Accuracy: Basic Type, Size: 25, Motor Mounting Position: Right Side Parallel, Motor Type: Step Motor (Servo/24 VDC), Lead Screw: LEFS16: 10mm, LEFS25: 12mm, LEFS32: 16mm, LEFS40: 20mm, Stroke: 400mm, Motor Option: w/o Option, Positioning Pin Hole: Housing B Bottom, Actuator Cable Type: Robotic Cable, Flexible Cable, Actuator Cable Length: 5m, Controller/Driver Type: -, I/O Cable, Communication
Accuracy: Basic Type, Size: 32, Motor Mounting Position: Right Side Parallel, Motor Type: Step Motor (Servo/24 VDC), Lead Screw: LEFS16: 10mm, LEFS25: 12mm, LEFS32: 16mm, LEFS40: 20mm, Stroke: 300mm, Motor Option: w/o Option, Positioning Pin Hole: Housing B Bottom, Actuator Cable Type: Robotic Cable, Flexible Cable, Actuator Cable Length: 5m, Controller/Driver Type: -, I/O Cable, Communication
Accuracy: Basic Type, Size: 32, Motor Mounting: Top Mounting Position, Motor Type: T7 [AC Servo Motor, (Absolute Encoder), Output 200W], Lead: C [LEY25, 3mm; LEY32, 4(5)mm], Stroke: 350mm, Motor Option: B (w/Lock), Rod End Thread: M (Rod End Male Thread, 1 Rod End Nut Included), Mounting: Ends Tapped (Standard), Cable Type: R (Robotic Cable, Flexible Cable), Cable Length: 5m, Driver: w/o
Size: 100, Motor Mounting Position: FL (Left), Motor Type: T9 (AC Servo w/ Absolute encoder, 750W output, LECS compatible), Lead (mm): L (1/5 reduction: LET80: 26, LET100: 48), Stroke: 2000mm, Motor Option: Nil (without option), Cable Type: R (Robotic Cable), Cable Length: 5 (5m), Driver Type: Nil (without driver), I/O Cable Length: Nil (without cable)
Size: 100, Motor Mounting Position: FR (Right), Motor Type: T9 (AC Servo w/ Absolute encoder, 750W output, LECS compatible), Lead (mm): L (1/5 reduction: LET80: 26, LET100: 48), Stroke: 2000mm, Motor Option: Nil (without option), Cable Type: R (Robotic Cable), Cable Length: 5 (5m), Driver Type: Nil (without driver), I/O Cable Length: Nil (without cable)
Size: 100, Motor Mounting Position: FL (Left), Motor Type: T9 (AC Servo w/ Absolute encoder, 750W output, LECS compatible), Lead (mm): L (1/5 reduction: LET80: 26, LET100: 48), Stroke: 1200mm, Motor Option: Nil (without option), Cable Type: R (Robotic Cable), Cable Length: 5 (5m), Driver Type: Nil (without driver), I/O Cable Length: Nil (without cable)
Size: 100, Motor Mounting Position: FR (Right), Motor Type: T9 (AC Servo w/ Absolute encoder, 750W output, LECS compatible), Lead (mm): N (1/15 reduction: LET100: 16), Stroke: 600mm, Motor Option: B (with Lock), Cable Type: R (Robotic Cable), Cable Length: 5 (5m), Driver Type: Nil (without driver), I/O Cable Length: Nil (without cable)
Size: 100, Motor Mounting Position: FL (Left), Motor Type: T9 (AC Servo w/ Absolute encoder, 750W output, LECS compatible), Lead (mm): M (1/9 reduction: LET80: 14.44, LET100: 26.67), Stroke: 2000mm, Motor Option: B (with Lock), Cable Type: R (Robotic Cable), Cable Length: 5 (5m), Driver Type: Nil (without driver), I/O Cable Length: Nil (without cable)
Size: 80, Motor Mounting Position: FL (Left), Motor Type: T8 (AC Servo w/ Absolute encoder, 400W output, LECS compatible), Lead (mm): L (1/5 reduction: LET80: 26, LET100: 48), Stroke: 1200mm, Motor Option: Nil (without option), Cable Type: R (Robotic Cable), Cable Length: 5 (5m), Driver Type: Nil (without driver), I/O Cable Length: Nil (without cable)
Magnet: D (Built-in Magnet), Mounting: D (Double Clevis), Bore Size: 32mm, Stroke: 50mm, Rod Boot: w/o Rod Boot, Rod: Single Rod, Pivot Bracket: N (Pivot Bracket), Rod End Bracket: No Bracket, Auto Switch: M9P--Solid State, Gen. Purpose, 3 Wire PNP, Horizontal, Lead Wire or Prewired Connector: Z (5m)
Cylinder (Tube) Inner Diameter(φ): 20, Stroke(mm): 50, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Cushion: Air cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet, Support bracket: None, Auto Switches: Without auto switch
Cylinder (Tube) Inner Diameter(φ): 20, Stroke(mm): 50, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Cushion: Air cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet, Support bracket: None, Auto Switches: Without auto switch
Cylinder (Tube) Inner Diameter(φ): 25, Stroke(mm): 50, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Cushion: Air cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet, Support bracket: None, Auto Switches: Without auto switch
Cylinder (Tube) Inner Diameter(φ): 25, Stroke(mm): 50, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Cushion: Air cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet, Support bracket: None, Auto Switches: Without auto switch
Cylinder (Tube) Inner Diameter(φ): 25, Stroke(mm): 50, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Cushion: Air cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet, Support bracket: None, Auto Switches: Without auto switch
This is a legacy product. Please contact us for the latest version.sales@ocaire.com
This is a legacy product. Please contact us for the latest version.sales@ocaire.com
This is a legacy product. Please contact us for the latest version.sales@ocaire.com
Cylinder (Tube) Inner Diameter(φ): 20, Stroke(mm): 50, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Cushion: Air cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet, Support bracket: None, Auto Switches: Without auto switch
Cylinder (Tube) Inner Diameter(φ): 20, Stroke(mm): 50, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Cushion: Air cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet, Support bracket: None, Auto Switches: Without auto switch