Type of Actuation: 1 (2 Position Single), Manifold Type: 40 (Base Ported), Pilot: R (External Pilot), Specifications: Standard, Voltage: 1 (100VAC 50/60HZ), Electrical Entry: DO (DIN Connector w/o Connector), Lead Wire Length: None, Surge Suppressor: None, Manual Override: Non-locking Push Style, A, B Port Size: 03 (Body Ported/Base Mounted 3/8), Thread: T (NPTF)
Type of Actuation: 1 (2 Position Single), Manifold Type: 40 (Base Ported), Pilot: Internal Pilot, Specifications: Standard, Voltage: 5 (24VDC), Electrical Entry: W (M8 Connector w/ Connector), Lead Wire Length: 1 (300mm), Surge Suppressor: Z (Light & Surge Suppressor), Manual Override: Non-locking Push Style, A, B Port Size: 03 (Body Ported/Base Mounted 3/8), Thread: N (NPT)
Type of Actuation: 1 (2 Position Single), Manifold Type: 40 (Base Ported), Pilot: Internal Pilot, Specifications: Standard, Voltage: 1 (100VAC 50/60HZ), Electrical Entry: D (DIN Connector), Lead Wire Length: None, Surge Suppressor: Z (Light & Surge Suppressor), Manual Override: Non-locking Push Style, A, B Port Size: 03 (Body Ported/Base Mounted 3/8)
Function: 1 (2 Position Single), Body Option: 1 (Non Plug-in Centralized Lead Wire Entry), Option: 0 (Standard), Pilot: Internal Pilot, Voltage: 3 (110VAC 50/60HZ), Lead Wire: D (DIN Connector), Surge Suppressor: None, Manual Override: Non-locking Push Style (Flush), Piping: Side, Port Size: 03 (Sub-plate 3/8), Thread: T (NPTF)
Function: 1 (2 Position Single), Body Option: 1 (Non Plug-in Centralized Lead Wire Entry), Option: 0 (Standard), Pilot: Internal Pilot, Voltage: 3 (110VAC 50/60HZ), Lead Wire: D (DIN Connector), Surge Suppressor: Z (Light & Surge Suppressor), Manual Override: A (Non-locking Push Extended Style), Piping: Side, Port Size: 03 (Sub-plate 3/8), Thread: T (NPTF)
Function: 1 (2 Position Single), Body Option: 1 (Non Plug-in Centralized Lead Wire Entry), Option: 0 (Standard), Pilot: Internal Pilot, Voltage: 3 (110VAC 50/60HZ), Lead Wire: E (Grommet Terminal), Surge Suppressor: None, Manual Override: Non-locking Push Style (Flush), Piping: Side, Port Size: 03 (Sub-plate 3/8), Thread: T (NPTF)
Function: 1 (2 Position Single), Body Option: 1 (Non Plug-in Centralized Lead Wire Entry), Option: 0 (Standard), Pilot: Internal Pilot, Voltage: 5 (24VDC), Lead Wire: D (DIN Connector), Surge Suppressor: None, Manual Override: Non-locking Push Style (Flush), Piping: Side, Port Size: 03 (Sub-plate 3/8), Thread: T (NPTF)
Function: 1 (2 Position Single), Body Option: 1 (Non Plug-in Centralized Lead Wire Entry), Option: 0 (Standard), Pilot: R (External Pilot), Voltage: 5 (24VDC), Lead Wire: D (DIN Connector), Surge Suppressor: Z (Light & Surge Suppressor), Manual Override: Non-locking Push Style (Flush), Piping: Side, Port Size: 03 (Sub-plate 3/8), Thread: T (NPTF)
Function: 3 (3 Position Closed Center), Body Option: 1 (Non Plug-in Centralized Lead Wire Entry), Option: 0 (Standard), Pilot: Internal Pilot, Voltage: 1 (100VAC 50/60HZ), Lead Wire: D (DIN Connector), Surge Suppressor: None, Manual Override: Non-locking Push Style (Flush), Piping: Side, Port Size: 03 (Sub-plate 3/8), Thread: T (NPTF)
Function: 1 (2 Position Single), Body Option: 1 (Non Plug-in Centralized Lead Wire Entry), Option: 0 (Standard), Pilot: Internal Pilot, Voltage: 3 (110VAC 50/60HZ), Lead Wire: D (DIN Connector), Surge Suppressor: None, Manual Override: Non-locking Push Style (Flush), Piping: Side, Port Size: 03 (Sub-plate 3/8)
Function: 2 (2 Position Double), Body Option: 1 (Non Plug-in Centralized Lead Wire Entry), Option: 0 (Standard), Pilot: Internal Pilot, Voltage: 1 (100VAC 50/60HZ), Lead Wire: D (DIN Connector), Surge Suppressor: Z (Light & Surge Suppressor), Manual Override: Non-locking Push Style (Flush), Piping: Side, Port Size: 03 (Sub-plate 3/8)
Function: 1 (2 Position Single), Body Option: 1 (Non Plug-in Centralized Lead Wire Entry), Option: 0 (Standard), Pilot: Internal Pilot, Voltage: 5 (24VDC), Lead Wire: D (DIN Connector), Surge Suppressor: None, Manual Override: Non-locking Push Style (Flush), Piping: Side, Port Size: 03 (Sub-plate 3/8)
Function: 1 (2 Position Single), Body Option: 1 (Non Plug-in Centralized Lead Wire Entry), Option: 0 (Standard), Pilot: Internal Pilot, Voltage: 6 (12VDC), Lead Wire: D (DIN Connector), Surge Suppressor: Z (Light & Surge Suppressor), Manual Override: Non-locking Push Style (Flush), Piping: Side, Port Size: 03 (Sub-plate 3/8), Thread: T (NPTF)
Function: 1 (2 Position Single), Body Option: 4 (Non plug-in, Individual Electrical Entry), Option: 1 (Direct Manual Override), Pilot: Internal Pilot, Voltage: 5 (24VDC), Lead Wire: E (Grommet Terminal), Surge Suppressor: None, Manual Override: B (Locking Slotted Style), Piping: Side, Port Size: 03 (Sub-plate 3/8)
Type of Actuation: 1 (2 Position Single), Manifold Type: 40 (Base Mounted), Pilot: Internal Pilot, Specifications: Standard, Voltage: 1 (100VAC 50/60HZ), Electrical Entry: D (DIN Terminal w/Connector), Lead Wire Length: None, Surge Suppressor: None, Manual Override: Non-locking Push Style, Port Size: 03 (Base Mounted w/Sub-plate 3/8)
Type of Actuation: 1 (2 Position Single), Manifold Type: 40 (Base Mounted), Pilot: Internal Pilot, Specifications: Standard, Voltage: 1 (100VAC 50/60HZ), Electrical Entry: D (DIN Terminal w/Connector), Lead Wire Length: None, Surge Suppressor: Z (Light & Surge Suppressor), Manual Override: Non-locking Push Style, Port Size: 03 (Base Mounted w/Sub-plate 3/8)
Type of Actuation: 1 (2 Position Single), Manifold Type: 40 (Base Mounted), Pilot: Internal Pilot, Specifications: Standard, Voltage: 1 (100VAC 50/60HZ), Electrical Entry: D (DIN Terminal w/Connector), Lead Wire Length: None, Surge Suppressor: Z (Light & Surge Suppressor), Manual Override: Non-locking Push Style, Port Size: 03 (Base Mounted w/Sub-plate 3/8), Thread: N (NPT)
Type of Actuation: 1 (2 Position Single), Manifold Type: 40 (Base Mounted), Pilot: Internal Pilot, Specifications: Standard, Voltage: 1 (100VAC 50/60HZ), Electrical Entry: DO (DIN Connector w/o Connector), Lead Wire Length: None, Surge Suppressor: None, Manual Override: Non-locking Push Style, Port Size: 03 (Base Mounted w/Sub-plate 3/8)
Type of Actuation: 1 (2 Position Single), Manifold Type: 40 (Base Mounted), Pilot: Internal Pilot, Specifications: Standard, Voltage: 1 (100VAC 50/60HZ), Electrical Entry: L (L Plug Connector w/Lead Wire 0.3m), Lead Wire Length: None, Surge Suppressor: Z (Light & Surge Suppressor), Manual Override: Non-locking Push Style, Port Size: 03 (Base Mounted w/Sub-plate 3/8), Thread: T (NPTF)
Type of Actuation: 1 (2 Position Single), Manifold Type: 40 (Base Mounted), Pilot: Internal Pilot, Specifications: Standard, Voltage: 1 (100VAC 50/60HZ), Electrical Entry: D (DIN Terminal w/Connector), Lead Wire Length: None, Surge Suppressor: Z (Light & Surge Suppressor), Manual Override: E (Push-turn Locking Lever Style), Port Size: 03 (Base Mounted w/Sub-plate 3/8)