Size: 01(Size 26mm), Stations: 7 Stations, A, B Port: 03 (Side, 3/8), Port Thread: T (NPTF), SI Unit: SDQ (Serial Kit for DeviceNet™), End Plate: w/o SI Unit/End Plate, SI Unit COM: N (-COM), Number of Input Blocks: 0 (w/o Input Block), Type of Input Block: w/o Input Block, Input Block COM: PNP or w/o SI Unit/Input Block, Silencer: S (Direct Exhaust w/Built-in Silencer)
-color display (Red and green) Sampling cycle: 5 times/s Display PF2 2% F .S. 2 digit (at 25C ambient temperature) 2% F .S. 1 digit (at 25C ambient temperature) Display accuracy IF Light up when output is ON (Green) 2% F .S. or less (based on 25C) IP40 Operating: 0 to 50C, Stored: 10 to 60C (No freezing or condensation) Operating and stored: 35 to 85% RH (No condensation) 1000 VAC for 1 min
Flow Rate Range: 50 [1 to 50 (25 for CO2) â„“/min], Flow Adjustment Valve: S (Yes), Port Size: 01 (Rc1/8), Piping Entry Direction: Straight, Output Specification: 2 [Analog Output (4 to 20 mA)], Instruction Manual: With Instruction Manual, Calibration Certificate: A (w/Calibration Certificate), Connector: W [Lead Wire w/Connector (2m) + Rubber Cover], Option: V (Panel Mount Adapter for w/
Flow Rate Range: 10 [0.2 to 10 (5 for CO2) â„“/min], Flow Adjustment Valve: S (Yes), Port Size: 01 (Rc1/8), Piping Entry Direction: Straight, Output Specification: 2 [Analog Output (4 to 20 mA)], Instruction Manual: With Instruction Manual, Calibration Certificate: A (w/Calibration Certificate), Connector: W [Lead Wire w/Connector (2m) + Rubber Cover], Option: V (Panel Mount Adapter for w
Flow Rate Range: 25 [0.5 to 25 (12.5 for CO2) â„“/min], Flow Adjustment Valve: S (Yes), Port Size: 01 (Rc1/8), Piping Entry Direction: Straight, Output Specification: 2 [Analog Output (4 to 20 mA)], Instruction Manual: With Instruction Manual, Calibration Certificate: A (w/Calibration Certificate), Connector: W [Lead Wire w/Connector (2m) + Rubber Cover], Option: V (Panel Mount Adapter for
Type: 332 (Body Ported), Valve Option: W (For Low Wattage), Rated Voltage: 6 (12 VDC), Electrical Entry: H (Grommet, Lead Wire 600mm), Light/Surge Voltage Suppressor: S (w/Surge Voltage Suppressor), Port Size: 01 [Rc 1/8, (Base Mounted w/Sub-plate)], Thread: N (NPT), Bracket: F (w/Bracket, Not Assembled)
Stations: 01 (1 Station), Piping: D (U Side: Closed; D Side: Open), Thread Type: N (NPT), Supply Unit Components: S (w/Flow Adj. Valve; Stop Valve: None), Return Unit Flow Switch: 7 (Integrated Display), Return Unit Flow Range: 20 (2 to 16 L/min), Return Unit Components: P (w/o Flow Adj.
Stations: 01 (1 Station), Piping: D (U Side: Closed; D Side: Open), Thread Type: N (NPT), Supply Unit Components: S (w/Flow Adj. Valve; Stop Valve: None), Return Unit Flow Switch: 7 (Integrated Display), Return Unit Flow Range: 20 (2 to 16 L/min), Return Unit Components: P (w/o Flow Adj.
Type: 332 (Body Ported), Valve Option: W (For Low Wattage), Rated Voltage: 5 (24 VDC), Electrical Entry: G (Grommet, Lead Wire 300mm), Light/Surge Voltage Suppressor: S (w/Surge Voltage Suppressor), Port Size: 01 [Rc 1/8, (Base Mounted w/Sub-plate)], Thread: T (NPTF), Bracket: F (w/Bracket, Not Assembled)
Nil S n 12mm 16mm 20mm 25mm 2 pcs. 1 pc. "n" pcs.
P . 15-11-3 15-9-2 2 Speed Controller with One-touch Fitting Elbow Type/Universal Type Series AS How to Order 2 2 0 01 06 S AS 1F Nil Option Body size 1 2 3 4 M3, M5 standard 1/8, 1/4 standard 3/8 standard 1/2 standard None With seal Hexagonal lock nut Electroless nickel plated S K N If more than one option is required, write option part numbers in the order of S, K, N.
Rated Vacuum Range: F (-100.0 to 100.0 kPa), Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: Unit Selection Function, Piping Specification: 01 (R1/8)
Rated Vacuum Range: -100 to 100 kPa, Output Specification: PNP Open Collector 2 Outputs + Analog Current Output, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: R 1/8, Lead Wire: -, Bracket: -, Operation Manual: -
Rated Vacuum Range: -100 to 100 kPa, Output Specification: NPN Open Collector 2 Outputs + Analog Voltage Output, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: R 1/8, Lead Wire: -, Bracket: -, Operation Manual: -
Rated Vacuum Range: -100 to 100 kPa, Output Specification: PNP Open Collector 2 Outputs + Copy Function, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: R 1/8, Lead Wire: -, Bracket: -, Operation Manual: -
Rated Vacuum Range: -100 to 100 kPa, Output Specification: PNP Open Collector 2 Outputs + Analog Voltage Output, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: R 1/8, Lead Wire: -, Bracket: -, Operation Manual: -
Rated Vacuum Range: -100.0 to 100.0 kPa, Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: Unit Selection Function, Piping Specification: R1/8, Lead Wire: -, Bracket: -, Operation Manual: -
Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: V (PNP Open Collector 2 Outputs + Analog Current Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: 01 (R 1/8)
Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: R (NPN Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: 01 (R 1/8)
Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: Y (PNP Open Collector 2 Outputs + Copy Function), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: 01 (R 1/8)