SMC Corporation of America
Elite Part Number Search
Search Results "RZQL50TN-50-20"

The settings of the master pressur, SWITCH, INSTRUMENTATION, ISE40/50/60 PRESSURE SWITCH, 1X, ISE40/50/60 OTHER SZ (OTHER), .29312 lb, ModelRated pressure rangeDisplay/Set pressure rangeWithstand pressureDisplay/Minimum unit settingApplicable fluidPower supply voltageCurrent consumptionSwitch output--Repeat accuracyHysteresisAnalog outputAuto-shift inputDisplayDisplay accuracyIndicator

Please contact us for the latest version.sales@ocaire.com, SWITCH, VACUUM SERIES, ZSE40/50/60 VACUUM SWITCH, 1C, ZSE40/50/60 OTHER SIZE RATING, .28660 lb, ModelRated pressure rangeDisplay/Set pressure rangeWithstand pressureDisplay/Minimum unit settingApplicable fluidPower supply voltageCurrent consumptionSwitch output--Repeat accuracyHysteresisAnalog outputAuto-shift inputDisplayDisplay

The settings of the master pressur, SWITCH, INSTRUMENTATION, ISE40/50/60 PRESSURE SWITCH, 1X, ISE40/50/60 OTHER SZ (OTHER), .25633 lb, ModelRated pressure rangeDisplay/Set pressure rangeWithstand pressureDisplay/Minimum unit settingApplicable fluidPower supply voltageCurrent consumptionSwitch output--Repeat accuracyHysteresisAnalog outputAuto-shift inputDisplayDisplay accuracyIndicator

The settings of the master pressur, SWITCH, INSTRUMENTATION, ISE40/50/60 PRESSURE SWITCH, CB, ISE40/50/60 1/8 NPT VERSION, .17416 lb, ModelRated pressure rangeDisplay/Set pressure rangeWithstand pressureDisplay/Minimum unit settingApplicable fluidPower supply voltageCurrent consumptionSwitch output--Repeat accuracyHysteresisAnalog outputAuto-shift inputDisplayDisplay accuracyIndicator

The settings of the master pressur, SWITCH, INSTRUMENTATION, ISE40/50/60 PRESSURE SWITCH, CB, ISE40/50/60 1/8 NPT VERSION, .17416 lb, ModelRated pressure rangeDisplay/Set pressure rangeWithstand pressureDisplay/Minimum unit settingApplicable fluidPower supply voltageCurrent consumptionSwitch output--Repeat accuracyHysteresisAnalog outputAuto-shift inputDisplayDisplay accuracyIndicator

Settable range : 10...988 (1.0 kPa...98.8 kPa) Combination conditions with other parameters : 10 H1 P1-1 (50) ... ... ... ... ... 16 2 R/W 0x0032 Vacuum confirmation hysteresis (H1) of CH15 (50) 3.4.3. Pressure P2 (Index 66) Table 3-11.

V114-5LU Fluid Air Ambient and operating fluid temperature(oC) -10 to 50 (No freezing) Response time [ms] ON5 or less OFF4 or less Minimum operation frequency [Hz] 20 Lubrication Not required Mounting orientation Free Impact resistance/Vibration resistance (m/s2) 15030 Enclosure rating Dustproof Model No.

V114-5LU Fluid Air Ambient and operating fluid temperature(oC) -10 to 50 (No freezing) Response time [ms] ON5 or less OFF4 or less Minimum operation frequency [Hz] 20 Lubrication No Mounting orientation Free Impact resistance/Vibration resistance (m/s2) 15030 Enclosure rating Dustproof Model No.

V114-5LU Fluid Air Ambient and operating fluid temperature(oC) -10 to 50 (No freezing) Response time [ms] ON5 or less OFF4 or less Minimum operation frequency [Hz] 20 Lubrication Non-lube Mounting orientation Free Impact resistance/Vibration resistance (m/s2) 15030 Enclosure rating Dustproof Model No.

3/8, 1/2 70 147.1 25.5 35.5 38.4 75 35.5 50 52 30 8.5 12.5 88 2.3 39 186.9 AFD40-06-D 3/4 75 149.1 27 35.5 38.4 75 35.5 50 52 34 8.5 12.5 88 2.3 43 188.9 Semi-standard specifications PC/PA bowl Metal bowl with Metal bowl level gauge With element Model With With With With With With service indicator barb drain drain drain drain drain fitting guide cock guide cock guide B B B B B B A C1 AFD20

The settings of the master pressur, SWITCH, INSTRUMENTATION, ISE40/50/60 PRESSURE SWITCH, CA, ISE40/50/60 1/8 PT VERSION, .47265 lb, ModelRated pressure rangeDisplay/Set pressure rangeWithstand pressureDisplay/Minimum unit settingApplicable fluidPower supply voltageCurrent consumptionSwitch output--Repeat accuracyHysteresisAnalog outputAuto-shift inputDisplayDisplay accuracyIndicator

Please contact us for the latest version.sales@ocaire.com, SWITCH, INSTRUMENTATION, ISE40/50/60 PRESSURE SWITCH, CA, ISE40/50/60 1/8 PT VERSION, .38605 lb, ModelRated pressure rangeDisplay/Set pressure rangeWithstand pressureDisplay/Minimum unit settingApplicable fluidPower supply voltageCurrent consumptionSwitch output--Repeat accuracyHysteresisAnalog outputAuto-shift inputDisplayDisplay

Please contact us for the latest version.sales@ocaire.com, SWITCH ASSEMBLY, INSTRUMENTATION, ISE40/50/60 PRESSURE SWITCH, CA, ISE40/50/60 1/8 PT VERSION, .38605 lb, ModelRated pressure rangeDisplay/Set pressure rangeWithstand pressureDisplay/Minimum unit settingApplicable fluidPower supply voltageCurrent consumptionSwitch output--Repeat accuracyHysteresisAnalog outputAuto-shift inputDisplayDisplay

The settings of the master pressur, SWITCH ASSEMBLY, INSTRUMENTATION, ISE40/50/60 PRESSURE SWITCH, CA, ISE40/50/60 1/8 PT VERSION, .38475 lb, ModelRated pressure rangeDisplay/Set pressure rangeWithstand pressureDisplay/Minimum unit settingApplicable fluidPower supply voltageCurrent consumptionSwitch output--Repeat accuracyHysteresisAnalog outputAuto-shift inputDisplayDisplay accuracyIndicator

The settings of the master pressur, SWITCH ASSEMBLY, INSTRUMENTATION, ISE40/50/60 PRESSURE SWITCH, CA, ISE40/50/60 1/8 PT VERSION, .34462 lb, ModelRated pressure rangeDisplay/Set pressure rangeWithstand pressureDisplay/Minimum unit settingApplicable fluidPower supply voltageCurrent consumptionSwitch output--Repeat accuracyHysteresisAnalog outputAuto-shift inputDisplayDisplay accuracyIndicator

Please contact us for the latest version.sales@ocaire.com, SWITCH ASSEMBLY, INSTRUMENTATION, ISE40/50/60 PRESSURE SWITCH, CA, ISE40/50/60 1/8 PT VERSION, .33069 lb, ModelRated pressure rangeDisplay/Set pressure rangeWithstand pressureDisplay/Minimum unit settingApplicable fluidPower supply voltageCurrent consumptionSwitch output--Repeat accuracyHysteresisAnalog outputAuto-shift inputDisplayDisplay

Please contact us for the latest version.sales@ocaire.com, SWITCH, INSTRUMENTATION, ISE40/50/60 PRESSURE SWITCH, CA, ISE40/50/60 1/8 PT VERSION, .34277 lb, ModelRated pressure rangeDisplay/Set pressure rangeWithstand pressureDisplay/Minimum unit settingApplicable fluidPower supply voltageCurrent consumptionSwitch output--Repeat accuracyHysteresisAnalog outputAuto-shift inputDisplayDisplay

The settings of the master pressur, SWITCH ASSEMBLY, INSTRUMENTATION, ISE40/50/60 PRESSURE SWITCH, CA, ISE40/50/60 1/8 PT VERSION, .34277 lb, ModelRated pressure rangeDisplay/Set pressure rangeWithstand pressureDisplay/Minimum unit settingApplicable fluidPower supply voltageCurrent consumptionSwitch output--Repeat accuracyHysteresisAnalog outputAuto-shift inputDisplayDisplay accuracyIndicator

The settings of the master pressur, SWITCH ASSEMBLY, INSTRUMENTATION, ISE40/50/60 PRESSURE SWITCH, CA, ISE40/50/60 1/8 PT VERSION, .34072 lb, ModelRated pressure rangeDisplay/Set pressure rangeWithstand pressureDisplay/Minimum unit settingApplicable fluidPower supply voltageCurrent consumptionSwitch output--Repeat accuracyHysteresisAnalog outputAuto-shift inputDisplayDisplay accuracyIndicator

The settings of the master pressur, SWITCH ASSEMBLY, INSTRUMENTATION, ISE40/50/60 PRESSURE SWITCH, CA, ISE40/50/60 1/8 PT VERSION, .33743 lb, ModelRated pressure rangeDisplay/Set pressure rangeWithstand pressureDisplay/Minimum unit settingApplicable fluidPower supply voltageCurrent consumptionSwitch output--Repeat accuracyHysteresisAnalog outputAuto-shift inputDisplayDisplay accuracyIndicator