VQ1000-FPG-C4M5-D: 6 sets Double check block 757 S0700 Series Construction Body Ported Construction 2(B) (A)4 S0716 2-Position Single r u e w q 3(R2) (R1)5 1 (P) t y i 2-Position Double S0726 2(B) (A)4 r u e w q 3(R2) (R1)5 1 (P) t y i 3-Position Closed Center S0736 r u e w q 2(B) (A)4 (R1)5 1 (P) 3(R2) t y i 4-Position Dual 3-Port Valve S07A6 r u e w q 2(B) 4(A) 5(R1) 3(R2) 1(P) N.C. + N.C
Bore size [mm] 10 16 20 25 Fluid Air Action Double acting A large amount of gripping force is provided through the use of a double piston mechanism, while maintaining a compact design.
Series 25 19 dB (A) Page 5-10-4 VEX AN101-01 AN110-01 AN120-M5 AN120-M3 BC sintered body type Ideal for the exhaust of a compact valve or pilot air. 16 dB (A) 21 dB (A) 18 dB (A) 13 dB (A) 100 m AN Page 5-10-5 Silencers Exhaust Cleaner 70 m AMC One-touch fitting connection type Can connect with One-touch fitting directly. 25 dB (A) 30 dB (A) It differs depending upon the model.
(I$odell A A I D E t H WT $tl oEfio.l il{s} 57.0 6i.0 l(10 x 1.0 3.0 N/A 8.6 49.4 8.6 10.? N/A r{/A N/A 0 t.t5rir(B) 8 t . 8 91.1 Ml2 x 1.0 3.3 l.l/A 8,6 71.4 0.9 14.2 N/A .0 9.7 (r.R)0Efl.251rr(r)8r.8 9 1 . ? M l { x 1 . 5 J.J /A 1.2 71.4 0.9 t4.2 N/A r2.0 12.1 (r.R)0Efti.35rJr(Bl 100,6 0.7 l l 6 x 1 . 5 4.0 N/A ).2 87.4 1.2 t4.5 0.5 t4.0 12.7 l0 [.5t](B] 9E_6 I t 0,5 [!
/N.C.) 1500 mm 4(A) 2(B) 2000 mm A Note 2) 3000 mm 10 mm Semi-standard 5(EA) 3(EB) 1(P) Electrical entry 4-position dual 3 port valves (N.O./N.O.) 2(B) 4(A) Symbol Electrical entry B Note 2) L-type plug connector Pilot type Nil R L Internal pilot 5(EA) 3(EB) 1(P) 4-position dual 3 port valves (N.C./N.O.)
Stabilize the source pressure by providing a tank and a vacuum regulator. Provide a vacuum switch valve to individual lines.
Applicable cylinder bore size (mm) Elbow type Universal type Port size Metric size Inch size 12 10 8 6 4 3.2 1/8" 5/32" 3/16" 1/4" 5/16" 3/8" 1/2" AS131FG-M5 AS121FG-M5 M50.8 6, 10, 16, 20 AS231FG-01 AS221FG-01 20, 25, 32 R 1/8 AS231FG-02 AS221FG-02 20, 25, 32, 40 R 1/4 AS331FG-02 AS321FG-02 40, 50, 63 R 1/4 AS331FG-03 AS321FG-03 40, 50, 63 R 3/8 AS431FG-04 AS421FG-04 63, 80, 100 R 1/2
(Ex.) 972A.2003 50411 (Matsuo Electric Co.,Ltd. 200VAC rating) Outline drawing [Unit: mm] Rated voltage C [ F] R [ ] Test voltage AC[V] Vinyl sheath AC[V] 18 1.5 Blue vinyl cord Red vinyl cord 200 0.5 50 Across 6 (1W) T-C 1000(1 to 5s) 10 or less 10 or less 4 10 3 10 3 15 1 31 200 or more 200 or more 48 1.5 Note that a diode should be installed to a DC relay, DC valve or the like.
tubing O.D.Q I 5 H R J F Hexagon width across flats 10 Hexagon width across flats 2 E Hexagon width across flats 12 Applicable tubing O.D.Q D C Y 2 R H A B Hexagon width across flats 12 Hexagon width across flats 3 F E D C 3 2 Dimensions: 10 mm Stroke A A B (mm) B C D E F H I J Model ZPR10F10-0-A10 10 12 10 12.5 23.4 39.5 50.5 84.5 Stroke: 10 mm ZPR13F10-0-A10 13 15 23 10.5 13 23.9 40 51
P80601 1 Faoltcrir*rl coll-A-c. solanold l lli/1m V 3y60 Ha. 120t60 Nt@ aa)a) qIA{S c01ar0 qIA.11 10 '| Solanold str. n!
Basic type Select type Model VEX5504 06 10 VEX57-10 12 VEX59-14 20 P1 P1 VEX VEX Description Bracket (With bolt and washer) G46-10-01 VEX7-32A VEX5-32A VEX9-32A Air operated External pilot solenoid valve 3(R) 3(R) Pressure gauge 1(P) 3(R) 3(R) 1(P) P2 P2 P3 P1 P1 3(R) 3(R) 3(R) 3(R) 1(P) 1(P) P2 P2 Note) With this valve, the port 3(R) is a supply port and port 1(P) is an exhaust port. 2441
R 30 - PNP type (LECPAP-) Power supply for pulse signal Positioning unit side Inside of the driver Current limiting resistor R NP+ <3> 1k NP<4> 120 Current limiting resistor R PP+ <5> 1k PP<6> 120 Caution Be sure to install a current-limiting resistor R according to the pulse-train signal voltage.
D-A5/A6 Same side 10 110 110 115 125 135 145 1 pc. 10 Different sides 20 2 pcs. D-A59W Same side 20 115 115 125 130 140 150 1 pc. 15 Different sides 10 2 pcs. D-F5/J5 Same side 10 115 115 120 130 140 150 1 pc. 10 Different sides 10 2 pcs. D-F5W/J5W D-F5BAL Same side 10 120 120 120 135 140 150 1 pc. 10 Different sides 10 2 pcs.
C 1 B A Basic (mm) (mm) T 9 10.5 MKB20-Z MKB25-Z Model Yh9 18 23 A B C E F G 36 40 47 52 36 40 35.5 40.5 18 21 17.9 22.5 S 28 27.5 Clamp stroke Model Rod state 0 0.043 0 0.052 20 mm Q R 112.5 142 113.5 143 30 mm Q R 132.5 172 133.5 173 10 mm Q R 92.5 112 93.5 113 Retracted Extended Retracted Extended MKB20-Z 72 82 92 MKB25-Z 73 83 93 Note) The above figure is with the auto switch (D-M9) mounted
Seal kit includes a grease pack (10 g). When !5 or !6 is shipped independently, a grease pack (20 g) is included. Order with the following part number when only the grease pack is needed. Grease pack part number: GR-S-010 (10 g), GR-S-020 (20 g) D-X Technical Data 1213 A MY1H Series Construction End lock !9 @2 @0 @1 e w !5 !6 !3 !2 !1 !0 q t r i S u y o !4 !8 !
0.07 A 0 0.00 0.88 (22.4) 0 20 40 60 80 Flow rate (slpm, N2) 2 x 10-32 UNF depth 0.25 (6.3) (Mounting hole) Connections inch A (mm) FV4 MV4 FV6 MV6 TW6 3.70 (94.0) 4.70 (119.4) 2.96 (75.2) Hastelloy is a registered trademark of Haynes International.
CJ2-Z Series 10, 16 Air Cylinder 10-/1121-/22RoHS How to Order Cushion Clean series 10 11 Relief type Vacuum suction type Nil A Rubber bumper (Standard) Air cushion 10 D L 16 60 A R C J 2 M9BW Z B 21 D L 16 60 R C J 2 M9BW Z B Number of auto switches Nil Built-in magnet Head cover port location Nil S n 2 pcs. 1 pc. n pcs.
Polyurethane Coil Tubing: Series 10-TCU For details, refer to Pneumatic Clean Series catalog. Specifications 10-TCU 10-TCU 10-TCU 10-TCU 0425B-1 0425B-2 0425B-3 0604B-1 0604B-2 0604B-3 0805B-1 10-TCU 10-TCU 10-TCU Model Tubing O.D. (mm) No. of cores 2 cores 3 cores 1 core 2 cores 3 cores 1 core 1 core 4 6 4 8 5 Tubing I.D.
-A-20/40HRSH150-W-20/4025 25 Facility water temperature 32C Ambient temperature 32C 20 20 Cooling capacity [kW] Cooling capacity [kW] 15.7 15.7 15 15 Ambient temperature 43C 10 10 Facility water temperature 40C Ambient temperature 45C 5 5 0 0 5 10 15 20 25 30 35 5 10 15 20 25 30 35 Circulating fluid temperature [C] Circulating fluid temperature [C] HRSH200-A-20/40HRSH200-W-20/4030 30 Ambient
Leakage voltage Particularly when using a resistor in parallel with a switching element and using a C-R element (surge voltage suppressor) to protect the switching element, take note that leakage current will flow through the resistor, C-R element, etc., creating a possible danger that the valve may not turn off. 1.