With cap SR 6.8 8.7 12 18 25 B 6.5 9 12.5 16 21 A MM h M8 x 1.0 M10 x 1.0 M14 x 1.5 M20 x 1.5 M27 x 1.5 B 4 4 6 6 6 C 12 14 19 27 36 MM B M8 x 1.0 M10 x 1.0 M14 x 1.5 M20 x 1.5 M27 x 1.5 C h1 h2 d f RBC08C RBC10C RBC14C RBC20C RBC27C RB08J RB10J RB14J RB20J RB27J RB08S RB10S RB14S RB20S RB27S 6 7.5 10 20 25 12 14 19 27 36 13.9 16.2 21.9 31.2 41.6 6.5 8 11 16 22 23 23 31 40 51 9 11 15 23 32

If the voltage increase ratio (dV/dt) at the zero cross should exceed 40 V/200 sec., it may result in malfunction. 4 min 6 min 10 min 14 min 20 min 30 min 2 min 1 min Max.

port) 3 (Breathing port) 5 x , 14 38 (Piping port) 5 x , 14 38 (Piping port) 3 position closed center/exhaust center/pressure center: VFA3 40-X1 3 4 5 02 03 2 x 4.3 2 x 18 (Mounting hole) (Pilot port) Breathing port 5 x , 38 14 (Piping port) 1766 5 Port Air Operated Valve Series VFA5000 How to Order Port size 02 03 1 4 3 8 Body ported VFA5 1 20 03 Base mounted VFA5 1 44 03 1(P) port location

VS7-8-FG-S AXT510-12 AXT510-21 AXT510-13 AXT510-13 AXT510-13 AXT510-14-2 AXT510-14-2 AXT510-14-2 AXT510-14-1 AXT510-14-1 AXT510-14-1 MY-16N MY-16N MY-14N Description No.

Box 3385 Al-Amir Majed Street, Jeddah-21471, Saudi Arabia TEL: 02-6761574 FAX: 02-6708173 14-21-21

Box 3385 Al-Amir Majed Street, Jeddah-21471, Saudi Arabia TEL: 02-6761574 FAX: 02-6708173 14-21-21

Make a model selection, considering a load according to the graph on pages 8 to 14.

10.5 12 8.5 20 24 20.5 14.5 19.5 16 17.5 14 14.5 18.5 15 9 14 10.5 12 8.5 20 24 20.5 14.5 19.5 16 17.5 14 14.5 18.5 15 9 14 10.5 12 8.5 22 26 22.5 16.5 21.5 18 19.5 16 19.5 23.5 20 14 19 15.5 17 13.5 27 31 27.5 21.5 26.5 23 24.5 21 17.5 21.5 18 12 17 13.5 15 11.5 27.5 31.5 28 22 27 23.5 25 21.5 17.5 21.5 18 12 17 13.5 15 11.5 27.5 31.5 28 22 27 23.5 25 21.5 13.5 15 16.5 13 27.5 29 30.5

It can cause damage or air leakage. 100 8 7 to 9 150 1/8 14 12 to 14 200 1/4 17 22 to 24 200 3/8 21 28 to 30 200 1/2 24 Lock Nut Tightening Torque Caution 1. Suitable screw torque for a hexagon lock nut is shown in the table below. For standard installation, turn 15 to 30 using tool, after fastening by hand. Pay attention not to over torque the product.

PLC: Programmable Logic Controller Refer to pages 14 through 19 for sections related to auto switches.

14 14 17 17 17 17 17 90 90 90 126 126 126 197 197 30 30 30 60 60 80 120 120 177 177 177 227 227 227 285 285 110 110 110 130 130 130 150 150 120 120 120 140 140 140 170 170 30 310 380 450 520 590 45 385 485 585 685 560 650 750 850 Fixed L-type block companion flange Connection part dimensions/ Companion flange Female threaded companion flange Differential pressure indication switch d Differential

Box 3385 Al-Amir Majed Street, Jeddah-21471, Saudi Arabia TEL: 02-6761574 FAX: 02-6708173 14-21-21

12 19 23.5 B 13 15 14 19.5 A 14.5 12.5 19.5 24 B 13.5 15.5 14.5 20 B 7.5 9.5 8.5 14 B 10.5 12.5 11.5 17 B 7 9 8 13.5 20 25 32 40 Note) When setting an auto switch, be sure to check its operation before adjusting.

Tel :03-3502-2740 Fax:03-5251-7240 August 1996, 14(RP)

BA 0 0.3 CA BA 0 0.3 Drawing of view E MM (mm) Bore size Z A NN S Y LB LC LH LT LX LY LZ X 85.5 6 15 15 17 3 8 12 11 28 16.5 4.5 9 1.6 24 16.5 32 24.5 7 M3 x 0.5 M8 x 1.0 57.5 5 T NA NB BA BB CA CB D F GA GB GC H 3 7 83 82 16 10 54 55 M12 x 1.0 M10 x 1.0 21.5 23 5.5 5.5 14 14 2.3 2.3 33 33 25 25 42 42 20.5 20.5 9.5 9.5 M5 x 0.8 M4 x 0.7 18.3 12 17 20 20 14 5 4 8 8 5 5 5 5 11 11 28 28 15

14 16.2 16.2 4 4 MK(2) Note) L, LL and S dimensions of RBL(C)1007/1006 are different from those of RB(C)1007/1006.

Auto Switch Internal Circuit D-C73C Contact protection box CD-P12 Brown Choke coil LED OUT () Brown Weight Resistor Zener diode Reed switch Zener diode (g) OUT ( ) Blue D-C73C D-C80C Auto switch model Blue 14 14 0.5 Lead wire length (m) 53 53 3 D-C80C 83 83 5 Contact protection box Dimensions OUT () Brown Reed switch CD-P11 CD-P12 Lead wire with connector OUT ( ) Blue Indicator light D-C80C

20 25 32 40 Bore size (mm) 20 25 32 40 Z R Y 250 to 400 190 14 129 350 to 500 207 14 146 350 to 600 210 14 146 350 to 800 236 15 191 Note) Dimensions marked with are not required for the one without rear plate. 9-4-8 9 Fine Lock Cylinder with Guide Series MLGC Proper Auto Switch Mounting Position (Detection at stroke end) and Its Mounting Height Hs CL CL1 MLGC CNG Auto switch D-C7/C8,

Auto Switch Internal Circuit D-C73C Contact protection box CD-P12 Brown Choke coil LED OUT () Brown Weight Resistor Zener diode Reed switch Zener diode (g) OUT ( ) Blue D-C73C D-C80C Auto switch model Blue 14 14 0.5 Lead wire length (m) 53 53 3 D-C80C 83 83 5 Contact protection box Dimensions OUT () Brown Reed switch CD-P11 CD-P12 Lead wire with connector OUT ( ) Blue Indicator light D-C80C

Auto Switch Internal Circuit D-C73C Contact protection box CD-P12 Brown Choke coil LED OUT () Brown Weight Resistor Zener diode Reed switch Zener diode (g) OUT ( ) Blue D-C73C D-C80C Auto switch model Blue 14 14 0.5 Lead wire length (m) 53 53 3 D-C80C 83 83 5 Contact protection box Dimensions OUT () Brown Reed switch CD-P11 CD-P12 Lead wire with connector OUT ( ) Blue Indicator light D-C80C