This is equivalent to a field in a radius of about 18 cm from a welding part using welding current of about 15000 amperes.

Use formula as shown below : Load(kg) Bore size(cm)xr2x xOperating Pressure(Mpa) 4 Bore size:40cm Load : 20kg(Allowable kinetic Energy) Operating Pressure : 0.5MPa 20kg 4x4x x0.5 x1000=31.8=30% 4 P6 No. of Brake operation P7 Origin Detection Time Set the Origin Detection time(t1) (10ms as 1 unit, maximum will be 9.99s) After inputting the homing (returning to origins) signal.

LCDON LCDOFF 44 11-1 11-1-1 P1 P2 () P39 Err9( 9 P4 P5 kg cm)r MPa 4 <>40 20kg 0.Pa 20 440.5 100031.830 4 P6 P7 10ms 9.99sec () (, ON ON P8Err12 * *10msec 9.99sec *() (, * 11-1-2 PRESET " PRG STEP P1 " P1 1000.0 " " 45 WRITE READ UPDOWN LEFTRIGHT WRITE 1 PRG STEP P1 1000.0 " " " " UP 1000.0 DOWN RICHT LEFT 2P2 P2 () 9.9mm PRG STEP P2 1.0 " " " " <> 1.0 1.0

Table 7-1 Water Quality Standards Substance Facility water Circulating water spec. spec. pH (25C) 6.5 to 8.2 6.0 to 8.0 Electrical conductivity (25C) (s/cm) 100 to 800 0.5 to 300 Chloride ion (mgCl-/L) Max. 200 Max.50 Sulfate ion (mgSO42-/L) Max. 200 Max.50 Acid consumption (pH4.8) (mgCaCO3/L) Max. 100 Max.50 Total hardness (mgCaCO3/L) Max. 200 Max.70 Calcium hardness (mgCaCO3/L) Max. 150

EX12#-SMJ1 Applicable system CC-Link Ver.1.10 Occupied station 1 station Station number setting range 1 to 64 (Set with a rotary switch) Communication specification Station type Remote I/O Communication speed 156 k/625 k/2.5 M/5 M/10 Mbps Cable length between stations 20 cm or more Max. cable length 1200/900/400/160/100 m Communication supply voltage 15 to 30 VDC Solenoid valve supply voltage

Higher-level bus Compatible system CC-Link Ver. 1.10 Number of station occupied 3 stations (for setting with input point 64/output point 64) 2 stations (for setting with input point 32/output point 32) Station type Remote device station Communication speed 156 Kbps 625 Kbps 2.5 Mbps 5 Mbps 10 Mbps Cable length between stations 20 cm and over Maximum extended cable length 1200 m 900 m 400

output signals and serial transmissions. (3) Keep signal wires away from the power cables in wiring. (4) When cables may cause radiation noise, mount a ferrite core on a signal cable. (5) Use another stable power source for CEU5 power supply, separate from motor and solenoid valve for AC type. (6) Mount a noise filter for possible noise effects of power source. (7) Keep relays at least 10 cm

. -20No.EX-OMO0007-E Specifications Table of specifications Item Specifications Applicable system CC-Link Ver.1.10 Network communication Occupied number of stations 1 node specifications Allowable node number setting 1 to 64 Station type Remote I/O node Transmission speed 156 kbps 625 kbps 2.5 Mbps 5 Mbps 10 Mbps Min. cable length between nodes 20 cm or more Max. total cable length 1200 m

Table 7-1 Quality standard for fresh water (tap water) Item Product Standard value For circulating fluid pH (at 25oC) 6.0 to 8.0 Electric conductance (at 25oC) [S/cm] 100 to 300 Chloride ion [mg/L] 50 or less Standard Sulfuric acid ion [mg/L] 50 or less item Acid consumption (at pH 4.8) [mg/L] 50 or less Total hardness [mg/L] 70 or less Calcium hardness [mg/L] 50 or less Ion silica [mg/L

Table 2-1 Quality standard for fresh water (tap water) Item Standard value pH (25oC) 6.5 to 8.2 Electric conductivity (25oC) (S/cm) 100 to 800 Chloride ion (mgCl-/L) 200 or less 2-/L) 200 or less Sulphate ion (mgSO4 Acid consumption (pH4.8) (mgCaCO3/L) 100 or less Total hardness (mgCaCO3/L) 200 or less Calcium hardness (mgCaCO3/L) 150 or less Quality item Ion silica (mgSiO2/L) 50 or less

Usable stroke by buckling strength Usablestroke by Mounting style Pressur buckling strength (cm) e Symbol and sketch Symbol 125 140 160 180 200 250 320 (MPa) of bracket Rod side 0.3 103 92 113 108 124 155 162 Head L Foot: side Frang flange e F 0.5 79 70 86 81 94 118 122 L G F 0.7 66 58 72 67 78 98 101 0.3 45 38 47 46 54 67 69 0.5 33 27 34 33 39 49 49 G 0.7 26 22 27 26 31 39 39 0.3 96 83

Table 7-1 Water Quality Standards for Fresh Water (Tap Water) Substance Facility water Circulating water spec. spec. pH (25C) 6.5 to 8.2 6.0 to 8.0 Electrical conductivity (25C) (s/cm) *Circulating fluid 1 to 500 100 to 800 0.5 to 300 Chloride ion (mgCl-/L) Max. 200 Max.50 2-/L) Max.200 Max.50 Sulfate ion (mgSO4 Acid consumption (pH4.8) (mgCaCO3/L) Max.100 Max.50 Total hardness (mgCaCO3/L

When port plug is used on 2(B) port, indicate CM in manifold port no. and port size, and specify the port plug location in the manifold specification sheet. 11 No.VQZ100V-OMK0002-B VQZ Series/ / / /Specific Product Precautions 4 Be sure to read this before handling Changing the One-touch fitting DIN Rail Removal/Mounting The built-in fittings on the manifold can be changed easily.

This is equivalent to a field in a radius of about 18 cm from a welding part using welding current of about 15000 amperes.

(Refer to P.15 10 2-2) Actuating force The actuating force of sine rodless cylinder is ideally equal to thrust at center of axis of piston but normally, Distance from center of axis Lo of cylinder as shown on Fig.6-1, it is taken as FnN at the part away Recommended actuating force from the center by Lo cm.

Grease pack part number: GR-S-010(10g) , GR-S-020 (20g) Wear ring number 32 CM-32-07-304B 40 C1A040-07-305B 50 C1A050-07-306B 63 CA1063-07-307B 80 C1A080-07-308B 100 C1A100-07-309B 125 C1S125-07-362 C a u t i o n The seal is not delivered in sealed packaging for storage independently, so it must be used within 1 year. 3-3-2.

slider increases and causes wearing to wear so much as to induce operating failure. 8 Actuating force and moment 2-1) Actuating force The actuating force of rodless cylinder is ideally equal to thrust at center of axis of piston but normally, as shown Distance from center of axis Lo of cylinder on Fig. 5-1, it is taken as FnN at the part away from the Recommended actuating force center by Lo cm

P+0.1 0.1 QCR = V x x 10 3 (1) P 0.1 (2) QCP = a x L x x 10 6 Formula QCR = Amount of air consumption of rotary table [L(ANR)] Qc2 = Qc x n x No. of actuators x Margin rate QCP = Amount of air consumption of tube or piping [L(ANR)] V = Inner volume of the rotary table [cm 3] Qc2 = Amount of exhaust air from a compressor [L/min (ANR)] n = Actuator oscillations per minute P = Operating pressure

Locking direction Bore size F B Extension locking Retraction locking 50 63 80 100 20 25 32 40 20mm 25mm 32mm 40mm 50mm 63mm 80mm 100mm Body option Nil C M CM Standard (rod end female threads) With rubber bumper Rod end male threads With rubber bumper, Rod end male threads Cylinder Stroke (mm) Refer to page 2 for standard strokes and intermediate strokes.

P + 0.1 0.1 QCR = 2V x x 10P 0.1 QCP = 2 x a x l x x 10QC = QCR + QCP Formula QC2 = QC x n x Number of actuators x Reserve factor QCR = Air consumption of Mini-Rotary Actuator [l (ANR)] QC2 = Compressor discharge flow rate n = Actuator reciprocations per minute QCP = Air consumption of tubing or piping [l (ANR)] V = Internal volume of Mini-Rotary Actuator [cm] Internal cross section of tubing