Rated Vacuum Range: -101 to 0 kPa, Output Specification: PNP Open Collector 1 Output, Unit Specification: w/Unit Selection Function, Initial Value psi, Piping Specification: ø4 One-touch Fitting, Straight Type, Option 1: -, Option 2: -, Option 3: -
Rated Vacuum Range: -101 to 0 kPa, Output Specification: PNP Open Collector 1 Output, Unit Specification: w/Unit Selection Function, Initial Value psi, Piping Specification: ø1/4" One-touch Fitting, Straight Type, Option 1: -, Option 2: -, Option 3: -
Rated Vacuum Range: -100 to 100 kPa, Output Specification: PNP Open Collector 1 Output, Unit Specification: w/Unit Selection Function, Initial Value psi, Piping Specification: ø4 One-touch Fitting, Straight Type, Option 1: -, Option 2: -, Option 3: -
Rated Vacuum Range: -101 to 0 kPa, Output Specification: PNP Open Collector 1 Output, Unit Specification: w/Unit Selection Function, Initial Value psi, Piping Specification: ø6 One-touch Fitting, Elbow Type, Option 1: -, Option 2: -, Option 3: -
Rated Vacuum Range: -101 to 0 kPa, Output Specification: PNP Open Collector 1 Output, Unit Specification: w/Unit Selection Function, Initial Value psi, Piping Specification: ø6 One-touch Fitting, Straight Type, Option 1: -, Option 2: -, Option 3: -
Rated Vacuum Range: -101 to 0 kPa, Output Specification: PNP Open Collector 1 Output, Unit Specification: w/Unit Selection Function, Initial Value psi, Piping Specification: R 1/8, Option 1: -, Option 2: -, Option 3: -
Rated Vacuum Range: -100 to 100 kPa, Output Specification: PNP Open Collector 1 Output, Unit Specification: w/Unit Selection Function, Initial Value psi, Piping Specification: ø1/4" One-touch Fitting, Straight Type, Option 1: -, Option 2: -, Option 3: -
Rated Vacuum Range: -100 to 100 kPa, Output Specification: PNP Open Collector 1 Output, Unit Specification: w/Unit Selection Function, Initial Value psi, Piping Specification: R 1/8, Option 1: -, Option 2: -, Option 3: -
PAB*-OMY0018 PRODUCT NAME Process Pump MODEL / Series / Product Number PA5010 Contents Safety Instructions -P.2 to 3 Names and functions of parts P.4 Precautions P.5 to 9 Applicable Fluids P.10 Specifications P.11 Performance Curve P.12 to 13 Working Principle P.14 Maintenance Parts P.14 Piping and Operation P.15 Dimensions P.16 1 Safety Instructions These safety instructions are intended
PAB*-OMY0027 PRODUCT NAME Process Pump MODEL / Series / Product Number PA5013 Contents Safety Instructions -P.2 to 3 Names and functions of parts P.4 Precautions -P.5 to 9 Applicable Fluids P.10 Specifications P.11 Performance Curve P.12 to 14 Working Principle P.15 Maintenance Parts P.15 Piping and Operation P.16 Dimensions P.17 1 Safety Instructions These safety instructions are intended
PAB-OM-E002-F PRODUCT NAME Process Pump MODEL / Series / Product Number PA(P)3313 Series Contents Safety Instructions -P.2 to 3 Names and functions of parts P.4 Precautions P.5 to 9 Applicable Fluids P.10 Specifications P.11 Performance Curve P.12 to 14 Working Principle P.15 Maintenance Parts P.15 Piping and Operation P.16 Dimensions P.17 1 Safety Instructions These safety instructions are
Refer to p.0-39 through 0-46 for Safety Instructions, actuator precautions and auto switch precautions. With Non-rotating Rod (Double Acting: Single Rod) Adjustment Warning Operating Precautions Caution q Do not open the cushion valve above the stopper.
Refer to "Flow Characteristics" (p.4.6-9) and figure of "Max. air flow" (p.4.6-8).
OUT1 OUT1 OUT2 OUT2 Refer to p.3.1-8 "Channel selection" for further information. ON YES PHysteresis mode OFF P-1 P-2 > = P Pressure/Vacuum Up H H H (fixed hysteresis) =2% F.S. ON PWindow comparator mode NO OFF P-1 P-2 Pressure/Vacuum Up OUT1 Output mode ON YES OUT2: Same as OUT1. PHysteresis mode OFF n-1 n-2 Pressure/Vacuum Up > = n H (fixed hysteresis) =2% F.S.
Transfer direction Transfer direction P R Applicable Auto Switches/Refer to pages 941 to 1067 for further information on auto switches.
resolution is 1048576 [Pulse/rev] P Travel amount per 1 command pulse [m] n1/n2 Pulley ratio *1 Ex.)
resolution is 1048576 [Pulse/rev] P Travel amount per 1 command pulse [m] n1/n2 Pulley ratio *1 Ex.)
Communication connectoe key P o w er su p p ly co n n ecto r key Bus adaptor 6 Sw i t ch set t i ng Saf et y I nst ruct i ons f or Set t i ng Turn of f t he pow er suppl y w hi l e set t i ng t he sw i t ch. I f t here i s f orei gn m at t er or w at er dropl et s around t he sw i t ch cover, cl ean i t of f bef ore openi ng t he cover.
Command pulse (maximum 225/kpps) P Class 3 ground Ground resistor 100 or less Incremental encoder P Deviation counter clear signal (active high) 2CN PG P Be sure to treat the shielding wire terminals. +12 to 24V Note) 4.7k 13 14 5mA Servo ON 1Ry 0V SV-ON 1Ry ON for servo ON 2Ry Proportional control (P actuation) Reverse drive suppression 15 P-CON 2Ry ON for proportional control N-LS 16 N-OT
Real-time switch output ( ) Unit switching Hysteresis mode Display Real-time flow rate l/min Accumulated flow l ON YES OFF P-1 P-2 GPM gal (US) Real-time flow rate GPM = gal (US)/min "P" Window comparator mode H : Hysteresis Note ) Fixed SI unit (l/min, l, m3 or m3x10) will be set for the type without the unit switching function.