also on the sensor., Fast response: either 50 ms, 0.5s, 1, or 2s can be chosen., Easy connection and removal of wiring., 2-Color Digital Flow Switch for Air, DIGITAL FLOW SWITCH, F29, 135 lb
Series: VQ2000, IN Port Size: C8 (One-touch Fitting for ø8), OUT Port Size: C8 (One-touch Fitting for ø8), Option: F (Bracket)
Series: VQ2000, IN Port Size: C8 (One-touch Fitting for ø8), OUT Port Size: C8 (One-touch Fitting for ø8)
Series: VQ2000, IN Port Size: C8 (One-touch Fitting for ø8), OUT Port Size: C8 (One-touch Fitting for ø8), Option: D [DIN Rail Mounting Style (for Manifold)]
Series: VQ2000, IN Port Size: C8 (One-touch Fitting for ø8), OUT Port Size: C8 (One-touch Fitting for ø8), Option: F (Bracket)
Flow Rate Range: 11 [2 to 100 (50 for CO2) â„“/min], Flow Adjustment Valve: S (Yes), Port Size: 02 (Rc1/4), Piping Entry Direction: Straight, Output Specification: 1 [Analog Output (1 to 5 V)], Instruction Manual: With Instruction Manual, Calibration Certificate: A (w/Calibration Certificate), Connector: Lead Wire w/Connector (2 m), Option: S (Bracket for w/Flow Adjustment Valve)
Structure: IP40, Lead Wire: With lead wire with connector (2 m), Handling Instructions: With Instruction Manual (Japanese and English), Calibration Certificate included: With Calibration Certificate, Flow rate control valve: Available, Custom-made Specifications: None, Rating Flow Range(L/min): 2 to 100 (50), Accessory: None, Option: Bracket (for the one with flow rate control valve), Analog
Flow Rate Range: 25 [0.5 to 25 (25 for CO2) ℓ/min], Flow Adjustment Valve: Yes, Port Size: C8 [ø8 (5/16") One-touch Fitting], Piping Entry Direction: Straight, Output Specification: E [1 PNP Outputs + Analog (1 to 5 V)], Unit Specification: Unit Switching Function, Instruction Manual: None, Calibration Certificate: None, Connector: w/o Lead Wire w/Connector, Option: Panel Mount Adapter for
Flow Rate Range: 25 [0.5 to 25 (25 for CO2) ℓ/min], Flow Adjustment Valve: Yes, Port Size: C8 [ø8 (5/16") One-touch Fitting], Piping Entry Direction: Straight, Output Specification: D [1 NPN Outputs + Analog (4 to 20 mA)], Unit Specification: Unit Switching Function, Instruction Manual: None, Calibration Certificate: None, Connector: W [Lead Wire w/Connector (2m) + Rubber Cover], Option:
Flow Rate Range: 50 [1 to 50 (25 for CO2) ℓ/min], Flow Adjustment Valve: Yes, Port Size: C8 [ø8 (5/16") One-touch Fitting], Piping Entry Direction: Straight, Output Specification: E [1 PNP Outputs + Analog (1 to 5 V)], Unit Specification: Unit Switching Function, Instruction Manual: None, Calibration Certificate: None, Connector: w/o Lead Wire w/Connector, Option: -
Flow Rate Range: 25 [0.5 to 25 (25 for CO2) ℓ/min], Flow Adjustment Valve: Yes, Port Size: C8 [ø8 (5/16") One-touch Fitting], Piping Entry Direction: Straight, Output Specification: E [1 PNP Outputs + Analog (1 to 5 V)], Unit Specification: Unit Switching Function, Instruction Manual: None, Calibration Certificate: None, Connector: w/o Lead Wire w/Connector, Option: -
Flow Rate Range: 50 [1 to 50 (25 for CO2) ℓ/min], Flow Adjustment Valve: Yes, Port Size: C8 [ø8 (5/16") One-touch Fitting], Piping Entry Direction: Straight, Output Specification: F [1 PNP Outputs + Analog (4 to 20 mA)], Unit Specification: Unit Switching Function, Instruction Manual: None, Calibration Certificate: None, Connector: w/o Lead Wire w/Connector, Option: -
Flow Rate Range: 50 [1 to 50 (25 for CO2) ℓ/min], Flow Adjustment Valve: Yes, Port Size: C8 [ø8 (5/16") One-touch Fitting], Piping Entry Direction: Straight, Output Specification: E [1 PNP Outputs + Analog (1 to 5 V)], Unit Specification: Unit Switching Function, Instruction Manual: None, Calibration Certificate: None, Connector: w/o Lead Wire w/Connector, Option: Bracket for w/Flow Adjustment
[Separate Type Connector Connection] Separated sensor, Output Method: Analog, Analog Output Specification: Voltage, Pipe Port Type: [One-Touch Couplings] One-Touch Couplings (Straight), Plumbing Thread Type: -, Plumbing Thread Nominal: -, Pressure Resistance(MPa): 1, Flow Rate Type: Standard, Operating Temperature Range(°C): -10~60, Operating Humidity Range(%): 35~85, Number of Inputs: 2,
Flow Rate Range: 11 [2 to 100 (50 for CO2) â„“/min], Flow Adjustment Valve: None, Port Size: ø8 (5/16") one-touch fitting, Piping Entry Direction: Straight, Output Specification: 1 [Analog Output (1 to 5 V)], Instruction Manual: None, Calibration Certificate: None, Connector: w/o Lead Wire w/Connector, Option: -
Flow Rate Range: 25 [0.5 to 25 (12.5 for CO2) â„“/min], Flow Adjustment Valve: None, Port Size: ø8 (5/16") one-touch fitting, Piping Entry Direction: Straight, Output Specification: 1 [Analog Output (1 to 5 V)], Instruction Manual: None, Calibration Certificate: None, Connector: w/o Lead Wire w/Connector, Option: -
The PFM is available in four maximum flow rate options 10, 25, 50 and 100 /min, and is suitable for use with air, nitrogen, argon or carbon dioxide. 2-color display flow switch., Sensor and monitor separation, which allows remote monitors' centralization., Integrated flow adjustment valve as an option, reducing piping and saving space (unique feature in the market)., Operation indication
The PFM is available in four maximum flow rate options 10, 25, 50 and 100 /min, and is suitable for use with air, nitrogen, argon or carbon dioxide. 2-color display flow switch., Sensor and monitor separation, which allows remote monitors centralization., Integrated flow adjustment valve as an option, reducing piping and saving space (unique feature in the market)., Operation indication
[Separate Type Connector Connection] Separated sensor, Output Method: Analog, Analog Output Specification: Current, Pipe Port Type: [One-Touch Couplings] One-Touch Couplings (Straight), Plumbing Thread Type: -, Plumbing Thread Nominal: -, Pressure Resistance(MPa): 1, Flow Rate Type: Standard, Operating Temperature Range(°C): -10~60, Operating Humidity Range(%): 35~85, Number of Inputs: 2,
Flow Rate Range: 25 [0.5 to 25 (12.5 for CO2) â„“/min], Flow Adjustment Valve: Yes, Port Size: ø8 (5/16") one-touch fitting, Piping Entry Direction: Straight, Output Specification: 2 [Analog Output (4 to 20 mA)], Instruction Manual: With Instruction Manual, Calibration Certificate: None, Connector: Lead Wire w/Connector (2 m), Option: Bracket for w/Flow Adjustment Valve