SMC Corporation of America
Elite Part Number Search
Search Results "CHD2EFB63C-100-F-M9PSAPC"

Stroke (mm) Up to 10 Up to 30 Up to 50 Up to 75 Up to 100 Max. speed (mm/s) Up to 100 Up to 300 Up to 400 Over 400 Up to 100 Up to 300 Up to 400 Over 400 Up to 100 Up to 300 Up to 400 Over 400 Up to 100 Up to 300 Up to 400 Over 400 Up to 100 Up to 300 Up to 400 Over 400 6 (7) (8) (9) 10 15 Selection graph 20 (10) (11) (12) (13) (14) (15) (17) (16) 25 32 The maximum speeds for 10 to 32 are

F A A MXH Lr MXF16 MXU Lr = 40 mm 0.07 0.07 0.20 MXS Table displacement amount (mm) Table displacement amount (mm) Table displacement amount (mm) 0.06 0.06 MXF16-75 MXQ 0.16 MXF16-75 MXF16-75 MXF16-50 MXF16-30 0.05 0.05 MXF 0.12 0.04 0.04 MXF16-50 MXW MXF16-50 0.03 0.03 0.08 MXF16-30 0.02 0.02 MXJ MXF16-30 0.04 0.01 0.01 MXP 0 0 20 40 60 80 100 20 40 60 80 100 120 60 0 40 80 100 20 MXY Load

R(D)QB40-20 -25 -30 -40 -50 -75 -100 R(D)QB50-30 -40 -50 -75 -100 9 8 9.5 13.5 10 3 Compact Cylinder with Air Cushion Double Acting: Single Rod Series RQ Auto Switch Mounting Bracket Part Nos.

selection function Note 12) NPN 2 outputs F SI unit only Note 13) -100 to 100 H PNP Unit selection function Note 12) 2 outputs J SI unit only Note 13) K Unit selection function Note 12) NPN Pressure switch for 1 output Q SI unit only Note 13) -100 to 100 vacuum with energy R PNP Unit selection function Note 12) saving function Note 11) 1 output S SI unit only Note 13) N Without pressure

2,4,6,8... 85 + 30 (n2) n = 2,4,6,8... 95 + 100 (n2) n = 2,4,6,8... 100 + 100 (n2) n = 2,4,6,8... 105 + 100 (n2) n = 2,4,6,8... 110 + 100 (n2) n = 2,4,6,8... 90 + 30 (n2) n = 2,4,6,8...

Action D Double acting Mounting Cylinder stroke Through hole & Double end tapped (Standard) Foot type Front flange type Rear flange type Double clevis type B L F G D Note) Bore size (mm) Standard stroke (mm) 10 10, 20, 30, 40 16 10, 20, 30, 40, 50, 60 20 10, 20, 30, 40, 50, 60 Note) Available only for MQQL. 25 10, 20, 30, 40, 50, 75, 100 Mounting brackets are included when shipped, but unassembled

M1 = F x L A M2 = F x L M3 = F x L Note) Deflection: Displacement of section A when force acts on section F REBH15, 25 REBH15, 25 REBH15, 25 REBH15 REBH15 REBH25 REBH15 REBH25 0.08 0.03 REBH25 0.02 Deflection (mm) Deflection (mm) Deflection (mm) 0.06 0.02 0.04 0.01 0.01 0.02 5 10 15 20 0 25 25 5 10 15 20 0 5 10 15 20 0 25 Moment (Nm) Moment (Nm) Moment (Nm) REBHT25, 32 REBHT25, 32 REBHT25

AF F F E E B C AR Cross spacer E: 4 x Rc F: Without thread E D A AL A 23 B 16 C 14 D 25 Applicable model AC10 Model Y14-M5 Y24-01 Y24-02 Y34-01 Y34-02 Y44-02 Y44-03 Y54-03 Y54-04 Port size M5 1/8 1/4 1/8 1/4 1/4 3/8 3/8 1/2 AW AC20 40 40 22 40 AG AC25, AC30 49 43 28 48 AV AC40 60 48 36 54 AF800 AF900 Caution on Mounting AC40-06 72 62 40 62 1.

Deflection on A when load is applied on F. Table deflection when yawing moment is applied. Deflection on A when load is applied on F. Table deflection when roll moment is applied. Deflection on A when load is applied on F.

selection function Note 12) NPN 2 outputs F SI unit only Note 13) -100 to 100 H PNP Unit selection function Note 12) 2 outputs J SI unit only Note 13) K Unit selection function Note 12) NPN Pressure switch for 1 output Q SI unit only Note 13) -100 to 100 vacuum with energy R PNP Unit selection function Note 12) saving function Note 11) 1 output S SI unit only Note 13) N Without pressure

Table 8-1 Quality standard for clean water (tap water) Standard value Item Unit For circulating fluid For facility water pH (at 25oC) 6.0 to 8.0 6.5 to 8.2 Electric conductance (at 25oC) [S/cm] 100 to 300 100 to 800 Chloride ion [mg/L] 50 or less 200 or less Sulfuric acid ion [mg/L] 50 or less 200 or less Standard item Acid consumption (at pH 4.8) [mg/L] 50 or less 100 or less Total hardness

Accelerating torque calculation (Example) (Example) Friction coefficient Ta = I x (Nm) Mass m F = mg Clamp F F I : Inertial moment Static torque calculation Movement Load Refer to features page 5. : Angular acceleration = (rad/s) Tf = F x l (Nm) g = 9.8m / s F: Pressing force (N) l l Static torque calculation 2 Load t2 Ts = F x l (Nm) Lever : Rotation angle (rad) t : Rotation time

N 0.5MPa 0.5MPa 40 40 0.4MPa 0.4MPa F 0.3MPa 0.3MPa 20 20 0.2MPa 0.2MPa 0 0 10 10 20 20 30 30 40 40 Gripping point L mm Gripping point L mm MHS2-25D MHS2-25D 100 100 F Internal gripping Pressure 0.6MPa Pressure 0.6MPa 80 80 Gripping force N Gripping force N 0.5MPa 0.5MPa 60 60 Note: 1N = 0.2248lbf 1in = 25.4mm 1MPa = 145psi 0.4MPa 0.4MPa 40 40 0.3MPa 0.3MPa 0.2MPa 0.2MPa 20 20 0 0 10 10

Note 5) If the compressor is small (0.75 kW, discharge flow is less than 100 L/min[ANR]), air leakage from the drain cock may occur during start of operations. N.C. type is recommended. 18 6.

V to +400 V +30 V to +100 V Within 30 V 30 V to 100 V 100 V to 400 V 400 V or lower Light ON Positive Static neutralization completion Flash at 4 Hz Detects the electric potential difference and outputs in an analog voltage.

Magnet: D (Built-in Magnet), Series: A2, Mounting: L (Axial Foot), Tube Material: Aluminum Tube, Bore Size: 63mm, Port Thread: Rc, Stroke: 100mm, Rod Boot: w/o Rod Boot, Auto Switch: M9P--Solid State, Gen. Purpose, 3 Wire PNP, Horizontal, Lead Wire or Prewired Connector: SAPC (0.5m Cord Length, M8-3 Pin Connector)

Magnet: D (Built-in Magnet), Series: A2, Mounting: L (Axial Foot), Tube Material: Aluminum Tube, Bore Size: 80mm, Port Thread: Rc, Stroke: 100mm, Rod Boot: w/o Rod Boot, Auto Switch: M9P--Solid State, Gen. Purpose, 3 Wire PNP, Horizontal, Lead Wire or Prewired Connector: SAPC (0.5m Cord Length, M8-3 Pin Connector)