Lock: None, Body Shape: D (Mounting Tap: 4xM10x1.5, Pin Hole: 2xø8H7), Mounting Surface: B (Same Side as Port Location), Bore Size: 50mm, Port Thread: TF (G), Guide Pin Diameter: 250 (25.0mm), Guide Pin Shape: R (Round Type), Clamp Arm Position: B (90° From Port), Clamping Height: H (High Type), Shim: S (With 3mm Shims), Auto Switch: P74--Reed, DC Volt, AC Volt, High Magnetic Field Resistant
Lock: None, Body Shape: D (Mounting Tap: 4xM10x1.5, Pin Hole: 2xø8H7), Mounting Surface: A (90° from Port Location), Bore Size: 50mm, Port Thread: TF (G), Guide Pin Diameter: 250 (25.0mm), Guide Pin Shape: R (Round Type), Clamp Arm Position: B (90° From Port), Clamping Height: H (High Type), Shim: None, Auto Switch: P79W--Reed, 2-color Indication, High Magnetic Field Resist., 2 Wire, Lead
Cylinder Inner Diameter: D(φ): 32, Stroke: L(mm): 250, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Guided, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Cushion: Air Cushion, Port thread type: G, Auto Switches: Without auto switch, Lead Wire Length(m): N/A, The number
Cylinder Inner Diameter: D(φ): 32, Stroke: L(mm): 250, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Guided, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Cushion: Air Cushion, Port thread type: G, Auto Switches: Without auto switch, Lead Wire Length(m): N/A, The number
Cylinder Inner Diameter: D(φ): 40, Stroke: L(mm): 250, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Guided, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Cushion: Air Cushion, Port thread type: G, Auto Switches: Without auto switch, Lead Wire Length(m): N/A, The number
Cylinder Inner Diameter: D(φ): 63, Stroke: L(mm): 250, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Guided, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Cushion: Air Cushion, Port thread type: G, Auto Switches: Without auto switch, Lead Wire Length(m): N/A, The number
Cylinder Inner Diameter: D(φ): 32, Stroke: L(mm): 250, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Guided, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Cushion: Air Cushion, Port thread type: G, Auto Switches: Without auto switch, Lead Wire Length(m): N/A, The number
Cylinder Inner Diameter: D(φ): 32, Stroke: L(mm): 250, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Guided, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Cushion: Air Cushion, Port thread type: G, Auto Switches: Without auto switch, Lead Wire Length(m): N/A, The number
Cylinder Inner Diameter: D(φ): 40, Stroke: L(mm): 250, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Guided, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Cushion: Air Cushion, Port thread type: G, Auto Switches: Without auto switch, Lead Wire Length(m): N/A, The number
Cylinder Inner Diameter: D(φ): 63, Stroke: L(mm): 250, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Guided, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Cushion: Air Cushion, Port thread type: G, Auto Switches: Without auto switch, Lead Wire Length(m): N/A, The number
(Or None in the Case of No Switch), Lock Unit Built-in Magnet: D (Built-in)
(Or None in the Case of No Switch), Lock Unit Built-in Magnet: D (Built-in)
Series: NCDA1 (Standard w/ Magnet), Mounting: D (MP2, Detachable Rear Clevis), Bore Size: 250 (2 1/2"), Stroke: 3600 (36"), Air Cushion / Rod Boot: Both Ends (Air Cushion), Thread: Nil (Small Male, Standard, Threaded), Adjustment Range: Not Applicable, Auto Switch: M9PW--Solid State, 2-color Indication, 3 Wire PNP, Horizontal, Lead Wire or Prewired Connector: L (3m), Number: 2 pcs.
Magnet: None, Mounting: B (Through Hole), Overall Length: Standard, Bore Size: 250 (2 1/2"), Stroke: 250 (2 1/2"), Body Option: Standard (Rod End Female Thread), Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), X Option: XB6 (High Temperature)
Magnet: None, Mounting: C (Rear Clevis), Overall Length: Standard, Bore Size: 250 (2 1/2"), Stroke: 250 (2 1/2"), Body Option: M (Male Rod End), Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), X Option: XB6 (High Temperature)
Magnet: None, Mounting: C (Rear Clevis), Overall Length: Standard, Bore Size: 250 (2 1/2"), Stroke: 250 (2 1/2"), Body Option: Standard (Rod End Female Thread), Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), X Option: XC4 (Scraper)
Magnet: None, Mounting: A (Both Ends Tapped), Overall Length: Standard, Bore Size: 250 (2 1/2"), Stroke: 250 (2 1/2"), Body Option: Standard (Rod End Female Thread), Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), X Option: XC4 (Scraper)
Magnet: None, Mounting: A (Both Ends Tapped), Overall Length: Standard, Bore Size: 250 (2 1/2"), Stroke: 250 (2 1/2"), Body Option: Standard (Rod End Female Thread), Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), X Option: XB6 (High Temperature)
Magnet: None, Mounting: B (Through Hole), Overall Length: Standard, Bore Size: 250 (2 1/2"), Stroke: 250 (2 1/2"), Body Option: Standard (Rod End Female Thread), Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), X Option: XC4 (Scraper)
Element Size: 100 (ø65 x â„“250), Nominal Filtration Accuracy: 10 μm, Element Seal Material: V (FKM)