Skip valve function Combination of 2 or more valves of VNA series provides a skip valve function. Connect the skip valve to the A port side of a stop valve.

Caution indicates a hazard with a low level of risk which, if not avoided, could result in minor or moderate injury. Caution: Warning indicates a hazard with a medium level of risk which, if not avoided, could result in death or serious injury. Warning: Danger : Danger indicates a hazard with a high level of risk which, if not avoided, will result in death or serious injury.

In actual application, only one color is displayed at a time. Abnormal conditions can be detected at a glance!

HS Auto switch 36 12 24.5 SMC SMC A 33 B Auto switch 49.5 A B G 1/2 (applicable cable O.D. 6.8 to 11.5) Proper auto switch mounting positions (mm) D-H7 D-H7C D-H7W D-H7BAL D-C7 D-C8 D-C73C D-C80C D-G39 D-K39 D-A33, D-A34 D-A44 D-B5 D-B6 D-G5NTL D-H7F D-B59W Bore size (mm) A A B A A A A B A B B B B B 20 14 10 8.5 12 10.5 14 9 15 13 12 6.5 8.5 12 7 25 14.5 12.5 9.5 9 11 14.5 9.5 12.5 15.5 11.5

Options Element sealing method Flat gasket (D.O.E) 1 N/A Bracket Quick plug Nil B P Housing material A square plug set is normally used for the drain unit.

First, tighten the threaded portion by hand, then use a proper wrench, which could be suitable for the width across flats of the hexagon body, to tighten it further at a wrench tightening angle shown in the table below. For a tightening torque guide, refer to the table below. For R, NPT Thread (With sealant) Tightening method 1.

LN: Without lead wire LO: Without connector MO: Without connector R: External pilot type + -+ E: Push-turn locking lever type SYJ32R is only for manifold use. LN, MN type: with 2 sockets. For connector cable of M8 connector, refer to page 4-4-60. Note) When placing an order for body ported solenoid valve as a single unit, mounting bolt for manifold and gasket are not attached.

If a directional switching valve (solenoid valve, mechanical valve, etc.) is mounted on the supply side of the regulator and repeatedly switched ON and OFF, wear of the nozzle/flapper section will be accelerated and a discrepancy in the setting value may occur. Therefore, avoid using a directional switching valve on the supply side.

Standard Specifications AC20-A AC25-A AC30-A AC40-A AC40-06-A Model AF40-06-A AR40-06-A AL40-06-A AF40-A AR40-A AL40-A AF30-A AR30-A AL30-A AF30-A AR25-A AL30-A AF20-A AR20-A AL20-A Air filter Regulator Lubricator Component Port size Pressure gauge port size Fluid 3/4 1/8, 1/4 1/4, 3/8 1/8 1/4, 3/8 1/4, 3/8, 1/2 Air 5 to 60C (with no freezing) 1.5 MPa 1.0 MPa 0.05 to 0.7 MPa 5 m Class 1

Refer to page 7-2-5. 2-M3 x 0.5 (Port size) M3 x 0.5 (Relief port: 10See above) (Vacuum port: 11See above) 3.5 20Data C + Stroke 3 B + Stroke A + Stroke Without auto switch With auto switch A B C A B C Bore size (mm) 24 18 29 23 11.5 16.5 6, 8, 10 7-2-7 7 Series CUJ Construction Double acting !3 w e q !1 r y o e t !

Product with Nuts How to order a flow sensor, PF2D5S series, etc. nut type fittings without a nut (including insert bushings) in one place.

single knuckle joint, which may be used as a guide.

In such a case, adjust the open angle of its bleed valve to lower the pressure a bit inside the bowl, so that drainage will run through easily. Selection Caution 1. The maximum dischargeable drainage rate is 400 cc/min. If the product is operated in excess of this value, there is a risk of causing the drainage to flow over to the outlet side. Piping Caution 1.

) (Back side 2(B)) Main port T C Port size: refer to table below A B VNH VND VND Main port 1(A), 2(B) A B C D E F G M N P Q R S T U Model VCC VND20D-10A VND20D-15A VND30D-20A VND40D-25A 3 8 1 2 3 4 1 63 42 28 14 73.5 81.5 4 52 26 4.5 24.3 2.3 25 34 56 TQ 80 90 50 60 35 44 17.5 22 85 101 93 109 5 6 62 72 31 36 5.5 6.5 28.3 33.3 2.3 2.3 30 35 43 49 61.5 74 637 A VND Series Port size: 32A, 40A

A N01 NPT1/8 (M5) W1 Rc1/8 B B WF1 G1/81 D D M5 M5X0.8 () E C4 4 C6 6 F + 1IS0228-1 P10/1 X NPN2() Y PNP2() 1 R NPN2 +/ T PNP2 +/ M SI2 P (psi)1 S NPN2 +/ 1 2kPaMPa V PNP2 +/ -9No.PS-OMM0006CN-E /1 1 01 N01 W1 WF1 M5 C4 C6 A A ZS-24-A X X X B B ZS-24-B X X X X X D D ZS-24-D X X X ZS-35-C X X X X X E ZS-35-D X X ZS-35-F X X X X X + F ZS-35-G X X 1/ 1 ZS-24-A A M35 L,M45

Note 5) For command pulse input with a differential line driver method.

/LITHUANIA SMC Pneumatik A/S SMC Pneumatiques (Canada) Ltd.

A part B part Procedure Calculation Calculation example 1. Check the operating conditions, dimensions of attachment, etc. Operating model: MHY2-16D Opening time: 0.15 s a = 40 (mm) b = 7 (mm) c = 8 (mm) d = 5 (mm) e = 10 (mm) f = 12 (mm) A part a b c B part e f d 2.