Main Body Peripheral Component: Main Body, Type: Sliders, Stroke(mm): 700, Max. Transportable Mass Range (Horizontal)(kg): 10.1 to 20.0, Max. Transportable Mass (Horizontal)(kg): 19, Drive Method: Belts, Guide: Included, Lead(mm): 48, Input Power Supply: DC 24V, Position Detection: Incremental, I/O Module: Not Provided, Table Width W1(mm): 60, Brake: Not Provided, Noise Filters: Not Provided
Main Body Peripheral Component: Main Body, Type: Sliders, Stroke(mm): 800, Max. Transportable Mass Range (Horizontal)(kg): 10.1 to 20.0, Max. Transportable Mass (Horizontal)(kg): 19, Drive Method: Belts, Guide: Included, Lead(mm): 48, Input Power Supply: DC 24V, Position Detection: Incremental, I/O Module: Not Provided, Table Width W1(mm): 60, Brake: Not Provided, Noise Filters: Not Provided
Main Body Peripheral Component: Main Body, Type: Sliders, Stroke(mm): 900, Max. Transportable Mass Range (Horizontal)(kg): 10.1 to 20.0, Max. Transportable Mass (Horizontal)(kg): 19, Drive Method: Belts, Guide: Included, Lead(mm): 48, Input Power Supply: DC 24V, Position Detection: Incremental, I/O Module: Not Provided, Table Width W1(mm): 60, Brake: Not Provided, Noise Filters: Not Provided
Main Body Peripheral Component: Main Body, Type: Sliders, Stroke(mm): 900, Max. Transportable Mass Range (Horizontal)(kg): 10.1 to 20.0, Max. Transportable Mass (Horizontal)(kg): 19, Drive Method: Belts, Guide: Included, Lead(mm): 48, Input Power Supply: DC 24V, Position Detection: Incremental, I/O Module: Not Provided, Table Width W1(mm): 60, Brake: Not Provided, Noise Filters: Not Provided
Series LECP6 controller has two available modes for the setting software and teaching box. In the easy mode, the operation can be started by only setting the speed, position, etc. Using the normal mode allows a further detailed setup. A few of the main functions of the LECP6 controller are actuator control, specified force operation, separated power supply, and returning the actuator
LE ACTUATOR, NO SIZE RATING, ACTUATOR, ELECTRIC ACTUATOR, 2C, LE ACTUATOR, NO SIZE RATING, 0.66138 lb
IO-LINK DC CONTROLLER, ELECTRIC ACTUATOR CONTROLLER, N31, 0.19 lb
CC-LINK DC CONTROLLER, ELECTRIC ACTUATOR CONTROLLER, N31, 0.24 lb
Series LECPA pulse input driver, combined with a 24 volt step motor, permits control of position, speed, acceleration and deceleration using pulse signals. The LECPA is a step motor driver compatible with a variety of SMC's electric actuators including the LEY, LEF, LES, LER and LEP series.Step motor driver , Pulse input type , For step motor, PNP DC Pulse Step Controller, ELECTRIC ACTUATOR
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CONTROLLER STEP PNP, ACTUATOR, ELECTRIC ACTUATOR, IC, 25MM LE ELECTRIC ACTUATOR, 2.13113 lb
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CONTROLLER, STEP PNP, ACTUATOR, ELECTRIC ACTUATOR, LC, 32MM LE ELECTRIC ACTUATOR, 1.98416 lb
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CONTROLLER, STEP PNP, ACTUATOR, ELECTRIC ACTUATOR, IC, 25MM LE ELECTRIC ACTUATOR, 1.98416 lb
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CONTROLLER STEP PNP, ACTUATOR, ELECTRIC ACTUATOR, IC, 25MM LE ELECTRIC ACTUATOR, 2.13113 lb, ModelBoltMax. tightening torque (N m)L (mm)LESH25R/LM6 x 15.250.5
Series LECP6 controller has two available modes for the setting software and teaching box. In the easy mode, the operation can be started by only setting the speed, position, etc. Using the normal mode allows a further detailed setup. A few of the main functions of the LECP6 controller are actuator control, specified force operation, separated power supply, and returning the actuator
LECP1 series is a programless controller capable of setting up an electric actuator operation without using a PC or teaching box. Through the combination of parallel I/O inputs, 14 points of positioning are available. The speed and acceleration of the positioning can be set by the switch for each operating direction. A single signal sent to a dedicated terminal returns an actuator to
Series LECPA pulse input driver, combined with a 24 volt step motor, permits control of position, speed, acceleration and deceleration using pulse signals. The LECPA is a step motor driver compatible with a variety of SMC's electric actuators including the LEY, LEF, LES, LER and LEP series.Step motor driver , Pulse input type , For step motor, NPN PULSE I/O DC CONTROLLER, ELECTRIC ACTUATOR
Protocol: L (IO-Link), Number of Axes, Special Specifications: F (1 Axis, w/STO Sub-function), Mounting: 7 (Screw Mounting), Actuator: LEFB (Belt Drive), Type: Basic Type, Body Size: 32, Motor Mounting: In-line, Lead: T (48mm), Stroke: 500mm
LECP1 series is a programless controller capable of setting up an electric actuator operation without using a PC or teaching box. Through the combination of parallel I/O inputs, 14 points of positioning are available. The speed and acceleration of the positioning can be set by the switch for each operating direction. A single signal sent to a dedicated terminal returns an actuator to
Series LECP6 controller has two available modes for the setting software and teaching box. In the easy mode, the operation can be started by only setting the speed, position, etc. Using the normal mode allows a further detailed setup. A few of the main functions of the LECP6 controller are actuator control, specified force operation, separated power supply, and returning the actuator
EtherNet/IP Direct Connect, JXC, ELECTRIC ACTUATOR CONTROLLER, 0.13000 lb