SMC Corporation of America
Elite Part Number Search
Search Results "ZH05DSA-06-06-06N"

Nozzle Diameter: 07 (ø0.7mm), Vacuum Pressure: L (-48 kPa: ZH05 to 13D*A; -66 kPa: ZH15 to 20D*A), SUP: 06 (One-touch Fitting ø6), VAC: 01 (Screw-in Rc 1/8), EXH: 06 (One-touch Fitting ø6), Accessories: N (w/o Bracket, w/o Silencer)

Nozzle Diameter: 07 (ø0.7mm), Vacuum Pressure: S (-90 kPa), SUP: 06 (One-touch Fitting ø6), VAC: 01 (Screw-in Rc 1/8), EXH: 06 (One-touch Fitting ø6), Accessories: N (w/o Bracket, w/o Silencer)

Nozzle Diameter: 05 (ø0.5mm), Vacuum Pressure: L (-48 kPa: ZH05 to 13D*A; -66 kPa: ZH15 to 20D*A), SUP: 06 (One-touch Fitting ø6), VAC: 01 (Screw-in Rc 1/8), EXH: 06 (One-touch Fitting ø6), Accessories: N (w/o Bracket, w/o Silencer)

Nozzle Diameter: ø0.7mm, Vacuum Pressure: -48 kPa: ZH05 to 13D*A; -66 kPa: ZH15 to 20D*A, SUP: One-touch Fitting ø6, VAC: Screw-in Rc 1/8, EXH: One-touch Fitting ø6, Accessories: w/o Bracket, w/o Silencer

Nozzle Diameter: ø0.5mm, Vacuum Pressure: -48 kPa: ZH05 to 13D*A; -66 kPa: ZH15 to 20D*A, SUP: One-touch Fitting ø6, VAC: Screw-in Rc 1/8, EXH: One-touch Fitting ø6, Accessories: w/o Bracket, w/o Silencer

Main Body Shape: Pipe Type, Additional Function: -, Ultimate Vacuum(kPa): -90, Air Consumption Flow Rate(l/min): 27, Vacuum Port Connecting Port Shape: Rc1/8, Vacuum Port One-Touch Fitting Size: -, Air Supply Port Connecting Shape: One-Touch Couplings, Air Supply Port One-Touch Fitting Size: Ø6, Application: Manifolds, Operating Pressure Range(MPa): 0.1~0.6, Operating Temperature Range(°C

Lightweight, point-of-use ZH and ZU series vacuum generators combine design simplicity with high performance. Simply plug an air supply tube in one end, and vacuum is ready at the other end. The slim ZU generators are extra compact. The ZH and ZU immediate response may be quicker than central vacuum systems. Also, these generators are often smaller and lighter than the bulky vacuum lines

Lightweight, point-of-use ZH and ZU series vacuum generators combine design simplicity with high performance. Simply plug an air supply tube in one end, and vacuum is ready at the other end. The slim ZU generators are extra compact. The ZH and ZU immediate response may be quicker than central vacuum systems. Also, these generators are often smaller and lighter than the bulky vacuum lines

Refer to page P.8 for details. 11 Performance Curve Flow Rate Characteristics PA5010-04 PA5010-06 Selection from Flow Rate Characteristic Graph Required specifications example: Find the pilot air pressure and air consumption of pilot air for a discharge rate of 27 L/min and a discharge pressure of 0.25 MPa.

Refer to page P.8 for details. 11 Performance Curve Flow Rate Characteristics PA5010-04 PA5010-06 Selection from Flow Rate Characteristic Graph Required specifications example: Find the pilot air pressure and pilot air consumption for a discharge rate of 15 L/min and a discharge pressure of 0.14 MPa.

ALARM01 Water Leak Detect FLT 01 ALARM03 RFGT High Press FLT 03 ALARM04 CPRSR Overheat FLT 04 ALARM05 Reservoir Low Level FLT 05 ALARM06 Reservoir Low Level WRN 06 ALARM07 Reservoir High Level WRN 07 ALARM08 Temp. Fuse Cutout FLT 08 ALARM09 Reservoir High Temp. FLT 09 ALARM10 Return High TempWRN 10 ALARM11 Reservoir High Temp.

G 1/4 (ND7100), 1/4 NPT (ND7200). 06 High capacity. Stroke volume of actuator > 3 dm3. G 1/4 (ND7100), 1/4 NPT (ND7200). T 5. COMMUNICATION / INPUT SIGNAL RANGE ND7_HXT, ND7_HZT: II 3 G Ex nA IIC T6...T4 Gc II 3 D Ex tc IIIC T90 C Dc Ui 30 V, Ii 152 mA H 420 mA, HART communication. Supply voltage 30 V DC.

Silencer Compact resin type Metal body type High noise reduction type Part Part number number AN20-02 AN30-03 AN40-04 AN500-06 AN600-10 AN202-02 AN302-03 AN402-04 ANA1-06 ANA1-10 Piping size 1/4 3/8 1/2 3/4 1 1/4 3/8 1/2 3/4 1 AMA20#-##C-#-#L# NC AMA20#-##D-#-#L# NO AMA30#-##C-#-#L# NC AMA30#-##D-#-#L# NO AMA40#-##C-#-#L# NC AMA40#-##D-#-#L# NO AMA60#-##C-#-#L# NC AMA60#-##D-#-#L# NO -147No.PF-OMA1007