This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYL, COMPACT, CLN RM, ACTUATOR, CQ2 COMPACT CYLINDER, M5, 40MM CQ2 CLEAN-ROOM, 1.10231 lb

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYL, COMPACT, CLEAN ROOM, ACTUATOR, CQ2 COMPACT CYLINDER, P5, 63MM CQ2 CLEAN-ROOM, 2.09439 lb

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYL, COMPACT, CLEAN ROOM, ACTUATOR, CQ2 COMPACT CYLINDER, F5, 12MM CQ2 CLEAN-ROOM, .33069 lb, SeriesModelActionNoteCQ2StandardCQ2Double acting, Single rodExcept with rubber bumper

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, 25MM CQ2 CLEAN-ROOM, ACTUATOR, CQ2 COMPACT CYLINDER, I5, 25MM CQ2 CLEAN-ROOM, 0.63033 lb

Magnet: D (Built-in Magnet), Mounting Direction: B (Lateral Mounting), Bore Size: 6mm, Stroke: 6mm, Action: D (Double Acting), Rod End Thread: Rod End Female Thread, Auto Switch: M9N--Solid State, Gen. Purpose, 3 Wire NPN, Horizontal, 0.5m, Lead Wire or Prewired Connector: L (3m), Number: S (1 pc.)

This is a legacy product. Please contact us for the latest version.sales@ocaire.com

Clean Room: 10 (Relief Type), Magnet: D (Built-in), Mounting Direction: B (Lateral Mounting), Bore: 6mm, Stroke: 15mm, Rod End Thread: Rod End Female Thread, Auto Switch: F8N--Solid State, Gen. Purpose, 3 Wire NPN, Horizontal, Lead Wire or Prewired Connector: L (3m)

Clean Room: 10 (Relief Type), Magnet: D (Built-in), Mounting Direction: B (Lateral Mounting), Bore: 6mm, Stroke: 10mm, Rod End Thread: Rod End Female Thread, Auto Switch: F8B--Solid State, Gen. Purpose, 2 Wire, Horizontal

Clean Room: 10 (Relief Type), Magnet: D (Built-in), Mounting Direction: B (Lateral Mounting), Bore: 6mm, Stroke: 4mm, Rod End Thread: Rod End Female Thread, Auto Switch: M9P--Solid State, Gen. Purpose, 3 Wire PNP, Horizontal, Lead Wire or Prewired Connector: MAPC (1.0m Cord Length, M8-3 Pin Connector), Number: S (1 pc.)

Clean Room: 10 (Relief Type), Magnet: D (Built-in), Mounting Direction: B (Lateral Mounting), Bore: 6mm, Stroke: 15mm, Rod End Thread: M (Rod End Male Thread), Auto Switch: F8B--Solid State, Gen. Purpose, 2 Wire, Horizontal, Lead Wire or Prewired Connector: L (3m)

Clean Room: 10 (Relief Type), Magnet: D (Built-in), Mounting Direction: B (Lateral Mounting), Bore: 6mm, Stroke: 8mm, Rod End Thread: Rod End Female Thread, Auto Switch: F8N--Solid State, Gen. Purpose, 3 Wire NPN, Horizontal

Clean Room: 10 (Relief Type), Magnet: D (Built-in), Mounting Direction: B (Lateral Mounting), Bore: 6mm, Stroke: 4mm, Rod End Thread: Rod End Female Thread, Auto Switch: M9PW--Solid State, 2-color Indication, 3 Wire PNP, Horizontal, Lead Wire or Prewired Connector: L (3m), Number: S (1 pc.)

Clean Room: Relief Type, Magnet: Built-in, Mounting Direction: Lateral Mounting, Bore: 6mm, Stroke: 15mm, Rod End Thread: Rod End Female Thread, Auto Switch: F8N--Solid State, Gen. Purpose, 3 Wire NPN, Horizontal, Lead Wire or Prewired Connector: 3m, Number: -

Clean Room: Relief Type, Magnet: Built-in, Mounting Direction: Lateral Mounting, Bore: 6mm, Stroke: 10mm, Rod End Thread: Rod End Female Thread, Auto Switch: F8B--Solid State, Gen. Purpose, 2 Wire, Horizontal, Lead Wire or Prewired Connector: -, Number: -

Clean Room: Relief Type, Magnet: Built-in, Mounting Direction: Lateral Mounting, Bore: 6mm, Stroke: 4mm, Rod End Thread: Rod End Female Thread, Auto Switch: M9P--Solid State, Gen. Purpose, 3 Wire PNP, Horizontal, Lead Wire or Prewired Connector: 1.0m Cord Length, M8-3 Pin Connector, Number: 1 pc.

Clean Room: Relief Type, Magnet: Built-in, Mounting Direction: Lateral Mounting, Bore: 6mm, Stroke: 15mm, Rod End Thread: Rod End Male Thread, Auto Switch: F8B--Solid State, Gen. Purpose, 2 Wire, Horizontal, Lead Wire or Prewired Connector: 3m, Number: -

Clean Room: Relief Type, Magnet: Built-in, Mounting Direction: Lateral Mounting, Bore: 6mm, Stroke: 8mm, Rod End Thread: Rod End Female Thread, Auto Switch: F8N--Solid State, Gen. Purpose, 3 Wire NPN, Horizontal, Lead Wire or Prewired Connector: -, Number: -

Clean Room: Relief Type, Magnet: Built-in, Mounting Direction: Lateral Mounting, Bore: 6mm, Stroke: 4mm, Rod End Thread: Rod End Female Thread, Auto Switch: M9PW--Solid State, 2-color Indication, 3 Wire PNP, Horizontal, Lead Wire or Prewired Connector: 3m, Number: 1 pc.

Magnet: Built-in Magnet, Mounting Direction: Lateral Mounting, Bore Size: 6mm, Stroke: 6mm, Action: Double Acting, Rod End Thread: Rod End Female Thread, Auto Switch: M9N--Solid State, Gen. Purpose, 3 Wire NPN, Horizontal, 0.5m, Lead Wire or Prewired Connector: 3m, Number: 1 pc.

The CLS series cylinder with lock is ideal for applications requiring intermediate and emergency stop and drop prevention. The compact lock unit is lightweight and saves space. A switch is optional on the brake cylinder so the operating state of the lock unit (brake piston) can be detected using the switch signal. By separating the lock mechanism and the brake cylinder, SMC has minimized