3DW;, refer to the catalog CAT.ES20-201. The D-A9;/M9;;;/P3DW; auto switches are shipped together, (but not assembled).
(mg/m3) 0.1 d 0.5 0.5 d 1.0 1.0 d 5.0 point() 1 20,000 400 10 1 -70 1 0.01 2 400,000 6,000 100 2 -40 2 0.1 3 Not specified 90,000 1,000 3 -20 3 1 4 Not specified Not specified 10,000 4 +3 4 5 5 Not specified Not specified 100,000 5 +7 6 +10 3.3.2 Air pressure 1) Operation with a pressure exceeding the maximum operating pressure leads to breakage of the product.