VALVE DBL NON PLUGIN BASE MT, VALVE, VFR5000 SOL VALVE 4/5 PORT, RF, VFR5000 BASE MT 1/2, 3.32428 lb
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, VALVE, SOFT START 3/8, VALVE, AV SOFT START UP BODY PORT, GA, AV BODY PORT 3/8 NPT, 1.05821 lb
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, VALVE DBL SOLENOID BODY PT, VALVE, VFS2000 SOL VALVE 4/5 PORT, FF, VFS2000 BODY PT 1/4, 0.9862 lb
Series VFR consists of 5 port pilot solenoid valves with rubber seals and base mounted type manifolds, available in plug-in and non plug-in styles. Port sizes range from 1/8 to 1/2 with Rc(PT), NPTF and G(PF) thread types available. Various options also available. VFR3000, plug-in and non plug-in types, Maximum operating pressure: up to 0.9MPa, Ambient and fluid temperature: Max. 50C, Manual
Series VFS consists of 5 port pilot solenoid valves with metal seals and base mounted or body ported type manifolds. Base mounted manifolds are available in plug-in and non plug-in styles. Body ported manifolds are available with bar or separate type manifold bases. Port sizes range from 1/8 to 3/4 with Rc(PT), NPTF & G(PF) thread types available. Various options also available. VFS3000,
B)4/2 5/3 (A/B EA/EB) C[dm3/(s?
Series VFS consists of 5 port pilot solenoid valves with metal seals and base mounted or body ported type manifolds. Base mounted manifolds are available in plug-in and non plug-in styles. Body ported manifolds are available with bar or separate type manifold bases. Port sizes range from 1/8 to 3/4 with Rc(PT), NPTF and G(PF) thread types available. Various options also available. VFS2000
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, VALVE DBL NON PLUGIN BASE MT, VALVE, VFS5000 SOL VALVE 4/5 PORT, 2E, VFS5000, 3.7385 lb
Series AV is a soft start up valve for low-speed air supply to gradually raise initial pressure in an air system and for quick exhaust by cutting off air supply.
Series AV is a soft start up valve for low-speed air supply to gradually raise initial pressure in an air system and for quick exhaust by cutting off air supply.
Series AV is a soft start up valve for low-speed air supply to gradually raise initial pressure in an air system and for quick exhaust by cutting off air supply.
Series AV is a soft start up valve for low-speed air supply to gradually raise initial pressure in an air system and for quick exhaust by cutting off air supply.
Please contact us for the latest version.sales@ocaire.com, VALVE, SOFT START 3/4, VALVE, AV SOFT START UP BODY PORT, 1A, AV OTHER SIZE RATING, 3.86809 lb, ModelPort sizeProof pressureOperating pressure rangePressure gauge port sizeAmbient and fluid temperatureEffective area (mm2)Mass (kg)Electrical specificationsPilot valve manual override1(P) 2(A)2(A) 3(R)Rated coil voltageAllowable
Series AV is a soft start up valve for low-speed air supply to gradually raise initial pressure in an air system and for quick exhaust by cutting off air supply.
Series AV is a soft start up valve for low-speed air supply to gradually raise initial pressure in an air system and for quick exhaust by cutting off air supply.
In the event of setting, use a flat head screwdriver suited for the groove of a trimmer, and rotate it lightly with a finger tip. + 980 m/s2 X, Y, Z directions (3 times for each direction) Impact resistance High pressure High vacuum 5 g (Excluding lead wire) Weight 6 reducer Port size IP40 Enclosure Grommet oil-proof cabtire cord 2-wires 2.55, 0.18 mm2, 3 m Lead wire Pressure setting trimmer
Manifold Specifications Manifold Manifold type Number of valves Blanking plate (with gasket, screws) B Mount Common supply, Common exhaust, Individual out 2 to 10 stations VVX31 VX011-004 VX011-005 VVX32/33 JIS Symbol Port A Port A Port P Manifold Base and Applicable Solenoid Valve Part No. n: stations Port R Manifold base A port Applicable solenoid valve Base weight (g) VVX311-stations VVX312
Detaching To detach a socket from connector, pull out lead wire while pressing the socket's hook with a stick having a thin tip (about. 1 mm). If the socket will be used again, first spread the hook outward. Pressure exceeding 0.5 MPa is being applied. (The pressure over rated pressure is being applied in case of positive pressure.) Reset the supply pressure less than 0.5 MPa.
Fittings & Tubing Air Cylinders Rotary Actuators Relief port 2 x M5 x 0.8 2 x P through M5 x 0.8 R GC GB E GA MM D C J 2.8 2 x P through A 4 x T counterbore E 0.5 B H S Z (mm) 6 depth 4.8 5 S 10 15 20 25 30 5 Z 10 15 20 25 30 Bore size B C D E GA GB GC H J MM P R T A 13 22 3 23 16 15 13 10 3.2 7 M3 x 0.5 31 10 7 6 10 15 24 4 24 33.5 16 15.5 16 11 M4 x 0.7 3.2 9 6 depth 5 64 69 74 79 84 89
The difference between the part numbers with a “Z” and without a “Z” is that the “Z” is the symbol used to identify the new CM2 series cylinders. The old CM2 series was discontinued in September 2013, and it was replaced with the refreshed CM2-Z series.