SMC Corporation of America
Elite Part Number Search
Search Results "25A-MXQ6L-30C-M9N"

The new style MGP has a shorter guide rod and thinner plate resulting in a weight reduction of up to 17% over the original MGP.  The series is designed for high side load applications found in material handling, lifting and stopping. The cylinder utilizes an ultra-compact design by incorporating the cylinder body as part of the guide body. As the stroke length increases, so does the bearing

The new style MGP has a shorter guide rod and thinner plate resulting in a weight reduction of up to 17% over the original MGP.  The series is designed for high side load applications found in material handling, lifting and stopping. The cylinder utilizes an ultra-compact design by incorporating the cylinder body as part of the guide body. As the stroke length increases, so does the bearing

Series MHL air grippers are designed for applications that require a wide travel range of gripper fingers. The MHL is ideal for gripping many different sized parts. Finger motion is synchronized by a rack-and-pinion mechanism. The double piston construction creates a compact gripper with large holding force. Available in bore sizes 10, 16, 20, 25, 32 and 40. Axial mounting * or lateral mounting

Series MHL air grippers are designed for applications that require a wide travel range of gripper fingers. The MHL is ideal for gripping many different sized parts. Finger motion is synchronized by a rack-and-pinion mechanism. The double piston construction creates a compact gripper with large holding force. Available in bore sizes 10, 16, 20, 25, 32 and 40. Axial mounting * or lateral mounting

Auto switch Auto Switch Specifications D-M9N-5(With indicator light) Auto switch model D-M9N-5 Electrical entry direction In-line Wiring 3-wire Output NPN type Applicable load IC circuit,Relay,PLC Power supply voltage 5 , 12 , 24 VDC (4.5 to 28 V) Current consumption 10 mA or less Load voltage 28 VDC or less Load current 40 mA or less Internal voltage drop 0.8 V or less at 10 mA (2 V or less

D-M9N-5 ( ) D-M9N-5 3 NPN IC PLC DC51224V(4.528V) 10mA DC28V 40mA 10mA 0.8V (40mA 2V ) DC24V 100A ON CE RoHS D-M9N-5 M2.54L 15 - 5. 5-1. 1. () 2. 3. 4. 1. 5-2. 1. 2. 3. 4. Nm JMHZ2-16D M3x0.5 0.59 16 - M6x23 6.3Nm M4x10 1.0Nm 17 - P165-2. M3x7 0.59Nm 18 - (0.7mm) 19 - 5-3.

Auto switches of D-M9N, D-M9P, D-M9B, and D-M9A are used. Auto switches of D-M9NV, D-M9PV, D-M9BV, and D-M9AV are used. Max. Protrusion of Auto Switch from Edge of Body: L, H Max.

Nil (Example) M9N 3 m . L M9NL Refer to page 12-13-1 for further information on auto switches. Auto switches marked with a "" are made upon receipt of order.

M9N M9NV 3-wire (NPN) IC circuit 5 V, 12 V M9P M9PV 3-wire (PNP) M9B M9BV 2-wire 12 V 24 V Relay PLC Yes Grommet F9NW F9NWV 3-wire (NPN) 5 V, 12 V IC circuit Diagnostic indication (2-color indication) F9PW F9PWV 3-wire (PNP) F9BW F9BWV 2-wire Lead wire length symbols: 0.5 m Nil (Example) M9N 3 m L (Example) M9NL 5 m Z (Example) M9NZ 12 V Solid state switches marked are produced

Lead wire length symbols: 0.5 mNil (Example) M9N 3 m L (Example) M9NL 5 m Z (Example) M9NZ Refer to page 10-12-16 for details on other applicable auto switches than listed above.

Series MHZ2 112210, 16, 20, 25 Air Gripper How to Order 11 Vacuum suction type Clean series 11 MHZ2 16 D M9N 22 MHZ2 16 D M9N Copper, fluorine and silicone-free + Low particle generation Bore size 10 16 10 mm 16 mm 22 Vacuum suction type 20 mm 20 25 mm 25 Action Number of auto switches Double acting D Nil 2 pcs. S 1 pc.

Nil (Example) M9N 1 m . M (Example) M9NM 3 m . L (Example) M9NL 5 m . Z (Example) M9NZ Refer to page 889 for the applicable auto switch list. 799

Nil S Gripper Applicable Auto Switch Parallel type: 2 fingers Q Lead wire length (m) 0.5 (Nil) Indicator light Auto switch symbol Load voltage Wiring (output) Applicable load Auto switch model Type Electrical entry Electrical entry 5 (Z) 3 (L) DC Gripper bore In-line 10 16 20 25 10 mm 16 mm 20 mm 25 mm Solid state switches D-M9N-746 M9N M9P M9B 3-wire (NPN) 5V 12V IC circuit Relay PLC D-M9P

XMA XYA M9N 16 A A M9N 25 Angle type In-line type q w e r t y u w Flange type q Flange size XMA Type KF (NW) K (DN) CF Symbol Nil D C Applicable flange size 16, 25, 40, 50, 63, 80 63, 80 16 (034), 40 (070), 63 (114) XMA XYA Size 16 25 40 50 63 80 XYA Nil D K (DN) KF (NW) 25, 40, 50, 63, 80 63, 80 e Indicator/Pilot port direction XMA Rear flange surface XYA Symbol Rear flange surface Right

Load voltage Auto switch model Lead wire length [m] Pre-wired connector Applicable load DC AC Tie-rod mounting Band mounting 0.5 (Nil) 1 (M) 3 (L) 5 (Z) Indicator light Type Special function Electrical entry Wiring (Output) M9N V V V v v IC circuit 3-wire (NPN) 5 V, 12 V 3-wire (PNP) M9P V V V v v 2-wire 12 V M9B V V V v v Terminal conduit 3-wire (NPN) 5 V, 12 V G39 IC circuit 2-wire

Load voltage Auto switch model Lead wire length [m] Pre-wired connector Applicable load DC AC Perpendicular In-line 0.5 (Nil) 1 (M) 3 (L) 5 (Z) Indicator light Type Special function Electrical entry Wiring (Output) M9NV M9N IC circuit 3-wire (NPN) 5 V, 12 V 3-wire (PNP) M9PV M9P 2-wire 12 V M9BV M9B Solid state auto switch 3-wire (NPN) 5 V, 12 V M9NWV M9NW IC circuit 3-wire (PNP) M9PWV M9PW

Load voltage Auto switch model Perpendicular Lead wire length (m) Yes No Yes No Yes Yes Indicator light Pre-wired connector Wiring (Output) Applicable load Type Special function Electrical entry In-line 0.5 (Nil) 1 (M) 3 (L) 5 (Z) None (N) DC AC 16, 20, 32 to 50 12 16, 20, 32 to 50 12 M9N M9P M9B M9NW M9PW M9BW M9NA M9PA M9BA M9NV M9PV M9BV 5 V, 12 V 3-wire (NPN) 3-wire (PNP) Grommet IC

(D-M9 only) Recommended Tool Description Wire stripper Model D-M9N-SWY Stripper for a round cable (2.0) can be used for a 2-wire type cable. 12 Auto Switches Precautions 4 Be sure to read this before handling. Operating Environment Warning Caution 1. Never use in an atmosphere of explosive gases. The structure of auto switches is not intended to prevent explosion.

Weight (g) LEC S LEC SS-T D-M9P(V) D-M9B(V) D-M9N(V) Auto switch model 0.5 m (Nil) 8 7 LEC Y 1 m (M) 14 13 Lead wire length 3 m (L) 41 38 Motorless 5 m (Z) 68 63 LAT Dimensions LZ (mm) D-M9 D-M9V LC3F2 M2.5 x 4 L M2.5 x 4 L Indicator light Slotted set screw Slotted set screw 8 Indicator light 2 3.2 4.6 2.6 4 2.8 2.7 2.7 20 2.8 4 22 3.2 2.6 9.5 Most sensitive position 6 4 6 Most sensitive

Lead wire length symbols: 0.5 mNil (Example) M9N 3 m L (Example) M9NL 5 m Z (Example) M9NZ Refer to page 10-12-16 for details on other applicable auto switches than listed above.