SMC Corporation of America
Elite Part Number Search
Search Results "LVM11-5C-1-6-Q"

Area: -, Stations: 6 Stations, AB Port: 3/8, Left, Control: None, PR Port: 3/8, Both Sides, Silencer: -, Voltage: -, Q: -, Area: North America

Area: -, Stations: 6 Stations, AB Port: 3/8, Left, Control: None, PR Port: 3/8, Bottom, Silencer: -, Voltage: -, Q: -, Area: North America

Area: -, Stations: 6 Stations, AB Port: 3/8, Right, Control: None, PR Port: 3/8, Both Sides, Silencer: -, Voltage: -, Q: -, Area: North America

Area: -, Stations: 6 Stations, AB Port: 3/8, Right, Control: None, PR Port: 3/8, Bottom, Silencer: -, Voltage: -, Q: -, Area: North America

Area: -, Stations: 6 Stations, AB Port: 3/8, Bottom, Control: F [Filter w/Auto Drain, Regulator (Air Release Valve-Blank)], PR Port: 3/8, Both Sides, Silencer: -, Voltage: -, Q: -, Area: North America

Area: -, Stations: 6 Stations, AB Port: 3/8, Bottom, Control: None, PR Port: 3/8, Bottom, Silencer: -, Voltage: -, Q: -, Area: North America

OUTLET INLET Mounting hole Top view (Mounting hole on bottom) Porting Symbols OUTLET (Downstream) INLET (Upstream) 2PW 2PWA 2PWC q q q w 2 PORTS w w 3PWD 3PWE 3PWG 3 PORTS q q q e e e w w w 4PWM q e r 4 PORTS w 1114 A

Red ON Short circuit at L+ or C/Q LED 1, 2, 3, 4 for I/Q (EX600-LAB1) Function LED status Description End plate bracket (EX600-ZMA2) OFF Input OFF I/Q Orange ON Input ON CAUTION indicates a hazard with a low level of risk which, if not avoided, could result in minor or moderate injury.

Please contact us for the latest version.sales@ocaire.com, VALVE, VALVE, LVM CHEMICAL VALVE, 2 PORT, 2A, LVM BODY PORT, NO SIZE RATING, 1.74150 lb, ModelValve constructionValve typeNumber of portsFluid Note 1)Operating pressure rangeOrifice diameterResponse timeLeakageProof pressure Note 2)Ambient temperatureFluid temperatureVolume of valve chamberMounting orientationEnclosureWeightRated

Service life (based on SMC test conditions) is 10 million cycles or more.Orifice diameter of LVM11: 1.5mm, Orifice diameter of LVM10: 1.4mm , Available with power-saving circuit , 2 port N.C. or N.O. types; 3 port Universal type , Diaphragm choice of EPDM, FKM or Kalrez?

Real-time switch output Unit switching Hysteresis mode ON For Air YES OFF P-1 P-2 Display Real-time flow rate l/min Accumulated flow l Real-time flow rate "P" Window comparator mode H : Hysteresis CFM x 10-2 x CFM x 10-1 ft3 x 10-1 H H CFM = ft3/min ON High Flow Rate Type (For Air) NO OFF P-1 P-2 Display Real-time flow rate l/min Accumulated flow l, m3, m3 x 103 Real-time flow rate OUT1

Symbol: 11 (Body Ported), Voltage: 6 (12 VDC), Wetted Part Material: B (Plate: PEEK; Diaphragm: FKM)

Symbol: 11 (Body Ported), Voltage: 5 (24 VDC), Wetted Part Material: A (Plate: PEEK; Diaphragm: EPDM)

Symbol: 11 (Body Ported), Voltage: 5 (24 VDC), Wetted Part Material: A (Plate: PEEK; Diaphragm: EPDM), Reverse Mounting Prevention Pin: None, Bracket: 1 (Bracket)

Symbol: 11 (Body Ported), Voltage: 5 (24 VDC), Wetted Part Material: B (Plate: PEEK; Diaphragm: FKM), Reverse Mounting Prevention Pin: None, Bracket: 1 (Bracket)

Symbol: 11 (Body Ported), Voltage: 6 (12 VDC), Wetted Part Material: A (Plate: PEEK; Diaphragm: EPDM), Reverse Mounting Prevention Pin: None, Bracket: 1 (Bracket)

Symbol: 11 (Body Ported), Voltage: 6 (12 VDC), Wetted Part Material: B (Plate: PEEK; Diaphragm: FKM), Reverse Mounting Prevention Pin: None, Bracket: 1 (Bracket)

Symbol: 11 (Body Ported), Voltage: 6 (12 VDC), Wetted Part Material: C (Plate: PEEK; Diaphragm: Kalrez®)

Symbol: 11 (Body Ported), Voltage: 6 (12 VDC), Wetted Part Material: A (Plate: PEEK; Diaphragm: EPDM)

Symbol: 11 (Body Ported), Voltage: 5 (24 VDC), Wetted Part Material: B (Plate: PEEK; Diaphragm: FKM)