Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: SI Unit Only, Fixed Unit: kPa, MPa, Piping Specification: R1/8, Lead Wire: Lead Wire w/Connector, 5-core, 2m Lead Wire w/Waterproof Cover, Bracket: None, Operation Manual: w/o Operation Manual, w/o Calibration Certificate

Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: SI Unit Only, Fixed Unit: kPa, MPa, Piping Specification: R1/8, Lead Wire: Lead Wire w/Connector, 5-core, 2m Lead Wire w/Waterproof Cover, Bracket: None, Operation Manual: Operation Manual, Calibration Certificate

Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: SI Unit Only, Fixed Unit: kPa, MPa, Piping Specification: NPT1/8, Lead Wire: Lead Wire w/Connector, 5-core, 2m Lead Wire w/Waterproof Cover, Bracket: B [Panel Mount Adapter, (ZS-46-B)], Operation Manual: -

Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: SI Unit Only, Fixed Unit: kPa, MPa, Piping Specification: R1/8, Lead Wire: Lead Wire w/Connector, 5-core, 2m Lead Wire w/Waterproof Cover, Bracket: -, Operation Manual: -

Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: SI Unit Only, Fixed Unit: kPa, MPa, Piping Specification: R1/8, Lead Wire: Lead Wire w/Connector, 5-core, 2m Lead Wire w/Waterproof Cover, Bracket: A2 [Bracket B, Horizontal Mounting (ZS-46-A2)], Operation Manual: -

Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: SI Unit Only, Fixed Unit: kPa, MPa, Piping Specification: R1/8, Lead Wire: w/o Lead Wire, Bracket: None, Operation Manual: w/o Operation Manual, w/o Calibration Certificate

Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: SI Unit Only, Fixed Unit: kPa, MPa, Piping Specification: NPT1/8, Lead Wire: Lead Wire w/Connector, 5-core, 2m Lead Wire w/Waterproof Cover, Bracket: A2 [Bracket B, Horizontal Mounting (ZS-46-A2)], Operation Manual: -

Rated Vacuum Range: -100.0 to 100.0 kPa, Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: SI Unit Only, Piping Specification: NPT1/8, Lead Wire: Lead Wire w/Connector, 5-core, 2m Lead Wire w/Waterproof Cover, Bracket: -, Operation Manual: -

Rated Vacuum Range: -100.0 to 100.0 kPa, Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: SI Unit Only, Piping Specification: R1/8, Lead Wire: Lead Wire w/Connector, 5-core, 2m Lead Wire w/Waterproof Cover, Bracket: -, Operation Manual: -

Rated Vacuum Range: -100.0 to 100.0 kPa, Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: SI Unit Only, Piping Specification: R1/8, Lead Wire: w/o Lead Wire, Bracket: A2 [Bracket B (ZS-46-A2)], Operation Manual: -

Also, it should be noted that the discharge rate will be less than the normal condition. 2) Air consumption Air consumption Caution Air consumption L/min[ANR] 0 5 10 15 20 25 30 35 40 45 L/min[ANR] -If the compressor output is selected based on air consumption, 0.75kW per 100L/min (ANR) is the guide. 1 2 3 4 5 6 7 8 9 10 Hz Cycle Hz 15 3) Viscosity characteristics With reference to the

AL Dimensions DXT334-X72-04R-04U L side U side D side Exhaust port R side Rc 1/2 supply port (L side) 2-Rc 1/2, Output port 14-9-23

Lead Wire: G [Lead Wire (2m) w/Connector (w/Connector Cover)], Check Valve: None, Fitting (V Port): 0 [w/o Fitting (M5 x 0.8)], Fitting (P Port): 0 [w/o Fitting (M5 x 0.8)]

Series: 3 (10-SY3000), Actuation: 1 (2 Position, Single), Coil Specification: None, Voltage: 5 (24 VDC), Electrical Entry: L [L Plug Connector, w/Lead Wire, (300mm)], Light/Surge Voltage Suppressor: Z (with Light/Surge Voltage Suppressor), Manual Override: Non-Locking Push Type, A, B Port Size: M5 (M5 x 0.8), Thread: Rc, Bracket: F1 (w/Foot Bracket, 2 Position Single Only)

Actuation: 1 (Normally Closed), Piping: 4M (Base Mounted), Coil Specification: Standard, Voltage: 5 (24 VDC), Electrical Entry: L (L Plug Connector, w/Lead Wire Length 300mm), Light/Surge Voltage Suppressor: Z (w/Light/Surge Voltage Suppressor), Manual Override: D (Push-turn Locking Slotted Type), Port Size: M5 (M5 Port w/Sub-plate)

Actuation: 1 (Normally Closed), Piping: 4M (Base Mounted), Coil Specification: T (w/Power Saving Circuit, 24, 12 VDC Only), Voltage: 5 (24 VDC), Electrical Entry: L (L Plug Connector, w/Lead Wire Length 300mm), Light/Surge Voltage Suppressor: Z (w/Light/Surge Voltage Suppressor), Manual Override: Non-locking Push Type, Port Size: M5 (M5 Port w/Sub-plate)

Actuation: 1 (Normally Closed), Piping: 4M (Base Mounted), Coil Specification: Standard, Voltage: 5 (24 VDC), Electrical Entry: L (L Plug Connector, w/Lead Wire Length 300mm), Light/Surge Voltage Suppressor: Z (w/Light/Surge Voltage Suppressor), Manual Override: Non-locking Push Type, Port Size: M5 (M5 Port w/Sub-plate)

Actuation: 1 (Normally Closed), Piping: 2M (Body Ported), Coil Specification: Standard, Voltage: 6 (12 VDC), Electrical Entry: L (L Plug Connector, w/Lead Wire Length 300mm), Light/Surge Voltage Suppressor: Z (w/Light/Surge Voltage Suppressor), Manual Override: D (Push-turn Locking Slotted Type), Port Size: M5 (M5 Port w/Sub-plate)

Function: 2 (2 Position Double), Piping: 4 (Base Mounted 5 Port), Exhaust: 0 (Individual), Specifications: Standard, Voltage: 5 (24VDC), Lead Wire: L (L Plug Connector w/Lead Wire 0.3m), Surge Suppressor: None, Manual Override: Non-locking Push Type, Port Size: M5 (Base Mounted M5 w/Sub-plate)

Function: 1 (2 Position Single), Piping: 4 (Base Mounted 5 Port), Exhaust: 0 (Individual), Specifications: Standard, Voltage: V (6VDC), Lead Wire: L (L Plug Connector w/Lead Wire 0.3m), Surge Suppressor: None, Manual Override: Non-locking Push Type, Port Size: M5 (Base Mounted M5 w/Sub-plate)