KN-R02-100 KN-R02-150 KN-R02-200 KN-R02-250 VMG1-R02-300 VMG1-R02-350 VMG1-R02-400 KNH-R02-100 KNH-R02-150 KNH-R02-200 KNS-R02-075-4 KNS-R02-090-8 KNS-R02-100-4 KNS-R02-110-8 VMG1-06-150-300 VMG1-06-200-300 VMG1-06-150-600 VMG1-06-200-600 VMG1-06-150-100 VMG1-06-200-100 VMG1-06-150-150 VMG1-06-200-150 Nozzle size 1 1.5 2 2.5 3 3.5 4 1 1.5 2 0.75 x 4 0.9 x 8 1 x 4 1.1 x 8 1.5 2 1.5 2 1.5 2
knuckle joint Press-fit spring pin 3 x 22 L 10 +0.022 H8 0 13 Press-fit spring pin 3 x 22 L Shaft: 10 Hole: 10 13 0.040 d9 0.076 +0.022 H8 0 24 24 C7 C7 30 +0.5 +0.2 12 0.1 0.3 12 41.2 26 24 18 36 36 D48 48 Please contact SMC for details of the CKGA32 series.
fluctuation 10 to +10% of rated voltage* a a 12(P1) PA 2(A) 3(R) 1(P) 2(A) 3(R) 1(P) 2(A) 3(R) 1(P) 100 V 0.78 (With indicator light: 0.81) 110 V 0.86 (With indicator light: 0.89) 200 V 1.18 (With indicator light: 1.22) 220 V 1.30 (With indicator light: 1.34) G, L, M Apparent power [VA] AC 100 V 0.78 (With indicator light: 0.87) 110 V 0.86 (With indicator light: 0.97) 200 V 1.15 (With indicator
Controller USB cable Communication 120.3 120.3 mm mm 200 200 mm/s mm/s (type A to mini-B) cable 100 500 100 500 1 1 200 1000 200 1000 2 2 50 200 50 200 3 3 CN3 PC (PC is prepared by the user.) 20 - 4.4 CN4: Counter connector (option) Connect the controller to the Multi-counter (CEU5) using the counter cable (LATH3-). Refer to section 6.2 Counter plug wiring (P.24).
0.07 10 0.07 5 0.03 5 0.03 0 0.00 0 0.00 0 20 40 60 80 100 Flow rate (slpm, N2) 0 40 80 120 160 200 240 280 320 Flow rate (slpm, N2) ) If connection size differs, flow characteristics also differ.
Note 7) Refer to 10 in Design and Selection on the back of page 2, if the valve is to be energized continuously for extended periods of time. 14 Series LVM20/200 Construction: Base Mounted LVM20R3 LVM20R4 !0 !0 i i o y t o y t u u r r !1 !1 e q e q w !2 w !2 LVM205R !0 i o y t Description No.
W or less 20 VA or less 10 W or less 20 VA or less 10 W or less 20 VA or less 10 W or less Between case and AC line: 1500 VAC for 1 min.
Normal output Reversed output -100No.PF-OMA1011-A Specifications Model PFG20# series PF2A5 PF3W5 PF2D5 Applicable flow sensor 10 50 11 21 51 04 20 40 11 25 04 20 40 Rated flow range 1 to 10 5 to 50 10 to 100 20 to 200 50 to 500 0.5 to 4 2 to 16 5 to 40 10 to 100 50 to 250 0.4 to 4 1.8 to 20 4 to 40 L/min L/min L/min L/min L/min L/min L/min L/min L/min L/min L/min L/min L/min 0.35 to 1.7 to
Note 10) : For thread type: NPT only.
20 25 30 50 100 150 200 12 (10 x 2) 0.13 0.10 0.08 0.06 0.04 [kg] Bore size Stroke [mm] 10 20 25 30 50 100 150 200 12 (10 x 2) 0.9 0.7 0.5 0.4 0.2 16 (12 x 2) 0.14 0.11 0.09 0.07 0.04 16 (12 x 2) 0.9 0.7 0.6 0.4 0.2 20 (16 x 2) 0.27 0.22 0.16 0.10 0.07 20 (16 x 2) 1.3 1.0 0.8 0.5 0.3 25 (20 x 2) 0.54 0.45 0.34 0.21 0.15 25 (20 x 2) 2.3 1.9 1.4 0.9 0.6 32 (25 x 2)
A 180/200 W 50/60 Hz 220 W 0.01 m (99.9% filtration efficiency) Particles of 0.3 m or more: 3.5 particles/L [ANR] or less Heater operation, PID control Singlephase 200 VAC (50/60 Hz) 2.1 A 5 A Singlephase 230 VAC (50/60 Hz) 2.1 A 5 A Singlephase 100 VAC (50/60 Hz) 9.4 A 15 A Singlephase 200 VAC (50/60 Hz) 4.8 A 10 A Singlephase 230 VAC (50/60 Hz) 4.8 A 10 A Power supply Note 4) Operating
Standard part number 10 Note) Contact SMC if equipped with pressure gauge.
Description IR1000 IR1010 IR1020 IR2000 IR2010 IR2020/2120 IR3000 IR3010 IR3020/3120 P362030-201 Bracket P36201023 P36202028 Pressure gauge2 G33-4-01 G43-4-01 G33-2-01 G33-10-01 G43-2-01 G43-10-01 G43-2-01 G43-4-01 G43-10-01 1 A bracket and two mounting screws (M5 x 35) To mount the bracket, remove two body screws (M5 x 30) on the name plate on the opposite side and replace the attached two
ZP3(10/13/16) UM: ZP3(10/13/16) B: ZP3(10/13/16) UM: ZP3(10/13/16) B: ZP3(10/13/16) UM: ZP3(10/13/16) B: ZP3(10/13/16) UM: ZP3(10/13/16) B: ZP3(10/13/16) UM: ZP3(10/13/16) B: ZP3-T (10/13/16) UM:-A5 ZP3-T (10/13/16) B:-A5 ZP3-T (10/13/16) UM:-B5 ZP3-T (10/13/16) B:-B5 ZP3-T (10/13/16) UM:-A12-@ ZP3-T (10/13/16) B:-A12-@ ZP3-T (10/13/16) UM:-A12-04 ZP3-T (10/13/16) B:-A12-04 ZP3-T (10/13/16
).1A or less 24 VDC 10).1A or less 24 VDC: lmA or less 100 VAC: 1mA or less 200 VAC: 1.5mA or less Indlcetor lamp.
P211070-10 P211090-10 P211060-10 P211080-10 P211010-10 P211070-10 P211090-10 P211060-10 P211080-10 P211010-10 CDRB1BW50 Series CRB1 Series CRB2 Single/Double type CDRB1BW63, 80, 100 Solid state switch for size 10 and 15 requires no switch block, therefore the unit part no. will be P611070-13.
Series SY3000/5000/7000 Dimensions 2-One-touch fitting (ports P, R) Applicable tube O.D.: 10 SS5Y5-60Stations U (Station n) (Station 1) 2 3 4 5 6 7 8 9 10 Stations 51.9 (4.9) (Light/surge voltage suppressor) 43.8 (5.5) L1 123 135.5 148 160.5 185.5 198 210.5 235.5 248 L2 112.5 125 137.5 150 175 187.5 200 225 237.5 L3 88 104 120 136 152 168 184 200 216 L4 17.5 15.5 14 12 16.5 15 13 17.5
10 2 10 15 20 CXT 32 40 5 15 10 5 1 10 10 20 (mm) D-F7W D-J79W D-F7BAL D-F7NT D-F79F Auto switch model D-A7 D-A8 D-A73C D-A80C D-A7H D-A80H D-F7 D-J79 D-F7V D-J79C D-F7WV D-F7BAVL D-A79W Application No. of auto switches mounted 2 5 10 15 15 20 20 CXT 32 40 1 5 5 10 15 15 20 Other than the applicable auto switches listed in How to Order, the following auto switches can be mounted.
200 300 300 200 Usable range 100 100 Usable range 20 30 40 50 50 40 30 20 10 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 10 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 Distance from cylinder shaft center: L0 (cm) Distance from cylinder shaft center: L0 (cm) Note: 1N = 0.2248lbf 1kg = 2.2046lb 1in = 25.4mm 1in = 2.54cm 100 80 REA63 REA50 50 40 30 REA40 REA32
6 1000 20 5 100 30 4 10 50 6 1000 5 5 100 15 4 10 30 6 1000 20 5 100 50 4 10 60 6 1000 10 5 100 40 4 10 50 6 1000 50 5 100 80 4 10 100 LEFS16 500 500 LEFS25 900 500 Please aspirate it from the port on both sides when aspirating 50 /min(ANR).