Integrated Type/For Output Series EX140 SZ3000 SQ1000/2000 How to Order SI Unit DN1 EX140 S Communication protocol DN1 MJ1 CS1 CS2 SL1 SL2 UW1 UH1 DeviceNet CC-Link OMRON Corp.: CompoBus/S (16 outputs) OMRON Corp.: CompoBus/S (8 outputs) SUNX Corp.: S-LINK (16 outputs) SUNX Corp.: S-LINK (8 outputs) NKE Corp.: Uni-wire System NKE Corp.: Uni-wire H System Note) Please consult SMC for networks
Nil S n Auto switch Thread type Nil Without auto switch (Built-in magnet) Refer to the table below for the applicable auto switch model. Type Bore size 16 Symbol M thread Rc NPT G Nil TN TF 25, 40 Stroke adjusting unit position Nil S Both ends One end Piping S is applicable for stroke adjusting units L and H.
Piston Speed Standard Stroke Bore size (mm) 16 25 40 63 20 32 50 Bore size (mm) Max. manufacturable stroke (mm) Standard stroke (mm) 80 to 500 mm/s Without stroke adjustment unit (MY3A) 80 to 1000 mm/s Without stroke adjustment unit (MY3B) 16, 20, 25 32, 40, 50 63 100, 200, 300, 400, 500, 600 700, 800, 900, 1000, 1200 1400, 1600, 1800, 2000 3000 80 to 1000 mm/s (16, 20 L unit: 80 to 800 mm
Stainless Steel Cylinder Se ries CG5-S 20, 25, 32, 40, 50, 63, 80, 100 How to Order X165US TN CG5 L N 25 S R 100 Without Auto Switch X165US TN CDG5 L N 25 S 100 G5BAL R With Auto Switch Inch rod thread (Only available with "TN" port option. Currently only available on the 20 to 63mm bore sizes.)
L 16 60 S 5 L CVJ3 Without auto switch L S 5 L J79W 16 60 CDVJ3 With auto switch Number of auto switches Action S T Single acting, Spring return Single acting, Spring extend Built-in magnet 2 pcs. 1 pc. n pcs.
Piston Speed -X168 Helical insert thread Symbol Specifications Without stroke adjustment unit 25 to 40 Bore size (mm) 100 to 1000 mm/s MY1B Made to Order Click here for details Note 1) 100 to 1000 mm/s A unit L unit and H unit Stroke adjustment unit Note 2) 100 to 1500 mm/s MY1H MY1H Symbol Specifications Note 1) Be aware that when the stroke adjustment range is increased with the adjustment
R and S (Because S function is also included in R.) S and T (Because S function is also included in T.) The combination of K, L and M is not possible because an auto drain can only be attached to a single option. 2 The maximum operating pressure is 1.6 MPa. 3 Voltage symbol 20 (200 VAC) is the terminal block connection as standard. The Option S cannot be chosen.
Also, when exceeding the air cushion stroke ranges on page 1191, the piston speed should be 100 to 200 mm/s. Note 2) The piston speed is 100 to 1000 mm/s for centralized piping. Note 3) Use at a speed within the absorption capacity range. Refer to page 1191.
Metal bowl PPA Applicable model Metal bowl with level gauge Metal bowl AL Optional specifications B B B B B N.O.: Black N.C.: Gray M5 x 0.8 Barb fitting Applicable tubing: T0604 B B O S 1/4 10 One-touch fitting Width across flats 17 O S (mm) With bracket Accessory specifications With auto-drain Port size Standard specifications Model M 2.3 2.3 2.3 2.3 B 115 170 204 208 L 40 53 70 70 H 22
Applicable model Metal bowl with level gauge Metal bowl Metal bowl Optional specifications B B B B B N.O.: Black N.C.: Gray M5 x 0.8 Barb fitting Applicable tubing: T0604 B B O S 10 One-touch fitting O S 1/4 Width across flats 17 (mm) With bracket Accessory specifications Port size Standard specifications With auto-drain Model L 40 53 70 70 M 2.3 2.3 2.3 2.3 B 115 170 204 208 K 8.4 8 10.5
Piston speed 20 to 63 50 to 300 mm/s 80, 100 Note) Stroke length tolerance dose not include the amount of bumper change.
Speed : The moving speed for jog transfer and pitch transfer is specified. -23JXC-OMU0010-A 5.3.3 Alarm window The currently occurring alarm and the past alarm(s) (up to 16 past alarms) can be seen. The current and past is switched by selecting the tab. Currently occurring alarm Past alarm(s) Reset : The alarm(s) can be deleted *Some alarms cannot be deleted by this button.
S 13 13.1 13.2 IDF15E1-20 L N PE M3 6.5mm 1.25mm 2 13 1 13.S 13.3 IDF15E-10-S PE N L TB CM ILS FM PTC OLR OLR ILS PTC PTC CM PRS C01 C02 TB C01 C02 C11 FM C11 PRS P 13 2 14.T T 14 14.1 IEC 14.2 AC200V, 1A (AC10mA, DC30mA) 14.3 ON 3 () 5 /1 () 14 1 14.T 14.4 PE 1 2 3 PE: LN: LN PE M3 6.5mm 1.25mm 2 () () 14 2 14.T 14.5 IDF15E1-10-T IDF15E1-20-T 2 1 L N TB PE
IDX-OM-W014-C / Series IDU3E-10(-C,K,L,M,R,S,T) IDU3E-20(-C,K,L,M,R,T) IDU4E-10(-C,K,L,M,R,S,T) IDU4E-20(-C,K,L,M,R,T) IDU6E-10(-C,K,L,M,R,S,T) IDU6E-20(-C,K,L,M,R,T) IDU3E-23(-C,K,L,R,T,V) IDU4E-23(-C,K,L,R,T,V) IDU6E-23(-C,K,L,R,T,V) URLhttps://www.smcworld.com/ English instruction manual can be downloaded from our URLhttps://www.smcworld.com/ SMC ISO4414 * 1) JIS B8370 *2 ) *1) ISO 4414
IDX-OM-W023-B / Series IDU8E-10(-C,K,L,M,R,S,T) IDU8E-20(-C,K,L,M,R,T) IDU11E-10(-C,K,L,M,R,S,T) IDU11E-20(-C,K,L,M,R,T) IDU15E1-10(-C,K,L,M,R,S,T) IDU15E1-20(-C,K,L,M,R,T) IDU8E-23(-C,K,L,R,T,V) IDU11E-23(-C,K,L,R,T,V) IDU15E1-23(-C,K,L,R,T,V) URLhttps://www.smcworld.com/ English instruction manual can be downloaded from our URLhttps://www.smcworld.com/ SMC ISO4414 * 1) JIS B8370 *2 )
Membrane module kit and Dew point indicator kit Name Membrane module kit Dew point indicator kit Model IDG3 (Option : S) IDG-EL3 IDG3H (Option : S) IDG-EL3H IDG5 (Option : S) IDG-EL5 IDG5H (Option : S) IDG-EL5H IDG10 IDG-EL10 IDG-DP01 IDG10H IDG-EL10H IDG20 IDG-EL20 IDG20H IDG-EL20H IDG30A IDG-EL30A IDG50A IDG-EL50A IDG60LA, 60SA IDG-EL60LA IDG75LA, 75SA IDG-EL75LA IDG100LA, 100SA IDG-EL100LA
Membrane module kit (Element) and Dew point indicator KIt Name Membrane module set Dew point Checker set Model IDG3 (Option : S) IDG-EL3 IDG3H (Option : S) IDG-EL3H IDG5 (Option : S) IDG-EL5 IDG5H (Option : S) IDG-EL5H IDG10 IDG-EL10 IDG-DP01 IDG10H IDG-EL10H IDG20 IDG-EL20 IDG20H IDG-EL20H IDG30A IDG-EL30A IDG50A IDG-EL50A IDG60LA, 60SA IDG-EL60LA IDG75LA, 75SA IDG-EL75LA IDG100LA, 100SA
Before machinery/equipment i s restarted, take measures to prevent unexpected operation and malfunction. s restarted, take measures to prevent unexpected operation and malfunction. s restarted, take measures to prevent unexpected operation and malfunction. s restarted, take measures to prevent unexpected operation and malfunction. s restarted, take measures to prevent unexpected operation
Display to show the standard product Names of individual parts 1 s Output (OUT1) display (Green) Output (OUT2) display (Red) Display to show the unit specification button (SET) 1 s Connector LED display ZSE10(F)/ISE10 Display to show the product Pin No. of the Connector button (UP) Socket Housing DC(+) Brown 5 Pin No. 1 s button (DOWN) Display to show the pressure range OUT1 Black 4 OUT2
110 -10 Pam 3/s A B C 0.0-101.0kPa 0 -101.0 kPa -100.0100.0kPa -100 kPa 100 kPa -0.1001.000MPa -0.1 MPa 0 1.