N 2-J 2-11 2-M6 x 1.0 M M L 6.2 9.5 SMC SMC 2-K 2-7 Side support A part no.: MF-S32A Side support B part no.: MF-S32B Support bracket A part no.: MY-SA Support bracket B part no.: MY-SB Part No.
Fittings & Tubing Air Cylinders Rotary Actuators S ZZ SS 20 10 9 2 x 4.3 through Z 2 x 8 counterbore depth 4.4 18 5 30 1 M6 x 1.0 x 5 L (Hexagon socket set screw) 450.2 450.2 48 56 25 58 6.3 5 2 x M4 x 0.7 thread depth 6 1 M4 x 0.7 x 14.5 L and M4 x 0.7 (Hexagon bolt) (Hexagon nut) 9 M5 x 0.8 x 10 L (Hexagon socket head cap screw) 2 x M5 x 0.8 (Through-hole) (Z) 2 x M5 x 0.8 thread depth
Power supply voltage is 200VAC single phase Trouble OFF ON RA MC Emergency stop MC SK (Note 6) Driver Servo motor Servo amplifier (Note 7) Controller CNP1 MC NFB 1-phase 200 to 230VAC L1 CNP3 (Note 5) U L2 U Motor V L3 V [1] M W N W P1 (Note 1) P2 PE CNP2 P [2] (Note 2) C [3] D Encoder CN2 (Note 3) Encoder cable L11 L21 [1] Provide specified power supply to input terminals L1 and L2. [2]
N None 1 2 n T 7 Digital Gap Checker With Control Unit ISA3 Series 3-Color Display RoHS How to Order G C N M B 2 ISA3 L 1 Rated distance range F 0.01 to 0.03 mm G 0.02 to 0.15 mm H 0.05 to 0.30 mm 2 port solenoid valve Rated voltage Piping specifications Output specifications Nil 24 VDC 1 *11 100 VAC 2 *11 110 VAC *11: Made to Order N NPN output P PNP output Supply side Detection side Unit
NEW ZEALAND SMC Pneumatics (N.2.) Ltd.
CXS25-80-XB19 80 176 152 CXS25-90-XB19 90 186 162 CXS25-100-XB19 100 196 172 CXS32--XB19 36 1 38 S 18 12 ZZ 30 Z SS 2-6 x 32l AW (spring pin) 26 9 2-6.9 through 2-11 counter bore depth 6.3 98 96 1 6.3 76 5 75 0.2 44 8 4.1 M8 x 1.25 x 23l and M8 x 1.25 (hexagon bolt) (hexagon nut) 2-M6 x 1 (through) 18 2-M5 x 0.8 Thread depth 8 30 (Z) 8-M5 x 0.8 thread depth 7.5 (same on reverse side) 4-Rc
bytes up to 56 bytes 2 bytes 2 bytes Depends on 01-FF Function function LRC CR, LF code B) Response (Card Motor controller upper-level device such as PLC) Normal response code Note 2) Data Check End Start code ID Note 1) Function sum code 1 byte 2 bytes 2 bytes n byte 2 bytes 2 bytes Depends on 01-FF Function function LRC CR,LF code Irregular response Start code ID Note 1) Error function
Action Double acting Fluid Air Operating pressure 0.25 to 0.6 MPa Ambient and fluid temperature 10 to 60C (No freezing) Holding force (Workpiece thickness: 0.6 mm) Symbol Holding force Model 1 80 N MHM-A3201-1-X6400 2 50 N MHM-A3201-2-X6400 3 30 N MHM-A3201-3-X6400 MHM-32D1-X6400 80 N MHM-32D2-X6400 50 N MHM-32D3-X6400 30 N Residual holding force 0.3 N or less Lubrication Non-lube Weight
Ta 10 STa(S 10) = & I Ta (Nm) I: & 2 = & (rad/s2) 2 t 5.2 5.3 22 5.4 P A F 1 1 = (1) P A F 2 2 = (2) 2 1 D 4 A = (3) ) d D ( 4 A 2 2 2 = (4) F=[N] F=[N] = A=[mm] A=[mm] D=[mm] d=[mm] P=[MPa] 5.6 () 5.7 () 5.5 23 6. 6. 6. 6. ,, , ,, 6-1. 6.1 (m) DC AC 0.5 3 5 (L) (Z) (N) 3 (NPN) F7NV F79 3 (PNP) 5V,12V F7PV F7P IC F7BV J79 2 12V J79C 24V 3 (NPN) F7NWV F79W PLC 3 (PNP) 5V,
Formula (2) Formula P 0.1013 Qc = Qc x n x Number of actuators x Reserve factor QCP = 2 x a x l x x 10-6. (3) QC = QCR + QCP. (4) Qc = Compressor discharge flow rate n = Actuator reciprocations per minute QCR = Air consumption of rotary actuator [l (ANR)] Internal cross section of tubing and steel piping QCP = Air consumption of tubing or piping [l (ANR)] V = Internal volume of rotary actuator
Filter Regulator AW30, 40 Related Equipment How to Order Integration of a filter and regulator allows simple wiring. 03 BE 30 1N AW F Optional specifications Filter regulator Applicable models AW30, 40 AW30, 40 AW30, 40 AW30, 40 AW30, 40 AW30, 40 AW30, 40 AW30, 40 AW30, 40 Symbol 1 2 6 8 J N R W Z Contents 0.02 to 0.2MPa setting Metal bowl Nylon bowl Metal bowl with level gauge Drain guide
(different sides) 25 2 pcs. (same side) 70 D-Y7BAL 1pc., 2 pcs.
Switch mounting screw: 2 pcs. (lvl3x0.sx16L) Switch mounting bracket scre\, 2 pcs. (M3x0.5x 1aL) Switch mounling nut: 1 pc. Sp ng washer: 2 pcs. Nomihal diameleri 3mm 41-140.F (5-60.C) Non-lube Not available Male thfead (srd.)
With adjusting bolt Piston speed (Non-lube) 30 to 500 mm/s With shock absorber Cushion With shock absorber (Option) Stroke adjustable range Standard stroke: 2 mm CX2N10 CX215 CX225 CX2N10 CX215 CX225 9.8 N Max. load mass (1) 29.4 N 58.8 N 0.1 Non-rotating accuracy Except piston rod deflection ( ) 0.04 0.02 Straight knock pin (2 pcs.), Adjusting bolt (-X138)(2) Accessory (Option) Shock absorber
IC circuit 5V A96V A96 3 wire (NPN) F9NV F9N 3 wire (PNP) F9PV F9P 2 wire F9BV F9B Relay PLC Yes Grommet 24V 12V 3 wire (NPN) F9NWV F9NW Diagnostic indication (2 color indicator) 3 wire (PNP) F9PWV F9PW F9BWV F9BW 2 wire Lead wire length symbol 0.5m . (Example) A93 3m . L (Example) A93L 5m .
-10AS G46-2-02 G36-2-01 G46-2-02 G46-2-02 G46-2-02 0.2MPa Note 3) GC3-2AS GC3-2AS GC3-2AS GC3-2AS GC3-2AS Note 1) Assembly includes a bracket and set nuts.
) (7)(8) 5 - No.ZQ-OM01401-B ZQ 05 1U A-K15LO B-VA M W-3 3-N (1) (2) (3) (4) (5) (6) (7)(8) (9) (1) (6) 05 0.5 07 0.7 W (2m) 10 1.0 (7) (V ) (8) (P ) (2) 1U 0 (M5x0.8) 3M 1 3.2 () 0 (M5x0.8) 2 4 () 2 4 () (3) 3 6 () 3 6 () 4 3.2 () 5 4 () B 5 4 () 1) (9) (4) ( [kPa] VA -100 to 100 NPN1 + VB PNP1 + N 1) ZFC (5) 2) M SI (kPa) 2) (99 10 ) ZZQ108A-B S C-A (1) (2
Programmable logic controller 2m max. ( Note 8) FX3UMT/ES (Note 13) Diver S/S Servo amplifier 24V 0V (Note 7) (Note 7) (Note 2) L CN1 CN1 24VDC PLC power (Note 4, 1 0 ) 1 DICOM 9 ALM supply RA1 Trouble (Note 6) N OPC 2 (Note 10, 12) 12 MBR Electromagnetic brake interlock RA2 13 DOCOM Y000 PP 23 23 Note1) COM1 (Note 14) 25 Note1) Y010 NP 25 10m max.
D. 2.9 Standard 2m Cord extension (Individual metal piping) Max. 100m 4 M5 X 0.5 Tightening nut Toothed lock washer E2E-X2D1-N (RSH50/63/80) 30 7 26 13 Indicator light Tightening nut M8 X 1 *Polyvinyl chloride round cord 3.5 (18/0.12) 2 wire Standard 2m Cord extension (Individual metal piping) Max. 200m Toothed lock washer 4 Output Circuit E2E-X1C1/3-wire E2E-X2D1-N/2-wire Brown (White) Load