Wiring example when using manifold power supply terminals Inner wiring of SX manifold (Flat ribbon cable, Positive common specification) SV Control side (PLC, etc) (NPN open collector output) PLC (Programmable Logic Controller) SZ Negative pin SY Manifold valve (SS5X3-45PGD-05U-) SYJ SX DC power supply Solenoid valve Triangle mark Cable assembly Power supply terminal AXT100-FC20-, etc.
Wiring example when using manifold power supply terminals Inner wiring of SX manifold (Flat ribbon cable, Positive common specification) SV Control side (PLC, etc) (NPN open collector output) PLC (Programmable Logic Controller) SZ Negative pin SY Manifold valve (SS5X3-45PGD-05U-) SYJ SX DC power supply Solenoid valve Triangle mark Cable assembly Power supply terminal AXT100-FC20-, etc.
If the pressure differential at each port exceeds the values in the table below, valve leakage may occur. 2 Standard coil Coil with power-saving circuit DC circuit 1 1 (+, ) Red (+) Power-saving circuit 2 Port Valve SOL. SOL. Max. operating pressure differential (MPa) Orifice diameter (mm ) Model 2 (, +) Black () Pressure port 1 2. Apply the correct voltage.
Basic type Pilot Solenoid Valve Specifications VEX5511/5711/5911/5501/5701/5901 SF4--20 Grommet (G), Grommet terminal (E), Conduit terminal (T), DIN terminal (D) Pilot valve Model Electrical entry Coil rated voltage (V) AC (50/60Hz) DC Allowable voltage 100 V, 200 V, Other (Option) 24 V, Other (Option) 15 to +10% of rated voltage Inrush AC Holding DC 5.6 VA (50Hz), 5.0 VA (60Hz) 3.4 VA (50Hz
Class B or equivalent (130C) Coil insulation 100 VA 50 Hz Inrush Symbol Specifications 90 VA 60 Hz AC Apparent power Note) -XA Change of rod end shape 20 VA 50 Hz Holding -XC4 With heavy duty scraper 14 VA 60 Hz Piston rod and rod end nut made of stainless steel Note) Power consumption 13.2 W DC -XC6 Note) At the rated voltage.
Load voltage Lead wire (m) Mounting bracket Bore size Indicator Applicable load Auto switch model Special function Style Electrical entry Wiring (Output) 0.5 () 3 (L) 5 (Z) 32 BT-03 AC DC 40 BT-03 3 wire (Equiv. to NPN) 5V A56 IC 50 BT-04 Yes Reed switch Solid state switch A53 A54 A67 A64 A59W F59 F5P J51 J59 F59W F5PW J59W F5BA F5NT F59F 12V 5V,12V 100V,200V 63 BT-04 Grommet Relay PLC
(42mA) 1W DC (83mA) 1 (P) 5 (R1) 3 (R2) 3-position closed center (A) 4 (B) 2 Power consumption (Current) 24VDC 12VDC < = Note 1) Operating pressure Pilot pressure Note 2) Use dry air to prevent condensation at low temperatures.
Lube unit S1 Thread type 1a (without oil OFF) ALDU600 (with panel) S2 Nil Rc NPT Body size (Standard) N 6 9 1B 2B Accessory Port size Float Switch Specifications Symbol Description Nil Bracket Panel 4 3 06 10 12 14 20 Voltage Max. contact capacity Max. operating current Contact point construction Level indication 200 VAC, 200 VDC 50 VA AC, 50 W DC 0.5 A AC, 0.5 A DC 1a, 1b Bottom limit indication
2 W 3.2 W (Energy saving type) Note 4) (Inrush 3.2 W, Holding 1.0 W) DC Power consumption M plug connector Body ported M plug connector Base mounted L plug connector, M plug connector With light/surge voltage suppressor Electrical entry Note 1) Based on dynamic performance test, JIS B 8374-1981.
1021Series VQ1000 Base Mounted Plug-in Unit Note) For CE compliant models, DC-type only. [Option] How to Order Manifold VV5Q 1 1 08 C6 U1 F 10 CE compliant Series Nil CE compliant VQ1000 1 Q Note) For CE compliant models, DC-type only.
*1 Soft Start-up Valve AV2000-A/3000-A/4000-A/5000-A Series 2(A) Symbol How to Order (P)1 3(R) *1 CE compliant AV 00 20 02 B B 1 D q w e r t y u i o A Electrical entry Grommet DIN terminal AC V DC V V V q Body size 20 30 40 50 Symbol Description w Thread type Nil Rc V V V V N NPT V V V V F G V V V V + 02 1/4 V 03 3/8 V 04 1/2 V 06 3/4 V 10 1 V + e Port size 1(P), 2(A) a Mounting Nil
1021Series VQ1000 Base Mounted Plug-in Unit Note) For CE compliant models, DC-type only. [Option] How to Order Manifold VV5Q 1 1 08 C6 U1 F 10 CE compliant Series Nil CE compliant VQ1000 1 Q Note) For CE compliant models, DC-type only.
Compact Electro-Pneumatic Regulator Series ITV0 RoHS How to Order For single unit and single unit for manifold ITV00 1 0 0 N Pressure range 0.1 MPa 0.5 MPa 0.9 MPa Cable connector (Option) 1 3 5 Power supply voltage Without cable connector Straight type 3 m Right angle type 2 m N S L 24 VDC 10% 12 to 15 VDC 0 1 Input signal Current type 4 to 20 mA DC (Sink type) Current type 0 to 20 mA DC
N.O. 125 AC 250 AC 30 DC 125 DC 5 3 4 0.4 3 2 3 0.4 1.3 0.8 2.5 1.5 0.7 0.5 1.5 1 3 0.05 2 0.05 0.1 0.1 Insulation resistance: 100 M or more at 500 VDC by megameter Voltage resistance: 1500 VAC, Hz for 1 min.
MGG Indicator light Indicator light Load voltage Auto switch model Lead wire length (m) Pre-wired connector 0.5 (Nil) 3 (L) 5 (Z) Applicable load Type 1 (M) Special function Electrical entry Wiring (Output) DC AC Perpendicular In-line MGC 3-wire (NPN) M9N M9NV 5 V, 12 V IC circuit 3-wire (PNP) MGF M9PV M9P Reed switch Solid state switch Reed switch Solid state switch Lead wire length symbols
Nil S Gripper Applicable Auto Switch Parallel type: 2 fingers Q Lead wire length (m) 0.5 (Nil) Indicator light Auto switch symbol Load voltage Wiring (output) Applicable load Auto switch model Type Electrical entry Electrical entry 5 (Z) 3 (L) DC Gripper bore In-line 10 16 20 25 10 mm 16 mm 20 mm 25 mm Solid state switches D-M9N-746 M9N M9P M9B 3-wire (NPN) 5V 12V IC circuit Relay PLC D-M9P
AC Lead wire length (m) Load voltage DC Auto switch model Special function Electrical entry Indicator light Wiring (Output) Pre-wired connector Applicable load Type In-line Perpendicular 0.5 (Nil) 1 (M) 3 (L) 5 (Z) M9NV M9PV M9BV M9NWV M9PWV M9BWV M9NAV M9PAV M9BAV M9N M9P M9B M9NW M9PW M9BW M9NA M9PA M9BA 5 V, 12 V 3-wire (NPN) 3-wire (PNP) IC circuit Solid state switch 12 V 2-wire 3-wire
Rated voltage Manual override Symbol Nil: Non-locking push type A: Non-locking push type (Manual) E: Push-turn locking type (Manual) DC AC (50/60 Hz) 2(A) 1 100 VAC 2 200 VAC 3 110 VAC [115 VAC] 4 220 VAC [230 VAC] 5 24 VDC 6 12 VDC (P)1 3(R) Electrical entry Light/surge voltage suppressor DC AC Nil Without light/surge voltage suppressor S With surge voltage suppressor *1 DIN terminal
Note 2) In addition, only DC is available with Y. Note 3) For details about external pilot specications, refer to page 481. Combination of external pilot and perfect interface is not possible. Note 4) When multiple symbols are specied, indicate them alphabetically.
VS7-6 How to Order E Q VS7 6 FG S 1 Symbol Number of solenoid Rated voltage Option Port size of sub-plate Connector S D Single Double 1 2 3 4 A02 Without sub-plate N None Indicator light 0 100V AC 200V AC 24V DC 12V DC Connector SV 1 4 FG Side piping FJG W/o connector M Direct manual override 3 8 A03 Side piping SY Thread Z Indicator light with surge voltage suppressor 1 4 B02 Bottom