DESCRIPTION CODE PDE3-S PDE5-S PDE8-S PDE10-S PDE15-S PDE20-S Condensate Y type drain filter 64355FF011 1 1 1 1 1 1 Fan motor 5210135005 1 1 Fan motor 5210135010 1 1 1 1 Fan of the fan motor 521505 1 1 Fan of the fan motor 5215019 1 1 1 1 Fan grid 5225010 1 1 1 1 DMC11 Air Dryer Controller 5620130100 1t 1t 1t 1t 1t 1t Dmc11 probe 5625NNN020 1t 1t 1t 1t 1t 1t Condensate drain solenoid valve
2 w @0 r !0 !9 e i !4 !8 @1 !0 t !3 40 or more MGPWL20 to 63 MGPWA20 to 63 !1!6 MGJ JMGP MGP MGPW MGPW 100 stroke or less MGQ 40 or more !7 MGG MGC MGF Over 100 stroke MGZ MGT Component Parts Component Parts No. Description Material Note Ball bushing Spacer Piston seal Rod seal Gasket A Gasket B No.
4 2 5 A 10 x 8 3/4" x 5/8" 5 1 5 B 19 x 16 1/2" x 3/8" 5 2 6 A 12 x 10 1" x 7/8" SMC 6 1 6 B 25 x 22 3/4" x 5/8" 6 2 19 x 16 : Basic size : With reducer Note) Please select an isometric fitting with the same size as the fitting at the flow sensor.
Refer to the table (1) given below for availability. Refer to page 17-3-65 for ordering a coil only.
cord O.D. 4 to 6.5 78.5 Max .10 71.5 71 Light (DZtype only) 67.5 59 32 17 2 2-4.5 (mounting holes) P 19 35 P Pg.7 2-Rc(PT) 1/8 (ports P) A A A 11 20 26 49 Approx. 300 (lead wire length) 1 P = 19 13.5 L2 5.5 L1 47.5 11 5 n-Rc(PT) 1/8, M5 x 0.8 (port A) 19 35 n-Rc(PT) 1/8 (port R) 47.5 11 R R P = 19 19 L: Dimension table n: Stations n L 1 38 27 2 57 46 3 76 65 4 95 84 5 114 103 6 133 122 7
or by applying current. 4.12-5 Air-hydro Unit SeriesCC How to Order A selection of valve units is available to suit your application. 100 CC S 63 1 1 1 G High cylinder operation speed.
Maximum voltage (with no load): 30 [Vrms] (42.4 [V peak]) or less Maximum current: 1. 8 [A] or less (including when short circuited) 2. Limited by circuit protector (such as fuse) with the following ratings Caution 1. Do not use a lubricator on the supply side of this product, as this can cause a malfunction. ARJ AR425 to 935 2.
*sure dlsplay Accuracy J3% (lull span) Minimum unit [ i l P a : 0 . 0 1 . k a f / c m ' : 0 . 0 1 , b a r : 0 . 0 1 .
Smooth Cylinders Low Speed Cylinders (mm) Rail mounting Auto switch model D-A7lH/A80H D-A73C/A80C D-F7l/J79 D-F7lW/J79W D-F7lV/F7lWV D-F79F D-J79C D-F7BA D-F7BAV D-M9m D-M9mV D-M9mW D-M9mWV D-M9mA D-M9mAV D-A9m D-A9mV D-A7m D-A80 D-F7NT D-A79W A B A B A B A B A B A B Bore size 10 4.5 4.5 0.5 0.5 3 3 3.5 3.5 8.5 8.5 0.5 0.5 16 5 5 1 1 3.5 3.5 4 4 9 9 1 1 Adjust the auto switch after confirming
Pulley cover removal process 1. Remove the thin head screws (TP-M3 x 5, 8 pcs.) fixing the pulley cover using a hexagon wrench. Use a normal hexagon wrench. TP-M3 x 5 TP-M3 x 5 2. Pull out the pulley cover in the direction of the arrow. Pulley cover Motor mounting process 1.
(Part 1: General requirements) ISO 10218-1: Manipulating industrial robots Safety. etc. Caution indicates a hazard with a low level of risk which, if not avoided, could result in minor or moderate injury. Caution: Warning indicates a hazard with a medium level of risk which, if not avoided, could result in death or serious injury.
Calculation: (Example 1) MUB40-15S(T) Basic weight 0.62 kg RQ (Example 2) MUC50-5S(T) Basic weight 1.06 Additional weight (Mounting bracket) 0.40 1.06 + 0.40 = 1.46 kg MU Construction DSpring return -X B 20Data B section MU25 Spring extend B A A section MU25 Component Parts No. q w e r t y u i o !0 !1 !2 !3 !4 !5 !6 !7 !
Calculation: (Example 1) MUB40-15S(T) Basic weight 0.62 kg RQ (Example 2) MUC50-5S(T) Basic weight 1.06 Additional weight (Mounting bracket) 0.40 1.06 + 0.40 = 1.46 kg MU Construction DSpring return -X B 20Data B section MU25 Spring extend B A A section MU25 Component Parts No. q w e r t y u i o !0 !1 !2 !3 !4 !5 !6 !7 !
SlA 7 VlA 8 1 (P) SlA 4 (B) 2 (A) 2 3 (R) VlA VH300 / 400 5 6 VM/VR 4 3 VH 1 8 7 4 (B) 3 (R) 1 (P) 2 (A) 2 VH600 6 5 4 1 7 1 (P) 2 (A) 4 (B) 2 3 (R) Component Parts Material VH200/300/400 Zinc die cast Aluminium die cast VH600 Cast iron Description No.
OUT ~ 1-' ffi q=:J L ~I W ~ Drain (mm) Drain Model Port size A B AMH150 1/8,1/4,3/8 239 80 AMH250 1/4,3/8 252 80 1/2 258 284 AMH350 3/8,1 /2 290 80 (mm) 3/4 Connection Model AMH450 1/2,3/4 1 305 312 80 A 240 B AMH450 AMH550 AMH650 AMH850 3/4B,FF,10K lB,FF,10K 256 AMH550 3/4 ,1 339 80 260 300 349 1 1/2B,FF, 1 OK 2B,FF,10K AMH650 1,11/2 391 80 300 AMH850 11/2,2 540.5 80 380 496.5 SMC CORPORATION
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, "ISE40/50/60 1/8"" NPT VERSION ", INSTRUMENTATION, ISE40/50/60 PRESSURE SWITCH, CB, "ISE40/50/60 1/8"" NPT VERSION ", 0.33992 lb
type Temperature rise 12 (P1) 12 (P1) 10 (P2) PB Power consumption DC Holding Inrush Apparent power AC Air operated 2 (B) 1 (A) 2 (B) 1 (A) 2 (B) 1 (A) 10 (P2) Manual override VNA11 VNA12 12 (P1) 12 (P1) External pilot solenoid 1 (A) 2 (B) 2 (B) 1 (A) 17-4-7 4 Series VNA Port size 6A, 8A, 10A Applicable cable O.D. 6 to 8 (D.T) 125 (Conduit terminal: T DIN terminal: D) 108.2 (Grommet terminal
4-7-17 2 Series VT325 Flow Characteristics/Weight Flow characteristics 1 2 (P A) 2 3 (A R) 3 2 (R A) 2 1 (A P) Weight Valve model Grommet Port size C [dm 3/(sbar)] b Cv C [dm 3/(sbar)] b Cv C [dm 3/(sbar)] b Cv C [dm 3/(sbar)] b Cv VT325 VT325V (Vacuum spec. type) VT325 VT325V (Vacuum spec. type) 0.55 kg (For AC) 0.60 kg (For DC) Note) Values for a single valve unit.
2, 3 port Note 1) 10-V114(A) and 10-V124(A) cannot be mounted on the same manifold.
2 w y r u e !2 t i q o !0 !1 i q o !0 !1 Component Parts No. Description Body A Handle Body B Needle Seat ring Needle guide Material Note No.