SMC Corporation of America
Elite Part Number Search
Search Results "VH600-10-R"

Fluid: air, inert gas , Operating pressure range: 0.1 - 0.7MPa (high pressure style: 1.0MPa) , Cv factor: 1 2 (P A) 0.23; 2 3 (A R) 0.25 , Coil rated voltage: 12, 24VDC; 100, 110, 200, 220VAC , Response time: metal seal 14ms or less; rubber seal 15ms or less , Ambient and fluid temperature: -10 to 50C, VALVE, BODY PORTED (DC), VALVE, VQZ100 VALVE, SOL 3-PORT, UA, VQZ100 BUILT IN FITTING

Fluid: air, inert gas , Operating pressure range: 0.1 - 0.7MPa (high pressure style: 1.0MPa) , Cv factor: 1 2 (P A) 0.23; 2 3 (A R) 0.25 , Coil rated voltage: 12, 24VDC; 100, 110, 200, 220VAC , Response time: metal seal 14ms or less; rubber seal 15ms or less , Ambient and fluid temperature: -10 to 50C, VALVE, BODY PORTED (DC), VALVE, VQZ100 VALVE, SOL 3-PORT, BA, VQZ100 BODY

KQ fittings are available to order in multiples of 10.The current KQ series fitting has been discontinued. SMC has introduced an improved version of KQ2 series, and recommends that you utilize the new series for your product designs.

Fluid: air, inert gas , Operating pressure range: 0.1 - 0.7MPa (high pressure style: 1.0MPa) , Cv factor: 1 2 (P A) 0.23; 2 3 (A R) 0.25 , Coil rated voltage: 12, 24VDC; 100, 110, 200, 220VAC , Response time: metal seal 14ms or less; rubber seal 15ms or less , Ambient and fluid temperature: -10 to 50C, VALVE, BASE MOUNTED (DC), VALVE, VQZ100 VALVE, SOL 3-PORT, 2A, VQZ100 NO

Fluid: Air, Operating pressure range: up to 0.7Mpa, Valve effective area mm² (Cv factor): P to A/B 3.0 to 3.7 (0.17 to 0.21) A/B to R 3.2 to 3.9 (0.18 to 0.22), Coil rated voltage: 24, 12, 6, 5, 3DC, Response time: minimum 10 or less

Series AN is available with M, R or NPT threads. Fluid: compressed air, Noise reduction: 25-35 dB(A) or more, Maximum operating pressure: 1.0MPa, Effective area mm 2 (Cv): AN*00 35-960 (1.9-53); AN*02 35-90 (1.9-5.0); AN*03 10-60 (0.6-3.3), Ambient and fluid temperature: 5 - 60 C, SILENCER, AIRLINE EQUIPMENT, AN SILENCER, DB, AN 1/4INCH STANDARD (PT), .01556 lb

Fluid: air, inert gas , Operating pressure range: 0.1 - 0.7MPa (high pressure style: 1.0MPa) , Cv factor: 1 2 (P A) 0.23; 2 3 (A R) 0.25 , Coil rated voltage: 12, 24VDC; 100, 110, 200, 220VAC , Response time: metal seal 14ms or less; rubber seal 15ms or less , Ambient and fluid temperature: -10 to 50C, VALVE, BODY PORTED (DC), VALVE, VQZ100 VALVE, SOL 3-PORT, UA, VQZ100 BUILT

Fluid: air, inert gas , Operating pressure range: 0.1 - 0.7MPa (high pressure style: 1.0MPa) , Cv factor: 1 2 (P A) 0.23; 2 3 (A R) 0.25 , Coil rated voltage: 12, 24VDC; 100, 110, 200, 220VAC , Response time: metal seal 14ms or less; rubber seal 15ms or less , Ambient and fluid temperature: -10 to 50C, VALVE, BODY PORTED (DC), VALVE, VQZ100 VALVE, SOL 3-PORT, UA, VQZ100 BUILT

Speed controller with one-touch fittings, Body sizes: M5, 01, 02, 03, 05, Metal body elbow style, Meter-in or meter-out control, Port sizes: M5, 01, 02, 03, 04, Tube O.D.: 04, 06, 08, 10, 12, SPEED CONTROL W/FITTING, AIRLINE EQUIPMENT, AS FLOW CONTROL, 1B, AS OTHER SIZE STANDARD (PT), .03800 lb

(Cv factor): P to A/B 3.0 to 3.7 (0.17 to 0.21) A/B to R 3.2 to 3.9 (0.18 to 0.22), Coil rated voltage: 24, 12, 6, 5, 3DC, Response time: minimum 10 or less, FITTING LONG ELBOW, VALVE, SV2000 SOLENOID VALVE, 5-PORT, 21, SV2000 NO SIZE RATING, .02204 lb

Fluid: Air, Operating pressure range: up to 0.7Mpa, Valve effective area mm² (Cv factor): P to A/B 3.0 to 3.7 (0.17 to 0.21) A/B to R 3.2 to 3.9 (0.18 to 0.22), Coil rated voltage: 24, 12, 6, 5, 3DC, Response time: minimum 10 or less, FITTING, ELBOW, 4/5 PORT SOLENOID VALVE

Speed controller with one-touch fittings, Body sizes: M5, 01, 02, 03, 05, Metal body elbow style, Meter-in or meter-out control, Port sizes: M5, 01, 02, 03, 04, Tube O.D.: 04, 06, 08, 10, 12, "SPEED CONTROLLER, FLOW CONTROL

Speed controller with one-touch fittings, Body sizes: M5, 01, 02, 03, 05, Metal body elbow style, Meter-in or meter-out control, Port sizes: M5, 01, 02, 03, 04, Tube O.D.: 04, 06, 08, 10, 12, "SPEED CONTROLLER, FLOW CONTROL

Speed controller with one-touch fittings, Body sizes: M5, 01, 02, 03, 05, Metal body elbow style, Meter-in or meter-out control, Port sizes: M5, 01, 02, 03, 04, Tube O.D.: 04, 06, 08, 10, 12, "SPEED CONTROLLER, FLOW CONTROL

(Cv factor): P to A/B 3.0 to 3.7 (0.17 to 0.21) A/B to R 3.2 to 3.9 (0.18 to 0.22), Coil rated voltage: 24, 12, 6, 5, 3DC, Response time: minimum 10 or less, VALVE, PLUG IN, VALVE, SJ2000/SJ3000/SZ3000, UD, SZ BUILT IN FITTING 1/4), .15432 lb

Fluid: air, inert gas , Operating pressure range: 0.1 - 0.7MPa (high pressure style: 1.0MPa) , Cv factor: 1 2 (P A) 0.23; 2 3 (A R) 0.25 , Coil rated voltage: 12, 24VDC; 100, 110, 200, 220VAC , Response time: metal seal 14ms or less; rubber seal 15ms or less , Ambient and fluid temperature: -10 to 50C, VALVE, BODY PORTED (DC), VALVE, VQZ100 VALVE, SOL 3-PORT, UA, VQZ100 BUILT

Series AN is available with M, R or NPT threads. Fluid: compressed air, Noise reduction: 25-35 dB(A) or more, Maximum operating pressure: 1.0MPa, Effective area mm 2 (Cv): AN*00 35-960 (1.9-53); AN*02 35-90 (1.9-5.0); AN*03 10-60 (0.6-3.3), Ambient and fluid temperature: 5 - 60 C, PLUG CONNECTOR ASSY, VQ100, VALVE, VQ1000 NO SIZE RATING, .03850 lb

KQ fittings are available to order in multiples of 10.The current KQ series fitting has been discontinued. SMC has introduced an improved version of KQ2 series, and recommends that you utilize the new series for your product designs.

KQ fittings are available to order in multiples of 10.The current KQ series fitting has been discontinued. SMC has introduced an improved version of KQ2 series, and recommends that you utilize the new series for your product designs.

KQ fittings are available to order in multiples of 10.The current KQ series fitting has been discontinued. SMC has introduced an improved version of KQ2 series, and recommends that you utilize the new series for your product designs.