(Becomes close to the trapezoidal acceleration as the setting value reaches 0) Acceleration and deceleration ratio 10 10 10 10 to 100 EQFS251 to 50 EQFS321 to 70 EQFS401 to 70 Torque when held *2 50 70 70 Sets the torque when stopped after the positioning operation. (Unit: %) H 140 80 80 Sets the position loop P constant.

High rigidity slider type / LEJS series 2.1 Specification LEJS Ball screw drive Model LEJS40 LEJS63 Stroke [mm] Note1) 200,300,400,500,600,700 800,900,1000,1200 300,400,500,600,700,800 900,1000,1200,1500 Work load [kg] Note2) Horizontal 15 30 55 30 45 85 Vertical 3 5 10 6 10 20 Up to 500 1800 1200 600 1800 1200 600 501 to 600 1580 1050 520 1800 1200 600 601 to 700 1170 780 390 1800 1200 600

4.7 8.0 12 18 29 48 [kPa] -55 2.7 4.3 7.3 11 17 27 44 -50 2.5 3.9 6.7 10 15 24 40 -45 2.2 3.5 6.0 9.0 14 22 36 -40 2.0 3.1 5.3 8.0 12 19 32 -10No.

4.7 8.0 12 18 29 48 [kPa] -55 2.7 4.3 7.3 11 17 27 44 -50 2.5 3.9 6.7 10 15 24 40 -45 2.2 3.5 6.0 9.0 14 22 36 -40 2.0 3.1 5.3 8.0 12 19 32 -10No.

4.7 8.0 12 18 29 48 [kPa] -55 2.7 4.3 7.3 11 17 27 44 -50 2.5 3.9 6.7 10 15 24 40 -45 2.2 3.5 6.0 9.0 14 22 36 -40 2.0 3.1 5.3 8.0 12 19 32 -10No.

Model/Valve Specifications Av x 10-6m2 Cv converted C [dm 3/(sbar)] b Cv Water, Oil, Steam Air Flow characteristics Maximum operating pressure differential (MPa) Min. operating pressure differential (MPa) 10 10 15 10 15 20 Connection Orifice Max. system pressure (MPa) Weight (g) Model Water AC DC AC DC AC DC AC Air Oil Steam size (mm) Thread VXP2130-02 0.7 0.7 1.0 0.7 1.0 1.0 1 4 740 500

A 1 2 150 165 42.7 76.3 45 65 40 60 35 40 80 80 ALBA90-10 ALBA90-20 1.17-24

Hexagon width across flats 24 25 G Width across flats 37 45 45 4-M4 x 0.7 4-M4 x 0.7 E 10 10 G Width across flats 37 F F E Y Y 8 8 34 34 C C A A B D B D Dimensions Dimensions (mm) (mm) Model Model B A B C D E F G Y A C D E F G Y ZPT63HB-A16 ZPT63HB-B8 63 65.1 45.5 67.6 31.5 43 73 21.5 M8 x 1.25 ZPT80HB-A16 -B10 80 83 58.4 85.1 37 48.5 78.5 27.5 M10 x 1.5 63 65.1 45.5 67.6 31.5 43 21.5 -B12

Operation Instructions . 45 .. Outline of operation command . 45 .. Positioning operation . 45 .. Pushing operation . 48 .. Reset . 51 . Operation Examples . 52 .. Positioning operation . 52 .. Pushing operation . 53 Operation Mechanism.54 1 - . Positioning operation . 54 . Pushing operation . 54 . Return to the origin . 56 .

11) (0.5) 10 5 5 2-1 (Bleed port) 10 10 7 7 2-1 (Bleed port) M3 x 0.5 (Piping port) 28 M5 x 0.8 (Piping port) 3 position closed center/exhaust center/pressure center SYJA3 20-M3(-F) 3 position closed center/exhaust center/pressure center SYJA3 40-M5 3 4 5 3 4 5 7.1 9 10 2-M3 x 0.5 (Pilot port) 1.8 10 4 A B 1.5 7 8.2 19 2-M3 x 0.5 (Pilot port) (For mounting) 2-3.2 22 3 49 2.5 (For mounting

The amount of moisture is 3.0 g/m3. 10.

80A Steel tube 80A Steel tube Piping A Piping A 30 Series VXF2/VXFA2 RoHS Controller Dedicated For Operation/Series VXFC How to Order Controller D VXFC 06 Voltage Number of output points 06 10 D D-6 A 24 to 48 VDC 6 output points 12 VDC 10 output points 85 to 220 VAC Specifications 06 10 VXFC D 06 10 VXFC A 06 10 VXFC D-6 85 to 220 VAC 24 to 48 VDC Model Input voltage 12 VDC Output voltage

Part No. of ejector valve for ZYY3000/ZYX3000 Number of ejectors 1 to 10 Ejector mounting position U D U side D side [Example: When individual wiring type model 45 for SY3000 is selected] ZZY Y3-45-04D-C6J1U 1SET SY3000 manifold model Ejector valve number Note 1) The combined total of solenoid valve and ejector valve stations is a maximum of 20 stations.

Structural Drawing, Option and Replacement Parts 10 6. Bowl Assembly Specifications 11-18 7. Assembly of Optional Parts 19 8. Operation and Adjustment 20-21 9. Trouble Shooting 22 10. How to Replace the Components 23-28 10-1. Bowl Assembly Replacement 23-25 10-2. Element Replacement 26-28 11. Disassembly Drawing 29 12.