2.5 0.5 1 1.5 4.5 4 7.5 9.5 9 11.5 5.5 6 10 11 12 16 14.5 15 11.5 9.5 10 7.5 0 0 3.5 5.5 5 7.5 3.5 3 6.5 8.5 8 10.5 1.5 2 6 7 8 12 1.5(4) 4.5 5 9 10 11 15 2(4.5) Bore size (mm) 1.5(1) 3.5(1) 3(0.5) 5.5(3) Long stroke 12 16 20 25 32 40 1 0.5 6 8 10.5 16.5 11 10.5 16 18 20.5 26.5 9 9.5 13 14 12.5 16 5 5.5 9 10 8.5 12 7 6 11.5 13.5 16.5 22.5 5(2.5) 8 8.5 12 13 11.5 15 10 9.5 15 17 19.5 25.5
Flow Rate and Effective Area AS3001F AS2051F AS4001F AS2001F AS1001F Model Metric size 4 6 6 8 3.2, 4, 6 6 8 10, 12 10 12 Tubing O.D. 1/8", 5/32" 3/16", 1/4" 5/32" 3/16", 1/4" 3/16" 1/4", 5/16" 1/4" 5/16" 3/8" 3/8" 1/2" Inch size Controlled flow (Free flow) 100 130 230 290 460 420 660 920 1050 1390 Air flow /min (ANR) 1.5 2 3.5 4.5 7 6.5 10 14 16 21 Effective area (mm 2) Note) Flow rate values
6 q r i o e y !5 !6 !0 y i o e u r !9q !7 !0 !1 i !2 t u !7 @0 !1 q !2 t !6 !5 !7 !2 t !0 !1 Component Parts Component Parts Note Description U packing U packing Cassette Packing O ring O ring O ring O ring O ring Gasket Spacer ASD230F only Material NBR NBR Description No. !1 !2 !3 !4 !5 !6 !7 !8 !
Standard dew point temperature and air flow rate Outlet air flow rate Purge air flow rate Flow rate by size l/min (ANR) Standard dew point C Symbol Drain discharge method (Mist separator, Micro mist separator, Micro mist separator with pre-filter ) 10 100/25 20 200/50 30 300/75 50 60 3 25/6 25/3 75 100 5 50/12 50/6 20 15 500/125 600/125 750/150 1000/190 Nil H L Size and standard dew point
(Refer to graph at right.) 4) Remove the cable gland (5) and plain washer (6) and rubber seal (7). 2. Wiring 1) Pass them through the cable (8) in the order of cable ground (5), washer (6), rubber seal (7), and then insert into the housing (4). 2) Dimensions of the cable (8) are the figure as below.
MP: 6 Rc 1/2 (Supply port: Po) 4-Rc 1/2 17.5 42 70.5 119 185 5 (R1), 3 (R2) port P0 SMC 5 1 3 3 R2 R1 PE 2-Rc 1/8 (Pilot EXH port) 18 18 29 53 38 125 L n Dimensions Formula L1 = 25n + 63, L2 = 25n + 76, L3 = 25n + 269.5 (262.5) n: Stations 7 238 251 457 (435.5) 6 213 226 432 (410.5) 5 188 201 407 (385.5) 4 163 176 382 (360.5) 3 138 151 357 (335.5) 2 113 126 332 (310.5) 12 363 376 582 (560.5
6 Piston seal Rod seal NBR Set of left nos. !4, !5, !6. Gasket 6 cannot be repaired. Seal kit includes !4, !5, !6. Order the seal kit, based on each bore size. Seal kit includes a grease pack (10 g). Order with the following part number when only the grease pack is needed.
: 4-digit, 7-segment, 2-colour; red/green, Display method Sub screen: 6-digit, 11-segment, White) Display updating frequency 5 times/sec.
unit DIN rail 8-M3 3 x 7.2 ( = 21.6) 36 2-3.4 6.4 15 1 2 3 4 6.5 26 FLOW SWITCH SMC 35.5 m30 56 (4.5) 44 UNIT RESET SET 5 6 7 8 29 38 15.2 7 Series PFA Digital Flow Switch for Air Dimensions (mm)/ Separate Type For Air 1in=25.4mm Scale: 70 % PFA5 0-m m (N) 1 5 Sensor Unit 98 56 82 60 42 6 17 1.6 48.2 34 54 44 24 2-Piping port size 4-4.5 40 50 (43.5) 42 2 1 4 3 4 Connector pin numbers 43
Refer to Glossaryon page 17-3-15 for details of max. operating pressure differential and max. system pressure. 0.7 0.7 0.7 1.5 Solenoid Specifications Apparent power (VA) Inrush Holding Power consumption (W) (Holding) Temperature rise (C ) (Rated voltage) 4.5 45 3.2 35 6 55 7.5 60 6 50 8 60 11 65 9.5 60 11.5 65 Note) The return voltage is 20% or more of the rated voltage for AC and 2% or
RS-232C RS-485 5 4 1 1 Unused BUS+ 2 RD BUS 3 SD Unused 4 Unused Unused 5 SG SG 6-9 Unused Unused 9 8 7 6 3. External sensor connector (EXT.SENSOR) D-sub 15 pin (socket) Holding screw: M2.6 4 5 6 3 8 7 1 2 Pin No.
Travel to intermediate position 3 30 6.Setting of speed and acceleration General 3 positions 5 positions General 6-1 Setting of speed By adjustment of switch and , the speed of actuator is set. :Rotary switch to set speed of movement to the direction of the motor side.
Connection thread Proper tightening sizeR,NPT,G torque Nm 1/8 35 1/4 812 3/8 1520 (6) Installation of Connection thread (6)-1 For M5,10-32UNF Tightening method 1/2 2025 First, tighten it by hand, then give it an additional 1/6 turn to 1/4 turn with an appropriate wrench.. Refer to Table below for reference.
The display 6 shows "HHH". (1) Adjust the pressure to (1) Check that the pressure is not The display within the set pressure range.
Example: Cylinder diameter: 50 mm Stroke: 600 mm Working pressure: 0.5 MPa Cycles: 5 per minute Bore size: 6 mm Piping length (between the cylinder and the valve): 2 m 6.Extend the intersection point 1 upward to a 6 piping bore size. Intersection point 2 is obtained. 7.Extend the intersection point 2 rightward or leftward.
In-line Type Flow rate and effective area AS2001FM Model AS1001FM AS2051FM 8 6 3.2, 4, 6 4 6 Metric sizes Tubing O.D.
View A PFA3-B DIN rail type Sensor Blue Brown Black Analog output 1 2 3 4 3 x 7.2 (= 21.6) 8-M3 36 15 6.4 2 3.4 5 6 7 8 OUT1 N.C. Load Load 2 1 3 4 6.5 12 to 24VDC + 26 SMC FLOW SWITCH PFA312-(-M) 35.5 30 15.2 56 (4.5) 44 UNIT RESET SET Sensor Blue Brown Black Analog output 1 2 3 4 5 6 7 8 5 6 7 8 29 OUT1 N.C.
2.5 100 15.5 14.5 10.5 8 2.5 4 7 7.5 4 14 13 9 6.5 5.5 6 2.5 125 17.5 16.5 12.5 10 6 6 9 9.5 6 17.5 16.5 12.5 10 9 9.5 6 Types without air cushion have different values for auto switch mounting positions.
2 @6 t @4 w @8 r !1 @5 @3 @2 e !6 A A C B M(D)LUB25 y !9 i o !5 @0 Extension locking w q Section A-A !