No. 1 1 1 1 1 M3 M3 M3 M3 1/4 0.4~0.5Nm 1) 1) 1) 1) [ [ [ [ ] ] ] ] 1 ()ISO VG32 (MSDS) [ [ [ [ ] ] ] ] 1 ()ISO VG32 2 ()ISO VG32 (MSDS) 6 No.VQZ100V-OMT0001 VQZ VQZ VQZ VQZ 3 3 3 3 5 5 5 5 / / / / , ( ( ( ( ) ) ) ) 5m ( ( ( ( ) ) ) ) 3 30 ( ) 1 ()ISO VG32 2 ()ISO VG32 IP65 (IEC60529) IP65 7 No.VQZ100V-OMT0001 VQZ Series/ / / / L L L L /M /M /M /M ()() VQZ100 VQZ100 VQZ100
No. 1 1 1 1 1 M3 M3 M3 M3 1/4 0.4~0.5Nm 2 2 2 2 M5 M5 M5 M5 1/6~1/4 1~1.5Nm 1) 1) 1) 1) ISO VG32 (MSDS) 6 No.VP300-OMP0001 VP Series VP Series VP Series VP Series 3 3 3 3 / / / / ( ( ( ( ) ) ) ) ( ( ( ( ) ) ) ) 30 () 1 ()ISO VG32 2 ()ISO VG32 IP65 (IEC60529) IP65 7 No.VP300-OMP0001 VP Series VP Series VP Series VP Series/ / / / L L L L /M /M /M /M 3.2~3.7mm () (+-) () (1mm
Pressure Control Equipment O-ring Cross recessed round head screws (with SW) (M3) End block Tie-rod For common supply blocks, reversible and double-sided mounting is available. Common supply tie-rod Industrial Filters Cross recessed round head screws (with SW) (M3) Tightening torque: 0.32 0.03 Nm 451 Series ARM5A/5B/5S Replacement Procedure of Diaphragm 4 4.
Applicable mounting screw: M3 (2 pcs.)
Dimensions (mm) Weight (g) Effective area (mm2) Recommended flow (m3/min (ANR)) Port size R Model A B C 1 8 1 4 3 8 1 2 3 4 1 1 1 14 64 22 18 ANA1-01 ANA1-02 ANA1-03 ANA1-04 ANA1-06 ANA1-10 ANA1-12 ANA1-14 ANA1-20 4 37 16 10 15 35 60 90 160 280 450 610 0.8 or less 1.2 or less 2.7 or less 4.5 or less 7.0 or less 12.0 or less 20.0 or less 32.0 or less 45.0 or less 84 25 21 98 30 24 111 46
Thread sizes range from M3 to 2 and are available in both inch (NPT) and metric R/Rc(PT)Speed controller standard in-line style, Body sizes: M3, M5, 1/8, 1/4, 3/8, 1/2, Port sizes: M3, M5, 01, 02, 03, 04, SPEED CONTROLLER, INLINE TYPE, AIRLINE EQUIPMENT, AS FLOW CONTROL, FB, AS 1/2INCH STANDARD (PT), .50080 lb, ModelPort sizeFree flowControlled flowApplicable cylinder bore size
(SI unit side) Valve manifold Output No. 1 3 5 7 9 17 29 31 Solenoid on side B Accessories Bit No. 1 3 5 7 1 1 5 7 Replacement of the SI unit Remove the M3 hexagon screw from the SI unit and release the SI unit from the valve manifold. Replace the SI unit.
(M3 thread) (It is recommended to ground with resistance of 100 ohms or less) Accessories Hexagon socket head cap screw (M3 x 30): 2 pcs. Connects the SI unit and the valve manifold. Seal cap: 1 pc.
(M3 screw) 5 Output connector Output signal interface for valve manifold. 6 LED display LED display to indicate the status of the SI unit. 2 7 Mounting hole Mounting hole for connection to the valve manifold. Accessories Hexagon socket head cap screw 2 pcs. M3 x 30 screw for connection to the valve manifold.
0.5 ~0.6 Nm + G 1/2 M3 0.5 ~0.6 Nm M3 0.5 ~0.6 Nm A-A () 1) 2) 3) 30 1) 2) 1 0.1MPa 5 VN-OMP0002 Series Series Series Series 1 DC AC VT307 VNA ( ) (JIS B2301)(JIS B 2302) VNA (JIS B 6349) VNA 1 ISO VG32 VNA ( JIS K 6439) VNA VNA VNA VNA AS AS AS AS VNA AS 10A 111 420-03 3/8 B(9.5) 12 12 12 12(P1) (P1) (P1) (P1) 10(P2) 10(P2) 10(P2) 10(P2) 12(P1)10(P2) 15A 211 420-04 1/2 B
0.5 ~0.6 Nm + G 1/2 M3 0.5 ~0.6 Nm M3 0.5 ~0.6 Nm A-A () 6 VN-OMP0001 VNC VNC VNC VNC VNH VNH VNH VNH / / / / 1 DC AC VT307 12(P1) 12(P1) 12(P1) 12(P1) 10(P2) 10(P2) 10(P2) 10(P2) 12(P1)10(P2) Air operated Solenoid Port VNC02 12 (P1) External pilot Bleed port External pilot 10 (P2) Bleed port External pilot Pilot exhaust Ass Ass Ass Ass y y y y VNH VNH VNH VNH () 3 3 3 3
After checking the detection position, tighten M3 screws to fix the auto switch so that the bottom of the auto switch contact the cylinder tube. (The tightening torque of the M3 screw must be 0.5 to 0.7Nm.) Tighten the auto switch mounting screw(M4) to fix the auto switch mounting bracket.
After checking the detection position, tighten M3 screws to fix the auto switch so that the bottom of the auto switch contact the cylinder tube. (The tightening torque of the M3 screw must be 0.5 to 0.7Nm.) Tighten the auto switch mounting screw(M4) to fix the auto switch mounting bracket.
Direct installation For direct mounting, use M3 screws (2 pcs.) or equivalent. The recommended tightening torque of the screw is 0.5 to 0.7 Nm. Mount the product on a flat and even surface. Mounting on an uneven surface can damage the case. Screws and washers should be supplied by the user.
Model Bolt Max.tightening Torgue (Nm) JMHZ2-16D M3 x 0.5 0.59 Attachment 21 - How to Mount Air Gripper (1)Mounting orientation: On robot arm(s) (2)Mounting to the cover Take care not to get the switch cable caught when mounting the cover.
Piping to products When piping to a product, avoid mistakes regarding the supply port, etc. 1) When using SMCs M3 or M5 fittings, follow the procedures below to tighten them. Mounting Connection thread: M3 1. Operation manual Warning First, tighten by hand, then use a suitable wrench to tighten the hexagonal portion of the body an additional 1/4 turn.
(M3 screw) 5 Output connector Output signal interface for valve manifold. 6 LED display LED display to indicate the status of the SI unit. 2 7 Mounting hole Mounting hole for connection to the valve manifold. Accessories Hexagon socket head cap screw 2 pcs. M3 x 30 screw for connection to the valve manifold.
(M3 thread) (It is recommended to ground with resistance of 100 ohms or less) Accessories Hexagon socket head cap screw (M3 x 30): 2 pcs. Connects the SI unit and the valve manifold. Seal cap: 1 pc.
Match polarity between solenoid valve and SI unit output. -30No.EX-OMW0016-A Maintenance Replacement of the SI unit Remove the M3 hexagon screws from the SI unit and release the SI unit from the solenoid valve manifold. Replace the SI unit.
Screw Max. tightening torque (Nm) Maximum screw-in depth (mm) MHZ2-6 MHZJ2-6 M3 x 0.5 0.88 10 MHZA2-6 MHZAJ2-6 Model No. Screw Max. tightening torque (Nm) MHZ2-6 MHZJ2-6 M2.5x0.45 0.49 MHZA2-6 MHZAJ2-6 8 - Caution 1. Avoid twisting the gripper when mounting an attachment. Any damage to the gripper may cause malfunction and reduce the accuracy. 2. Avoid external force to fingers.