Type of Actuation: 1 (2 Position Single), Manifold Type: 20 (Body Ported), Pilot: Internal Pilot, Specifications: T (Power Saver), Voltage: 6 (12VDC), Electrical Entry: M (M Plug Connector w/Lead Wire 0.3m), Lead Wire Length: None, Surge Suppressor: Z (Light & Surge Suppressor), Manual Override: Non-locking Push Style, A, B Port Size: N11 (3/8" One-touch Fitting), Thread: T (NPTF)
Body Size: 50, Thread: N (NPT), Port: 06 (3/4), Option: CG (C + G), Attachment: T (T-spacer), Semi-Standard 1: Standard, Semi-Standard 2: RZ (R + Z)
Body Size: 40, Thread: Rc, Port: 04 (1/2), Option: CG (C + G), Attachment: T (T Spacer), Semi-Standard 1: Standard, Semi-Standard 2: Standard
Body Size: 60, Thread: Rc, Port: 10 (1), Option: Standard, Attachment: T (T Spacer), Semi-Standard 1: 8 (Metal Bowl w/Level Gauge), Semi-Standard 2: Standard
Body Size: 60, Thread: Rc, Port: 10 (1), Option: G (Round Pressure Gauge w/Limit Indicator), Attachment: T (T Spacer), Semi-Standard 1: 3 (Lubricator w/Drain Cock), Semi-Standard 2: Standard
Body Size: 20, Thread: Rc (Rc: for Sizes 20, 25, 30, 40; M5: for Size 10), Port Size: 01 (1/8), Option: CG (C + G), Attachment: T (T-Interface), Semi-Standard 1: 2 (Metal Bowl), Semi-Standard 2: R (Flow Direction: Right to Left)
Body Size: 50, Thread: Rc, Port: 06 (3/4), Option: D [Float Type Auto Drain (N.O.)], Attachment: T (T Spacer), Semi-Standard 1: Standard, Semi-Standard 2: Standard
Body Size: 20, Thread: Rc (Rc: for Sizes 20, 25, 30, 40; M5: for Size 10), Port Size: 02 (1/4), Option: Standard, Attachment: T (T-Interface), Semi-Standard 1: Standard, Semi-Standard 2: R (Flow Direction: Right to Left)
Body Size: 40, Thread: Rc: Size 20, 25, 30, 40; M5: Size 10, Port Size: 03 (3/8), Option: DM (D + M), Attachment: T (T-Interface), Semi-Standard 1: Standard, Semi-Standard 2: Standard
Body Size: 50, Thread: N (NPT), Port: 10 (1), Option: C [Float Type Auto Drain (N.C.)], Attachment: T (T Spacer), Semi-Standard 1: Standard, Semi-Standard 2: Z (Name Plate, Caution Plate for Bowl, and Pressure Gauge: psi, °F)
(T-branch, for DeviceNetâ„¢ or CC-LInk)
Function: 3 (3 Position Closed Center), Body Option: 20 (Body Ported/Individual Pilot EXH), Pilot: Internal Pilot, Voltage: 5 (24VDC), Lead Wire: T (Conduit Terminal), Surge Suppressor: Z (Light & Surge Suppressor), Manual Override: Non-locking Push Style (Flush), Piping: Side, Port Size: 02 (Base Mounted w/Sub-plate 1/4, Body Ported 1/4), Thread: T (NPTF)
Body Type: T (Body Ported), Valve Option: Standard Type, Pressure Specifications: K (High-Pressure Type (1MPa), Semi-Standard), Rated Voltage: 5 (24 VDC), Electrical Entry: G (300mm Lead Wire), Light_Surge Voltage Suppressor: S (with Surge Voltage Suppressor, Grommet Type Only), Port Size: 02 [1/4 (8A)], Thread Type: T (NPTF)
Stations: 12 Stations (Note: 2 Stations are Required for Terminal Box Mounting), Port Size: B (Bottom Ported Rc1/4), Thread: T (NPTF), Kit Name: T (Terminal Box), Box Mounting Position: 0 (U Side Mounting)
Body Size: 40, Thread: Rc, Port: 06 (3/4), Option: Standard, Attachment: T (T spacer), Semi-Standard 1: 2 (Metal Bowl), Semi-Standard 2: Standard
Body Size: 40, Thread: Rc, Port: 04 (1/2), Option: DG (D + G), Attachment: T (T-spacer), Semi-Standard 1: Standard, Semi-Standard 2: R (Flow Direction: Right->Left)
), Thread: T (NPTF), Option: F2 (Side Bracket)
Stations: 4 Stations, AB Port: 03R (3/8, Right), Thread: T (NPTF), Control: None, PR Port: 06B (3/4, Both Sides), PR Thread: T (NPTF)
Override: Non-locking Push Type, A,B Port Size: None, Mounting Option: K [Round head combination screw (Falling-out prevention type)], Wiring Specification: WO (w/o M12 Connector Cable), Port Location: Side Ported, Sub-plate Thread: T (NPTF)
Rated Vacuum Range: -101 to 0 kPa, Output Specification: T (PNP Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: Unit Selection Function, Piping Specification: 01 (R 1/8), Connector Type: S (M12 Connector Type), Bracket: None, Operation Manual: T (w/o Operation Manual, Calibration Certificate)