This is a legacy product. Please contact us for the latest version.sales@ocaire.com VVX* MANIFOLD VX SERIES. MFLD BASE, VX3300 SERIES. VALVE. VVX* BASE MT 1/4. 1.76369 lb. PJ.
The SV series employs a multi-connector instead of the conventional lead wires for internal manifold wiring. By connecting each block with a connector, changes to manifold stations are greatly simplified. Cassette base type manifolds offer the ultimate in flexibility. Manifold sections can be added using a simple release mechanism. Conventional tie-rod base type manifolds are also available
The SV series employs a multi-connector instead of the conventional lead wires for internal manifold wiring. By connecting each block with a connector, changes to manifold stations are greatly simplified. Cassette base type manifolds offer the ultimate in flexibility. Manifold sections can be added using a simple release mechanism. Conventional tie-rod base type manifolds are also available
VQ valves are ideal for applications requiring high speed, frequent operation, stable response time and long service life. Innovative mounting methods allow valves to be changed without entirely disassembling the manifold. Built-in one-touch fittings save piping time and labor. Fluid: air/inert gas, Operating pressure range: 0.1 - 0.7MPa (high pressure type 0.8MPa), Effective area mm 2
This is a legacy product. Please contact us for the latest version.sales@ocaire.com SS5Y5 MANIFOLD SY5000. MFLD, BODY PT, SY5000 SERIES. VALVE. SS5Y5 NO SIZE RATING. .81377 lb. 2K.
Part Number Description: MFLD ASSY 5-STA Product Line: V Product Line Description: VALVE Family Code: 355 Family Description: SS5Y7 MANIFOLD SY7000 Class Code: PK Part Code: 2 Reference Code: G PDF Documentation: Datasheet Click here to report information errorImage shown may not match exact part number
The VQC series has five standard wiring packages bringing a world of ease to wiring and maintenance work, while the protective enclosures of three of them conform to IP67 standards for protection from dust and moisture. The use of multi-pin connectors to replace wiring inside manifold blocks provides flexibility when adding stations or changing manifold configuration. The VQC series
4/5 PORT SOLENOID VALVE. MANIFOLD ASSY.
4/5 PORT SOLENOID VALVE. SS5Y manifold. 443 lb. VVD.
This is a legacy product. Please contact us for the latest version.sales@ocaire.com
The SV series employs a multi-connector instead of the conventional lead wires for internal manifold wiring. By connecting each block with a connector, changes to manifold stations are greatly simplified. Cassette base type manifolds offer the ultimate in flexibility. Manifold sections can be added using a simple release mechanism. Conventional tie-rod base type manifolds are also available
DUST COLLECTOR VALVE. PILOT VALVE ASSEMBLY. 1.41800 lb. O16.
4/5 PORT SOLENOID VALVE. SS5Y manifold. 0.66600 lb. VVD.
This is a legacy product. Please contact us for the latest version.sales@ocaire.com VVX* MANIFOLD VX SERIES. MFLD BASE, VX2300 SERIES. VALVE. VVX* BASE MT 1/4. 0.88184 lb. PJ.
Series SY offers major advances in valve performance for cost-effective solutions to your requirements. The series offers high flow with low power consumption in a compact design. The SY is available in body ported or base mounted styles and can be used individually or manifold mounted.Fluid: air, Cv factor: 0.008 standard style; 0.012 large flow capacity style, Coil rated voltage: 3, 5,
Part Number Description: MFLD ASSY 5-STA Product Line: V Product Line Description: VALVE Family Code: 355 Family Description: SS5Y7 MANIFOLD SY7000 Class Code: WK Part Code: 2 Reference Code: G PDF Documentation: Datasheet Click here to report information errorImage shown may not match exact part number
VQ valves are ideal for applications requiring high speed, frequent operation, stable response time and long service life. Innovative mounting methods allow valves to be changed without entirely disassembling the manifold. Built-in one-touch fittings save piping time and labor. Fluid: air/inert gas, Operating pressure range: 0.1MPa - 0.7MPa (high pressure style 0.8MPa), Effective area mm
Membrane air dryer series IDG is available in a single unit or combination unit style. IDG/M models combine a mist separator and micro mist separator with a single unit. IDG/V models combine a regulator with the IDG/M model. Options available include one-touch fitting exhaust of purge air. If purged air is not exhausted around membrane air dryer, air is exhausted with tubing away from its
The VZM series is a 5 port mechanical valve. It is compact in design with a large flow capacity (VZM400 Cv 0.55, VZM500 Cv 0.6). The VZM is available in a metal or rubber spool style, with a variety of actuator choices and optional external pilot.Fluid: air, inert gas, Operating pressure: 0.15 to 0.7MPa, Ambient and fluid temp: -5 to 60C (no freezing), Effective area (Cv): 0.6, Port size
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, DIGITAL FLOW SW, INTEG SENSOR, INSTRUMENTATION, IF/PFA FLOW SWITCH, CX, IF/PFA 1/8 INCH ALL OTHERS, .85800 lb, ModelMeasured fluidFlow rate measurement rangeSet flow rate rangeRated flow rangeMinimum set unitAccumulated pulse flow rate exchange value (Pulse width: 50 ms)Note 1, 2)Display unitsOperating