Even for the built-in contact protection circuit type (D-A34[A][C], DA44[A][C], D-A54/A64, D-A59W, D-B59W), use the contact protection box when the wiring length to load is very long (over 30 m) and PLC (Programmable Logic Controller) with a large inrush current is used. Contact Protection Box Specifications CD-P11 CD-P12 Part no.

[C]: Not used. Items don't need to be changed. OFF < [A] Movement MOD> Set Absolute for the absolute positioning and Relative for the relative positioning. Refer to 3.1 Positioning operation for details. < [A] Speed> Transfer speed to the target position. < [A] Position> Target position. < [B] Acceleration> The parameter which defines the starting speed to be gradually or rapidly.

If driving a load such as a relay that generates a surge voltage, use a switch with a built-in contact protection circuit or use a contact protection box. 1) For an auto switch without a contact protection circuit, use a contact protection box when the wire length is 50m or longer.

Avoid using and storing this product in the following environments since they may cause damage to this product. a) Avoid using in a place that exceeds an ambient temperature range of 0 to 55C. b) Avoid using in a place that exceeds an ambient humidity range of 35 to 65% Rh. c) Avoid using in a place where condensation occurs due to a drastic temperature change. d) Avoid using in a place in

(mm) At the minimum stroke of standard adjustment bolt At the minimum stroke of 25 mm adjustment bolt Basic stroke At maximum stroke adjustment Bore size (mm) Bore size (mm) 10 15 25 Adjustment bolt fixing bolts Tightening torque Adjustment width across flats 10 15 25 A 2 A 26 A = 0.8 A = 0.6 A 0 M3 1.0 to 1.3 Nm 4 A 2 A 26 M5 4.6 to 6.2 Nm 5 Adjuster holder A Adjuster holder Adjustment

Bore size (mm) D-A73/A80 D-F7NT Electrical entry (Fetching direction) Type Model Features D-F7NT Solid state auto switch Grommet (In-line) With timer A B A B A B With pre-wired connector is available for D-F7NT type, too.

When a surge generating a load such as a relay or solenoid is directly driven, use a type of switch with a built-in surge absorbing element. 4. Since the type of fluid varies depending on the product, be sure to verify the specifications. The switches do not have an explosion proof rating. To prevent a possible fire hazard, do not use with flammable gases or fluids. 5.

1 2 Holding block (A) 1 2 1 Switch block (A) 1 1 Switch block (B) 1 1 Holding block (A) 1 No.

Do not use a load that generates surge voltage. Although a zener diode for surge protection is connected at the output side of a solid state auto switch, damage may still occur if the surge is applied repeatedly. When a load, such as a relay or solenoid, which generates surge is directly driven, use a type of switch having a built-in surge absorbing element. 8.

5 V Current output*1 4 mA 4.16 mA 20 mA B D 0 L/min C*2 D Voltage output (0 to 10 V)*1*3 0 V 0.1 V 10 V Model Minimum value of rated flow range*4 Maximum value of rated flow range PF3A703H 30 L/min 3000 L/min PF3A706H 60 L/min 6000 L/min PF3A712H 120 L/min 12000 L/min A C 0 0 *1 Analog output accuracy is within 3% F.S. *2 A and C will change according to the setting of the zero cut function

Only when output 1 and 2 are in the ON state, and C turns ON, will output 3 turn ON. If either A or B is turned OFF , output 3 will not be turned ON, even if C is turned ON.

Booster regulator VBA200 VBA400 VBA11 VBAT05(S) Air tank VBAT10(S) VBAT20(S) VBAT38(S) 14-9-7 8 VBAT05 to 38 Related Products: Model (Material: Carbon steel) This is a small capacity air tank to which a booster valve can be connected directly in a compact manner. It does not comply with the Class 2 Pressure Vessel requirement. It can be used alone as a tank.

Diaphragm Assembled in a clean room.

Fittings & Tubing Air Cylinders Rotary Actuators Relief port 2 x M5 x 0.8 2 x P through M5 x 0.8 R GC GB E GA MM D C J 2.8 2 x P through A 4 x T counterbore E 0.5 B H S Z (mm) 6 depth 4.8 5 S 10 15 20 25 30 5 Z 10 15 20 25 30 Bore size B C D E GA GB GC H J MM P R T A 13 22 3 23 16 15 13 10 3.2 7 M3 x 0.5 31 10 7 6 10 15 24 4 24 33.5 16 15.5 16 11 M4 x 0.7 3.2 9 6 depth 5 64 69 74 79 84 89

Select the point of contact A of inlet pressure and max. air capacity in the graph. 2. AMH650 is obtained when the max. flow line is aboveabove the point of intersection A in the graph. Note) Make sure to select a model that has the maximum flow rate line above the obtained intersecting point.