SMC Corporation of America
Elite Part Number Search
Search Results "PSH-L2-01-WY"

Body/Exhaust Type: B (Single Unit - Port Exhaust), Nominal Nozzle Size: 07 (ø0.7), Supply Valve and Release Valve: R (Self-holding Release Valve Linked / N.C.), Rated Voltage: 6 (12 VDC), Vacuum Sensor: C (Digital Pressure Switch for Vacuum / 0 to -101 kPa / PNP 2 Outputs), Connector: L2 [L-type Plug Connector - w/ Lead Wire with Connector - w/o Lead Wire with Connector for Pressure Switch

Body/Exhaust Type: C (For Manifold - Common Silencer Exhaust), Nominal Nozzle Size: 07 (ø0.7), Supply Valve and Release Valve: R (Self-holding Release Valve Linked / N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: N (Without Pressure Sensor / Digital Pressure Switch for Vacuum), Connector: L2 [L-type Plug Connector - w/ Lead Wire with Connector - w/o Lead Wire with Connector for Pressure

Body/Exhaust Type: C (For Manifold - Common Silencer Exhaust), Nominal Nozzle Size: 10 (ø1.0), Supply Valve and Release Valve: R (Self-holding Release Valve Linked / N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: N (Without Pressure Sensor / Digital Pressure Switch for Vacuum), Connector: L2 [L-type Plug Connector - w/ Lead Wire with Connector - w/o Lead Wire with Connector for Pressure

Body/Exhaust Type: C (For Manifold - Common Silencer Exhaust), Nominal Nozzle Size: 10 (ø1.0), Supply Valve and Release Valve: R (Self-holding Release Valve Linked / N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: N (Without Pressure Sensor / Digital Pressure Switch for Vacuum), Connector: L2 [L-type Plug Connector - w/ Lead Wire with Connector - w/o Lead Wire with Connector for Pressure

Body/Exhaust Type: C (For Manifold - Common Silencer Exhaust), Nominal Nozzle Size: 12 (ø1.2), Supply Valve and Release Valve: R (Self-holding Release Valve Linked / N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: N (Without Pressure Sensor / Digital Pressure Switch for Vacuum), Connector: L2 [L-type Plug Connector - w/ Lead Wire with Connector - w/o Lead Wire with Connector for Pressure

. / N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: H (Digital Pressure Switch for Vacuum / -100 to 100 kPa / PNP 2 Outputs), Connector: L2 [L-type Plug Connector - w/ Lead Wire with Connector - w/o Lead Wire with Connector for Pressure Switch/sensor], Vacuum, V Port: 06 [ø6 One-touch Fitting (Metric)]

. / N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: C (Digital Pressure Switch for Vacuum / 0 to -101 kPa / PNP 2 Outputs), Connector: L2 [L-type Plug Connector - w/ Lead Wire with Connector - w/o Lead Wire with Connector for Pressure Switch/sensor], Vacuum, V Port: 08 [ø8 One-touch Fitting (Metric)]

. / N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: H (Digital Pressure Switch for Vacuum / -100 to 100 kPa / PNP 2 Outputs), Connector: L2 [L-type Plug Connector - w/ Lead Wire with Connector - w/o Lead Wire with Connector for Pressure Switch/sensor], Vacuum, V Port: 08 [ø8 One-touch Fitting (Metric)]

. / N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: H (Digital Pressure Switch for Vacuum / -100 to 100 kPa / PNP 2 Outputs), Connector: L2 [L-type Plug Connector - w/ Lead Wire with Connector - w/o Lead Wire with Connector for Pressure Switch/sensor], Vacuum, V Port: 06 [ø6 One-touch Fitting (Metric)]

. / None), Rated Voltage: 5 (24 VDC), Vacuum Sensor: C (Digital Pressure Switch for Vacuum / 0 to -101 kPa / PNP 2 Outputs), Connector: L2 [L-type Plug Connector - w/ Lead Wire with Connector - w/o Lead Wire with Connector for Pressure Switch/sensor], Vacuum, V Port: 06 [ø6 One-touch Fitting (Metric)]

. / None), Rated Voltage: 5 (24 VDC), Vacuum Sensor: H (Digital Pressure Switch for Vacuum / -100 to 100 kPa / PNP 2 Outputs), Connector: L2 [L-type Plug Connector - w/ Lead Wire with Connector - w/o Lead Wire with Connector for Pressure Switch/sensor], Vacuum, V Port: 06 [ø6 One-touch Fitting (Metric)]

Body/Exhaust Type: G (Single Unit - High-noise Reduction Silencer Exhaust), Nominal Nozzle Size: 15 (ø1.5), Supply Valve and Release Valve: R (Self-holding Release Valve Linked / N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: N (Without Pressure Sensor / Digital Pressure Switch for Vacuum), Connector: L2 [L-type Plug Connector - w/ Lead Wire with Connector - w/o Lead Wire with Connector

Body/Exhaust Type: G (Single Unit - High-noise Reduction Silencer Exhaust), Nominal Nozzle Size: 15 (ø1.5), Supply Valve and Release Valve: R (Self-holding Release Valve Linked / N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: N (Without Pressure Sensor / Digital Pressure Switch for Vacuum), Connector: L2 [L-type Plug Connector - w/ Lead Wire with Connector - w/o Lead Wire with Connector

Body/Exhaust Type: H (For Manifold - High-noise Reduction Silencer Exhaust), Nominal Nozzle Size: 07 (ø0.7), Supply Valve and Release Valve: R (Self-holding Release Valve Linked / N.C.), Rated Voltage: 6 (12 VDC), Vacuum Sensor: N (Without Pressure Sensor / Digital Pressure Switch for Vacuum), Connector: L2 [L-type Plug Connector - w/ Lead Wire with Connector - w/o Lead Wire with Connector

Body/Exhaust Type: H (For Manifold - High-noise Reduction Silencer Exhaust), Nominal Nozzle Size: 12 (ø1.2), Supply Valve and Release Valve: R (Self-holding Release Valve Linked / N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: N (Without Pressure Sensor / Digital Pressure Switch for Vacuum), Connector: L2 [L-type Plug Connector - w/ Lead Wire with Connector - w/o Lead Wire with Connector

. / N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: H (Digital Pressure Switch for Vacuum / -100 to 100 kPa / PNP 2 Outputs), Connector: L2 [L-type Plug Connector - w/ Lead Wire with Connector - w/o Lead Wire with Connector for Pressure Switch/sensor], Vacuum, V Port: 07 [ø1/4 One-touch Fitting (Inch)]

. / N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: C (Digital Pressure Switch for Vacuum / 0 to -101 kPa / PNP 2 Outputs), Connector: L2 [L-type Plug Connector - w/ Lead Wire with Connector - w/o Lead Wire with Connector for Pressure Switch/sensor], Vacuum, V Port: 07 [ø1/4 One-touch Fitting (Inch)]

Body/Exhaust Type: G (Single Unit - High-noise Reduction Silencer Exhaust), Nominal Nozzle Size: 12 (ø1.2), Supply Valve and Release Valve: R (Self-holding Release Valve Linked / N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: N (Without Pressure Sensor / Digital Pressure Switch for Vacuum), Connector: L2 [L-type Plug Connector - w/ Lead Wire with Connector - w/o Lead Wire with Connector

. / N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: C (Digital Pressure Switch for Vacuum / 0 to -101 kPa / PNP 2 Outputs), Connector: L2 [L-type Plug Connector - w/ Lead Wire with Connector - w/o Lead Wire with Connector for Pressure Switch/sensor], Vacuum, V Port: 07 [ø1/4 One-touch Fitting (Inch)]

Rated Flow Range: 11 (1 to 100 L/min), Flow Adjustment Valve: None (Straight), Port Size: N2 (NPT1/4), Output Specification: L2 (Out 1: IO-Link or NPN/PNP, Out 2: NPN, PNP, or Input), Lead Wire: W (Lead Wire w/Connector + Rubber Cover for Connector), Unit Specification: Unit Selection Function, Bracket/Panel Mount Adapter: No Bracket, Calibration Certificate: None, Made to Order: X731 (Compatible