The ZSE40A(F) is also CE, UL/CSA and RoHS compliant.High precision digital pressure switch w/2-color display , IP65 and RoHS compliant , Capable of copying up to 10 switches simultaneously , 3-step setting , Space saving design w/several piping and mounting variations, SWITCH, VACUUM SERIES, ZSE40/50/60 VACUUM SWITCH, 1C, ZSE40/50/60 OTHER SIZE RATING, .15747 lb, ModelRated pressure
Please contact us for the latest version.sales@ocaire.com, SWITCH, VACUUM SERIES, ZSE40/50/60 VACUUM SWITCH, JC, ZSE40/50/60 1/8 PORTED, .35273 lb, ModelRated pressure rangeDisplay/Set pressure rangeWithstand pressureDisplay/Minimum unit settingApplicable fluidPower supply voltageCurrent consumptionSwitch output--Repeat accuracyHysteresisAnalog outputAuto-shift inputDisplayDisplay
This is a legacy product, and replaced byISE20B-X-P-N01-W, SWITCH, INSTRUMENTATION, ISE40/50/60 PRESSURE SWITCH, CB, ISE40/50/60 1/8 NPT VERSION, .21220 lb, ModelRated pressure rangeDisplay/Set pressure rangeWithstand pressureDisplay/Minimum unit settingApplicable fluidPower supply voltageCurrent consumptionSwitch output--Repeat accuracyHysteresisAnalog outputAuto-shift inputDisplayDisplay
The settings of the master pressur, SWITCH, INSTRUMENTATION, ISE40/50/60 PRESSURE SWITCH, CA, ISE40/50/60 1/8 PT VERSION, .38212 lb, ModelRated pressure rangeDisplay/Set pressure rangeWithstand pressureDisplay/Minimum unit settingApplicable fluidPower supply voltageCurrent consumptionSwitch output--Repeat accuracyHysteresisAnalog outputAuto-shift inputDisplayDisplay accuracyIndicator
10%, Ripple (p-p) 10% or less (with power supply polarity protection)45 mA or lessNPN or PNP open collector 2 outputs (Selectable)80 mA28 V (at NPN output)1 V or less2.5 ms (with anti-chattering function: 20, 100, 500, 1000, 2000 ms)Yes?0.2% F.S. ?1 digitVariable (0 or above) Note 1)Variable (0 or above) Note 1)1 to 5 V ?2.5% F.S.?1% F.S. or lessApprox. 1 k 4 to 20 mA ?2.5% F.S.?
This is a legacy product, and replaced byZSE20B-Y-P-N01-W, SWITCH, VACUUM SERIES, ZSE40/50/60 VACUUM SWITCH, JD, ZSE40/50/60 1/8 PORTED, .17416 lb, ModelRated pressure rangeDisplay/Set pressure rangeWithstand pressureDisplay/Minimum unit settingApplicable fluidPower supply voltageCurrent consumptionSwitch output--Repeat accuracyHysteresisAnalog outputAuto-shift inputDisplayDisplay
The settings of the master pressur, SWITCH, INSTRUMENTATION, ISE40/50/60 PRESSURE SWITCH, 1X, ISE40/50/60 OTHER SZ (OTHER), .29312 lb, ModelRated pressure rangeDisplay/Set pressure rangeWithstand pressureDisplay/Minimum unit settingApplicable fluidPower supply voltageCurrent consumptionSwitch output--Repeat accuracyHysteresisAnalog outputAuto-shift inputDisplayDisplay accuracyIndicator
Please contact us for the latest version.sales@ocaire.com, SWITCH, VACUUM SERIES, ZSE40/50/60 VACUUM SWITCH, 1C, ZSE40/50/60 OTHER SIZE RATING, .28660 lb, ModelRated pressure rangeDisplay/Set pressure rangeWithstand pressureDisplay/Minimum unit settingApplicable fluidPower supply voltageCurrent consumptionSwitch output--Repeat accuracyHysteresisAnalog outputAuto-shift inputDisplayDisplay
The settings of the master pressur, SWITCH, INSTRUMENTATION, ISE40/50/60 PRESSURE SWITCH, 1X, ISE40/50/60 OTHER SZ (OTHER), .25633 lb, ModelRated pressure rangeDisplay/Set pressure rangeWithstand pressureDisplay/Minimum unit settingApplicable fluidPower supply voltageCurrent consumptionSwitch output--Repeat accuracyHysteresisAnalog outputAuto-shift inputDisplayDisplay accuracyIndicator
The settings of the master pressur, SWITCH, INSTRUMENTATION, ISE40/50/60 PRESSURE SWITCH, CB, ISE40/50/60 1/8 NPT VERSION, .17416 lb, ModelRated pressure rangeDisplay/Set pressure rangeWithstand pressureDisplay/Minimum unit settingApplicable fluidPower supply voltageCurrent consumptionSwitch output--Repeat accuracyHysteresisAnalog outputAuto-shift inputDisplayDisplay accuracyIndicator
The settings of the master pressur, SWITCH, INSTRUMENTATION, ISE40/50/60 PRESSURE SWITCH, CB, ISE40/50/60 1/8 NPT VERSION, .17416 lb, ModelRated pressure rangeDisplay/Set pressure rangeWithstand pressureDisplay/Minimum unit settingApplicable fluidPower supply voltageCurrent consumptionSwitch output--Repeat accuracyHysteresisAnalog outputAuto-shift inputDisplayDisplay accuracyIndicator
Settable range : 10...988 (1.0 kPa...98.8 kPa) Combination conditions with other parameters : 10 H1 P1-1 (50) ... ... ... ... ... 16 2 R/W 0x0032 Vacuum confirmation hysteresis (H1) of CH15 (50) 3.4.3. Pressure P2 (Index 66) Table 3-11.
V114-5LU Fluid Air Ambient and operating fluid temperature(oC) -10 to 50 (No freezing) Response time [ms] ON5 or less OFF4 or less Minimum operation frequency [Hz] 20 Lubrication Not required Mounting orientation Free Impact resistance/Vibration resistance (m/s2) 15030 Enclosure rating Dustproof Model No.
V114-5LU Fluid Air Ambient and operating fluid temperature(oC) -10 to 50 (No freezing) Response time [ms] ON5 or less OFF4 or less Minimum operation frequency [Hz] 20 Lubrication No Mounting orientation Free Impact resistance/Vibration resistance (m/s2) 15030 Enclosure rating Dustproof Model No.
V114-5LU Fluid Air Ambient and operating fluid temperature(oC) -10 to 50 (No freezing) Response time [ms] ON5 or less OFF4 or less Minimum operation frequency [Hz] 20 Lubrication Non-lube Mounting orientation Free Impact resistance/Vibration resistance (m/s2) 15030 Enclosure rating Dustproof Model No.
3/8, 1/2 70 147.1 25.5 35.5 38.4 75 35.5 50 52 30 8.5 12.5 88 2.3 39 186.9 AFD40-06-D 3/4 75 149.1 27 35.5 38.4 75 35.5 50 52 34 8.5 12.5 88 2.3 43 188.9 Semi-standard specifications PC/PA bowl Metal bowl with Metal bowl level gauge With element Model With With With With With With service indicator barb drain drain drain drain drain fitting guide cock guide cock guide B B B B B B A C1 AFD20
The settings of the master pressur, SWITCH, INSTRUMENTATION, ISE40/50/60 PRESSURE SWITCH, CA, ISE40/50/60 1/8 PT VERSION, .47265 lb, ModelRated pressure rangeDisplay/Set pressure rangeWithstand pressureDisplay/Minimum unit settingApplicable fluidPower supply voltageCurrent consumptionSwitch output--Repeat accuracyHysteresisAnalog outputAuto-shift inputDisplayDisplay accuracyIndicator
Please contact us for the latest version.sales@ocaire.com, SWITCH, INSTRUMENTATION, ISE40/50/60 PRESSURE SWITCH, CA, ISE40/50/60 1/8 PT VERSION, .38605 lb, ModelRated pressure rangeDisplay/Set pressure rangeWithstand pressureDisplay/Minimum unit settingApplicable fluidPower supply voltageCurrent consumptionSwitch output--Repeat accuracyHysteresisAnalog outputAuto-shift inputDisplayDisplay
Please contact us for the latest version.sales@ocaire.com, SWITCH ASSEMBLY, INSTRUMENTATION, ISE40/50/60 PRESSURE SWITCH, CA, ISE40/50/60 1/8 PT VERSION, .38605 lb, ModelRated pressure rangeDisplay/Set pressure rangeWithstand pressureDisplay/Minimum unit settingApplicable fluidPower supply voltageCurrent consumptionSwitch output--Repeat accuracyHysteresisAnalog outputAuto-shift inputDisplayDisplay
The settings of the master pressur, SWITCH ASSEMBLY, INSTRUMENTATION, ISE40/50/60 PRESSURE SWITCH, CA, ISE40/50/60 1/8 PT VERSION, .38475 lb, ModelRated pressure rangeDisplay/Set pressure rangeWithstand pressureDisplay/Minimum unit settingApplicable fluidPower supply voltageCurrent consumptionSwitch output--Repeat accuracyHysteresisAnalog outputAuto-shift inputDisplayDisplay accuracyIndicator