SMC Corporation of America
Elite Part Number Search
Search Results "52-IP8101-034-W-3"

Lead wire length (m) Load voltage Auto switch models Indicator light Type Special function Wiring (output) Electrical entry Applicable bore sizes Applicable loads 0.5 (Nil) 3 (L) 5 (Z) None (N) DC AC 20 to 63 20 to 100 3 wire (NPN equiv.)

3 300 11-LEFG16-S-350 444 357 430 11-LEFG16-S-400 494 407 480 10 4 400 11-LEFG16-S-450 544 457 530 11-LEFG16-S-500 594 507 580 12 5 500 40 11-LEFG25-S 45 64 (102) 3H9 (+0.025 0 ) depth 3 4 x M5 x 0.8 thread depth 8.5 38 50 3.5 3H9 (+0.025 0 ) depth 3 A (Table traveling distance) L 51 (52) 10 10 58 38 48 38.5 (48) 26 24 n x 4.5 Vacuum port Rc1/8 48 120 F D x 120 (= E) B Dimensions [mm] Dimensions

rated voltage Allowable voltage fluctuation Coil insulation type Class B 500 VDC, 10 M or more Insulation resistance Voltage limit 1800 VAC, 1 sec., 3 mA or less Simulation noise: 500 Vp-p (Based on 1 sec. pulse width, 50 10 Hz frequency noise simulation) Noise tolerance Note 3) Fast transient noise: IEC61000-4-4: 1 kV VDW30: 3 W (With 0.5 W power-saving circuit) VDW40: 6.5 W (With 1 W

Power saving circuit is only available in the "Z" type. 3 220 VAC 50/60 Hz [230 VAC 50/60 Hz] 4 How to Order M8 Connector Cable For type W, DC voltage is only available.

Load weight Allowable moment E-MY2H/m3 E-MY2H/M3 E-MY2H/M1 E-MY2H/M2 60 50 60 50 60 50 60 50 40 40 30 30 30 30 q r w et 20 20 20 20 Moment (Nm) Moment (Nm) Moment (Nm) Moment (Nm) 10 10 10 10 MY2H25 MY2H25 MY2H25 MY2H25 5 5 5 5 4 4 MY2H16 4 4 3 3 3 3 MY2H16 MY2H16 2 2 2 2 MY2H16 0.2 1 1 1 100 200 300 400500 1000 1500 1 100 200 300400 500 1000 1500 100 200 300400500 1000 1500 100 200 300400500

Step 2 Determine the filter model and number units based on the results of Step 3 Determining the model and number of units Step 2 Step 3 and .

Theoretical lifting force of vacuum cup diameter 32mm with ZP2V-B06-05 at supply pressure 0.5 MPa Vacuum pressure Theoretical lifting force Horizontal lifting force [N]Safety factor 1/4 [kPa] [N] 1 cup gripping -50 40.2 10 2 cups gripping -67 53.8 13.4 3 cups gripping -73 58.7 14.6 (Calculated by W = P X S, S = r2, r = 32 / 2.

indication (2 color) F59 3 wire (NPN) IC circuit 5V, 12V 24V F5P 3 wire (PNP) J51 100V, 200V 2 wire J59 12V 3 wire (NPN) F59W IC circuit 5V, 12V Diagnostic indication (2 color) Relay PLC 3 wire (PNP) F5PW Grommet Yes J59W 12V 24V 2 wire Water resistant (2 color) F5BA * Lead wire length 0.5m (Example): A53 3m L (Example): A53L 5m Z (Example): A53Z IC circuit 3 wire (NPN) F5NT

Load voltage Auto switch model Lead wire length [m] Pre-wired connector Applicable load DC AC Perpendicular In-line 0.5 (Nil) 1 (M) 3 (L) 5 (Z) Indicator light Type Special function Electrical entry Wiring (Output) M9NV M9N IC circuit 3-wire (NPN) 5 V, 12 V Solid state auto switch 3-wire (PNP) M9PV M9P 2-wire 12 V M9BV M9B 3-wire (NPN) 5 V, 12 V M9NWV M9NW IC circuit 3-wire (PNP) M9PWV M9PW

8 1/4, 3/8, 1/2 3/4 3/4, 1 1 324 333 333 332 335 38 40 38 41 45 53 70 75 90 95 54

81.5 93.5 CB 2 2 2 3 3 3 5 5 5 H 19 26 32 39 44 55 67 85 97 D 7.6 12 16.6 21.6 26.4 33.6 41.6 52.4 65.4 Model 12-CY3R6 12-CY3R10 12-CY3R15 12-CY3R20 12-CY3R25 12-CY3R32 12-CY3R40 12-CY3R50 12-CY3R63 L 34 38 53 62 70 76 90 110 118 W 20 20 25 40 40 50 60 60 70 X 10 15 18 22 28 35 40 50 60 LD 3.5 3.5 4.3 5.4 5.4 7 7 8.6 8.6 WP 9.5 13 16 19 21.5 27 32 41 47 Y 35.5 39.5 54.5 64 72 79 93 113 121

A span adjuster and zero adjuster are provided for the adjustment of the feed back spring.Output current (4-20mADC) realizes remote position detecting (rotary type), Vibration resistance: No resonances 5 to 200Hz, Dust resistance: Conforms to JIS F8007 IP65, Pressure gauge O.D. ø43, Accessories include:  Output restriction w/pilot valve, fork lever joint, compensation spring, w/external scale

sub-plate 1/8 NPTF 1/4 NPTF 3/8 NPTF 01T 02T 03T Symbol (A) 2 N.C. 1 IP65 Option (Y, YZ only) 1 (P) 3 (R) Metal seal Rubber seal W Standard IP65 rated (A) 2 N.O. 2 1 (P) 3 (R) Manual override (A) 2 N.C.

Item Specifications Input type Note1) Step data input type Pulse input type Compatible motor LAT3 series Number of axis per controller Single axis Control method Closed-loop control with encoder feedback signal Power supply voltage: 24 VDC +/-10 Power supply specifications Note 2) Current consumption: 2 A (Maximum 3 A) Note 3) Power consumption: 48 W (Maximum 72 W) Note 3) Positioning operation

115 150 45 167.5 97.5 132.5 185 69.5 L3 87 122 157 52 174.5 104.5 139.5 192 3 stns. x 1 2 stns. x 2 3 stns. x 2 2 stns. + 3 stns. x 2 2 stns. x 1 3 stns. x 3 2 stns. + 3 stns. 2 stns. x 2 + 3 stns. 2 stns. x 2 + 3 stns. x 2 Manifold composition Note) Manifold bases are composed by connecting 2 station and 3 station bases.

Terminal q DC (+) w N.C e DC () r IN (1 to 5 V) e w q Power supply/Output connection cable (Accessory) Power supply/Output connector (8P) Pin no. 7 Green 8 Yellow 6 Red 5 Gray 4 White 3 Black 2 Blue 1 Brown i u y t r e w q Pin no.

8 8 14 23 39 47 47 48 39 65 78 86 42 46 56 52 56 66 63 80 90 3 8 1 2 32.5 118 (136) 17.5 23 39 45.5 3 4 VXD2150 VXD2260 1 VXD2152 VXD2262 36.5 133 (150) 20 25.5 41.5 49.5 ( ): N.O. 17-3-40 9 Series VXD21/22/23 Pilot Operated 2 Port Solenoid Valve For Air, Gas, Water and Oil The VX series will be revised shortly.

SY114/SY124, SY114A/SY124A only. 2.1-6 Series SY100 Construction SY114, SY114A (A) 2 3 (R) 1 (P) q y e r w i SY SYJ VK VZ VT VT VP A R P o u t !0 !1 VG VP VQ VQZ Part No.