[F90] [ ALL] Setting of all functions [ oFF] OFF 4 C/Q Black Communication data (IO-Link)/Switch output 1 (SIO) [F98] [ tESt] OUT1 output test mode [ n] Normal output : When using the lead wire with M8 connector included with the PF3W7 series.
Symbol: Body Ported, 2 Port, N.C., M5 Thread, Function: Standard, Voltage: 24 VDC, Wetted Part Material: Plate: PEEK; Diaphragm: Kalrez®, Sub-plate Material, Port Size: w/o Sub-plate, Option: Bracket + Manual Override, Lead Wire Length: -
Symbol: Body Ported, 2 Port, N.C., M5 Thread, Function: Standard, Voltage: 12 VDC, Wetted Part Material: Plate: PEEK; Diaphragm: FKM, Sub-plate Material, Port Size: w/o Sub-plate, Option: Bracket + Manual Override, Lead Wire Length: -
Symbol: Body Ported, 2 Port, N.C., M5 Thread, Function: Standard, Voltage: 12 VDC, Wetted Part Material: Plate: PEEK; Diaphragm: EPDM, Sub-plate Material, Port Size: w/o Sub-plate, Option: Manual Override, Lead Wire Length: -
Symbol: Body Ported, 2 Port, N.C., M5 Thread, Function: Standard, Voltage: 12 VDC, Wetted Part Material: Plate: PEEK; Diaphragm: EPDM, Sub-plate Material, Port Size: w/o Sub-plate, Option: Bracket + Manual Override, Lead Wire Length: -
Symbol: Body Ported, 2 Port, N.C., M5 Thread, Function: Standard, Voltage: 24 VDC, Wetted Part Material: Plate: PEEK; Diaphragm: EPDM, Sub-plate Material, Port Size: w/o Sub-plate, Option: Bracket + Manual Override, Lead Wire Length: -
Symbol: Body Ported, 2 Port, N.C., M5 Thread, Function: Standard, Voltage: 24 VDC, Wetted Part Material: Plate: PEEK; Diaphragm: FKM, Sub-plate Material, Port Size: w/o Sub-plate, Option: Bracket + Manual Override, Lead Wire Length: -
: Electromagnetic Type, Switching Type: Normally Closed, Body Material: Resin, Connection Type: M, Plumbing Thread Nominal: M5, Tube Diameter: -, Operating Temperature Range(°C): 0~50, Driving Type: Linear Motion Type, Orifice Diameter(Ø): 1.5, Insulation Class: B, Pipe opening type (details): Body Ported Type, Voltage: 24 V DC, Option: None, Power Consumption(W): Inrush: 2.5 / Holding: 1,
Symbol: 11 (Body Ported), Voltage: 5 (24 VDC), Wetted Part Material: B (Plate: PEEK; Diaphragm: FKM), Reverse Mounting Prevention Pin: None, Bracket: None, Lead Wire Length: 10 (Grommet, 1000mm; Light/Surge: No)
Symbol: 11 (Body Ported), Voltage: 5 (24 VDC), Wetted Part Material: C (Plate: PEEK; Diaphragm: Kalrez®), Reverse Mounting Prevention Pin: None, Bracket: None, Lead Wire Length: 10 (Grommet, 1000mm; Light/Surge: No)
Symbol: 11 (Body Ported), Voltage: 5 (24 VDC), Wetted Part Material: A (Plate: PEEK; Diaphragm: EPDM), Reverse Mounting Prevention Pin: None, Bracket: None, Lead Wire Length: 10 (Grommet, 1000mm; Light/Surge: No)
This is a legacy product. Please contact us for the latest version.sales@ocaire.com
Symbol: Body Ported, Voltage: 24 VDC, Wetted Part Material: Plate: PEEK; Diaphragm: FKM, Reverse Mounting Prevention Pin: None, Bracket: None, Lead Wire Length: Grommet, 1000mm; Light/Surge: No, CE Compliant: -
Symbol: Body Ported, Voltage: 24 VDC, Wetted Part Material: Plate: PEEK; Diaphragm: EPDM, Reverse Mounting Prevention Pin: None, Bracket: None, Lead Wire Length: Grommet, 1000mm; Light/Surge: No, CE Compliant: -
8 NPT 1/8 None With seal Lead wire length 3 m Regulating pressure range 0.1 to 0.6 MPa Nil S X202 Lead wire length 3 m Regulating pressure range 0.1 to 0.6 MPa X215 16-9-1 2 Series IS1000 Construction 5 500 50 20 t u 0.1 0.2 y 0.3 0.4 i 58.5 MPa q Component Parts !
Pressure Setting 1. Internal circuit and example of wiring Caution Caution Circuit Vcc D1 1. Pressure setting While pressing q SET, turn pressure-setting slotted screw e P.SET (counterclockwise to decrease) and watch the LCD. When the LCD shows the correct figure, stop turning P.SET and release the SET button. Set pressure is displayed on the pressure display panel r LCD.
Bracket (Option) AV R 1/8, 1/4 Dedicated mounting screw AU 22 14 (Hex. width across flats) (M4 x 0.7) M5 x 0.8 38 AF 2 26 2-4.5 600 8 AR Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com (Lead wire length) 19 3 25 IR 5 9 8 5 VEX 36 1 3 22 22 AMR 3.2 ITV IC M5 type
How to Order 100 IP200 Applicable stroke 25 to 300 mm * Manufacture of strokes in 1 mm increments is possible. Specifications (No load) Note 1) Replacement Parts Supply pressure 0.3 to 0.7 MPa Input pressure 0.02 to 0.1 MPa Part no.
Service life (based on SMC test conditions) is 10 million cycles or more.Orifice diameter of LVM11: 1.5mm, Orifice diameter of LVM10: 1.4mm , Available with power-saving circuit , 2 port N.C. or N.O. types; 3 port Universal type , Diaphragm choice of EPDM, FKM or Kalrez« , Wetted part material: PEEK or PFA (body/plate), CHEMICAL VALVE, CHEMICAL VALVE, 2 PORT, B07, 0.034 lb
Service life (based on SMC test conditions) is 10 million cycles or more.Orifice diameter of LVM11: 1.5mm, Orifice diameter of LVM10: 1.4mm , Available with power-saving circuit , 2 port N.C. or N.O. types; 3 port Universal type , Diaphragm choice of EPDM, FKM or Kalrez« , Wetted part material: PEEK or PFA (body/plate), CHEMICAL VALVE, CHEMICAL VALVE, 2 PORT, B07, 0.034 lb